Introduction

Molecular spectroscopy dates back to Newton’s division of sunlight into a color bar from red to violet using a prism. With the advent of quantum mechanics and lasers, the precise spectral analysis method has developed rapidly in many fundamental domains, with applications ranging from the quantum description of the matter to non-intrusive diagnostics of various media. On the one hand, accurate and sensitive spectroscopic absorption measurements are achieved in the laboratory via different methods, such as cavity ring-down spectroscopy1, intracavity laser absorption spectroscopy2, and optical comb spectroscopy3,4 (Michelson-comb spectroscopy5, dual-comb spectroscopy6,7,8, and Ramsey-comb spectroscopy9). On the other hand, greenhouse gases and atmospheric pollutants are monitored in the atmosphere by various techniques, such as grating spectrometers10, Fourier transforms spectroscopy11,12,13, and differential optical absorption spectroscopy14,15. As an example, dual-comb spectroscopy is applied for spectra analysis in a high-finesse optical cavity7, and in an open path between a telescope and retroreflectors installed at different ranges16,17. The approaches mentioned above provide either in-situ or column-integrated spectral information. However, molecular characteristics vary rapidly in time and space due to chemical reactions and physical transportation in free atmosphere. It would be beneficial to analyze the processes continuously with range-resolved spectra in open areas, especially in inaccessible regions.

Lidar techniques sense three-dimensional distributions of molecules remotely18,19. Raman scattering lidar and differential absorption lidar (DIAL) are two representative lidar techniques. The former is based on the inelastic Raman scattering with several orders of magnitude lower efficiency than that of elastic scattering, which is appropriate for measuring molecules with high concentrations20. The latter emits two lasers at different frequencies alternatively. The intensity of laser at online frequency is strongly absorbed by the molecule under investigation, and that at nearby offline frequency is weakly absorbed21,22. The two-frequency DIAL is optimized for specific molecule detection thus not suitable for multi-gas analysis, lacking the full information of different gas absorption lines. Instead of acquiring the differential absorption in two frequencies, multi-frequency DIAL obtains the entire absorption spectrum by emitting laser pulses at dozens of frequencies, where frequency accuracy is a challenge. Frequency-locking techniques are demonstrated, including gas cell-referenced scanning lasers23,24, phase-locked laser diodes25, and frequency-agile optical parametric oscillators26. Usually, the integral spectra along the optical path are obtained in these multi-frequency DIALs, at the sacrifice of range resolution.

Here, photon-counting distributed free-space spectroscopy (PDFS) is proposed based on lidar techniques. Range-resolved optical spectrum analysis is achieved along the outgoing laser beam. In order to realize wideband frequency scanning and locking in lidar for the analysis of multiple gases spectra, the comb-referenced locking method27,28,29 is preferred rather than the traditional gas cell-referenced locking method23,24. Firstly, the frequency of an external cavity diode laser (ECDL) is stabilized by locking it to an optical frequency comb via heterodyne detection. Secondly, to suppress the fluctuation in coupling efficiency of telescope caused by turbulence, a superconducting nanowire single-photon detector (SNSPD) with a large-active area is manufactured. The SNSPD, with high detection efficiency, low dark noise, and broadband response is a promising detector for infrared remote sensing30,31,32,33,34. Thanks to the high signal-to-noise ratio (SNR) offered by the SNSPD, one can implement range-resolved spectrum analysis over a large optical span (~100 nm), using a low-power fiber laser. Thirdly, during the time-consuming detection process (usually a few minutes, since photon accumulation is used to enhance the SNR), aerosol loading variation, detector efficiency drift, and laser power fluctuation may introduce unexpected errors. To deal with these problems, a reference laser at a fixed frequency or a scanning probe laser fires alternately (employing time-division multiplexing technique), implementing differential absorption detection at each scanning step. Therefore, the laser pulses share the same acoustic-optical modulator (AOM), amplifier, telescope, optical path in space, SNSPD, and electric circuits, making the optical layout simple and robust thus free of repeated calibration. In other words, the proposed system can be regarded as an integrated system of dozens of two-frequency DIALs. It naturally holds much potential for greenhouse gas monitoring, leakage warning, and atmospheric chemistry researches.

The concentration of carbon dioxide (CO2) in the atmosphere has increased rapidly since the industrial age. Accurate assessment of carbon dioxide emissions is important to project future climate change35. At present, the carbon emissions peak and carbon neutrality are among the most concerning topics of discussion worldwide. Here, multi-dimensional analyses of atmospheric CO2 and HDO are demonstrated, which means one can analyze the gas in the time-range-spectrum domain in free atmosphere. By combining the analyses with real-time meteorological conditions, the continuous diurnal variation of CO2 and HDO over time, as well as the carbon capture capability of plants over range can be clearly observed.

Results

Principle and experimental set-up

In the selection of a suitable absorption line for CO2, the temperature insensitivity and the strength of the gas absorption line are key factors that influence the precision and sensitivity of the measurement36,37. The CO2 R16 line at 190.667 THz shows temperature insensitivity with a ground state energy of 106.130 cm−1 and a relatively higher line strength of 1.779 × 10−23 cm−1/(molecule cm−2) than other CO2 lines in the C and L bands38. An optical spectrum range of 190.652–190.682 THz is chosen, which covers the CO2 R16 line and also contains two weak semi-heavy water (HDO, isotopic water vapor) lines (Fig. 6b). The detailed analysis of absorption line selection is provided in Supplementary information.

A diagrammatic view of PDFS is shown in Fig. 1. A tunable ECDL (Toptica, CTL1550) covering 185.185–196.078 THz is used as a probe laser. One percent of the probe laser is split out and combined with an optical frequency comb for heterodyne detection, offering an accurate frequency reference when tuning the frequency of the probe laser (for details, see Fig. 6 in the section “Materials and methods” section). The other 99% of the probe laser and a reference laser (Rayshining, PEFL) are chosen alternatively by using a fast optical switch (OS) and chopped into laser pulses via an AOM, with a pulse repetition rate of 20 kHz and a full width at half maximum (FWHM) of 400 ns. The pulse energies of chopped pulses are amplified via an erbium-doped fiber amplifier (EDFA) to 40 μJ. Such an optical layout ensures that the probe pulse and the reference pulse have exactly the same shape. The time sequence of time-division multiplexing is shown in Fig. 1c, where the probe pulse is tagged in odd numbers (1, 3, 5, etc.) and the reference pulse is tagged in even numbers (2, 4, 6, etc.). Then, the laser pulses are pointed to the atmosphere through a collimator with a diameter of 100 mm. The probe laser scans the CO2 and HDO absorption spectra, while the reference laser remains at a stable frequency of 190.652 THz. At each scanning step, the atmospheric backscattering signals at probe frequency and reference frequency are received and coupled into an optical fiber with a core diameter of 50 μm using a telescope with a diameter of 256 mm. Two multimode fiber (MMF) bandpass filters (37 GHz flattop bandwidth) are cascaded to suppress the solar background noise in the daytime, with a total suppression ratio of 60 dB. Finally, the signal is fed to the large active-area SNSPD. The SNSPD is divided into 9 pixels, and each pixel consists of two superconducting nanowire avalanche photodetectors, which improves the maximum count rate of the detector. The total quantum efficiency of the SNSPD array is 31.5% at 190.667 THz, and the dark count rate is below 100 per second. The count rate of the detector reaches 20 MHz with quantum efficiency higher than 30.0%. The SNSPD works in its linear operating range since the count rate is below 7 MHz in the experiment.

Fig. 1: Optical layout.
figure 1

a Experimental set-up. The detailed parameters of the instruments are listed in Table S2. BD balanced detector, OS optical switch, AOM acousto-optic modulator, EDFA erbium-doped fiber amplifier, SNSPD superconducting nanowire single-photon detector, MCS multi-channel scaler, PM polarization-maintaining, MM multi-mode. b Light propagating in the atmosphere. The path length in the red sections represents the range resolution of ∆R, and the spectra within this range in the whole free space can be obtained. c Time sequence of the time-division multiplexing technique

The atmospheric backscattering contains Mie and Rayleigh components. Note that Rayleigh scattering is inversely proportional to the fourth-order of the wavelength (~1572 nm). Thus, Mie backscattering dominates in the raw lidar signal. The photon number received in the frequency of ν and at a range of Rj is expressed as18

$$N\left( {\nu ,R_j} \right) = \frac{E}{{h\nu}}\eta _{\rm {o}}\eta _{{{\mathrm{q}}}}\frac{{A_{{{\mathrm{t}}}}}}{{R_j^2}}O\left( {R_j} \right)\frac{{c\tau }}{2}\beta \left( {\nu ,R_j} \right)T_{{{\mathrm{r}}}}^2\left( {\nu ,R_j} \right)$$
(1)

where E is the pulse energy, ηo is the optical efficiency of the transmitted signal, ηq is the quantum efficiency, h is the Planck constant, At is the area of the telescope, Rj is the range, j represents the index of range, O(Rj) is the geometrical overlap factor, c is the speed of light, τ is the pulse duration, and β is the Mie volume backscattering coefficient. The range resolution ΔR = /2 is limited by the laser pulse duration. The transmission term Tr is given by

$$T_{{{\mathrm{r}}}}\left( {\nu ,R_j} \right){{{\mathrm{ = }}}}\exp \left\{ { - {\int}_0^{R_j} {\left[ {\alpha _{{{\mathrm{a}}}}\left( {\nu ,R_j} \right) + \alpha _{{{\mathrm{m}}}}\left( {\nu ,R_j} \right)} \right]{{{\mathrm{d}}}}r} } \right\}$$
(2)

where αa is the extinction coefficient of aerosol including the effects of scattering and absorbing. αm = αg + αs is the extinction coefficient of molecules, where αg is the absorption coefficient of the gas under investigation, and αs represents other extinction processes of molecules.

The received photon number in the probe frequency νi (i = 1, 2,…, 30 being the index of the frequency steps) and the reference frequency ν0 is Ni(νi, Rj) and N0(ν0, Rj), respectively. Since the reference frequency ν0 is close to the probe frequency νi, it is assumed that in Eqs. (1) and (2), β, αa, and αs, have the same values. Furthermore, the probe and reference lasers share the same AOM, amplifier, optical path, SNSPD, and electric circuits. After EDFA gain and optical response correction against frequency, the only difference between Eqs. (1) and (2) is the absorption coefficient αg of the gas under investigation. Thus, the total differential optical depth (DOD) for a single optical path is estimated as

$$\begin{array}{l}{\mathrm{DOD}}\left( {\nu _i,R_j} \right) = - 0.5\ln \left[ {N_i/N_0} \right]\\ {{{\mathrm{ }}}} = {\int}_0^{R_j} {\left[ {\alpha _{{{\mathrm{g}}}}\left( {\nu _i,R_j} \right) - \alpha _{{{\mathrm{g}}}}\left( {\nu _0,R_j} \right)} \right]{{{\mathrm{d}}}}r} \end{array}$$
(3)

and the DOD within a range cell (ΔDOD) from Rj to Rj+1 is expressed as

$${\Delta}{\mathrm{DOD}}(\nu _i) = {\mathrm{DOD}}\left( {\nu _i,R_{j + 1}} \right) - {\mathrm{DOD}}\left( {\nu _i,R_j} \right)$$
(4)

which corresponds to the range-resolved absorption spectrum over the frequency scanning range. As illustrated in Fig. 1b, the absorption spectra of gases in any distributed cell along the laser beam can be obtained.

The number of received photons is stochastic in nature because of the random photon arrival and annihilation time in this quantum-limited detection19. The photon counts follow the Poisson distribution and the shot-noise is the mean square of the photon counts. Thus, the SNR can be described as N1/2. According to Eq. (1), a higher pulse energy E and a larger effective telescope area At are usually used to improve the SNR. Here, higher coupling efficiency contained in ηo, higher quantum efficiency ηq, and lower dark noise is realized by using a large active-area SNSPD. In addition, the influence of atmospheric turbulence is suppressed by using this SNSPD with an active-diameter of 50 μm39.

Data acquisition and processing

In previous work, the frequency locking technique and SNSPD with large active-area are introduced. And, the influence of HDO on CO2 is studied theoretically and compared experimentally in summer and winter40. Here, to carry out a continuous, stable, and long-range field experiment, the influence of aerosol variation, laser power fluctuation, detector instability, and signal coupling efficiency instability due to turbulence is compensated for in the data acquisition and processing process, as shown in Fig. 2.

Fig. 2: Flow chart of data acquisition and processing.
figure 2

to represent step 1 to step 7. P pressure, T temperature

Step 1: The backscattering profiles of the probe laser at different scanning steps and the reference laser at 190.652 THz are collected as photon counts Ni(νi, Rj) and N0(ν0, Rj), respectively.

Step 2: Ni(νi, Rj) are calibrated as Ni(νi, RjG(νiHr(νi), considering the non-uniform optical gain of the EDFA G(νi) and the optical response Hr(νi) over the scanning span.

Step 3: The aerosol variation, laser power fluctuation, detector instability, and signal coupling efficiency instability due to turbulence are calibrated by Ni(νi, RjG(νiHr(νi)/N0(ν0, Rj). Thus, a matrix of DOD(νi, Rj) containing integrated absorption spectra of CO2 and HDO along the optical path from 0 to Rj is obtained.

Step 4: The range-resolved absorption spectra ΔDOD at the range R = (Rj + Rj+1)/2 with range resolution of ΔR = Rj+1Rj are calculated by DOD(νi, Rj+1)−DOD(νi, Rj), where i changes from 1 to 30.

Step 5: Triple-peak Lorentzian nonlinear fitting is performed to separate the spectra of CO2 and HDO. Numerical least-squares optimization of the Lorentzian function is achieved by Levenberg–Marquardt method. Several database-based a priori constraints, including the relative strength of two HDO lines, relative frequency offsets between peaks, and the FWHM calculated with in-situ atmospheric temperature and pressure, are used in the fitting process (details are appended in the “Materials and methods” section).

Step 6: The area A of each separated spectrum and its standard deviation are obtained as the fitting results. Both CO2 and HDO concentrations and their precisions are determined by calculating the areas of the fitted spectra according to Eqs. (7)–(9).

Step 7: Concentrations are compared to the results from in-situ measurements for validation. The standard deviations between the comparisons are determined by counting the residuals of the measurements.

The raw backscattering signals of the probe light Ni(νi, Rj) and the reference light N0(ν0, Rj) are shown in Fig. 3a, b, respectively. The CO2 absorption feature is clear around the center frequency of Ni(νi, Rj) at ~190.667 THz. From step 1 to step 3, the spectra of total optical depth DOD(νi, Rj) integrated over different ranges can be obtained, as shown in Fig. 3c. Then, in step 4, PDFS acquires the range-resolved spectra at different range cells. Fig. 3d illustrates one example of ΔDOD, at 4 km with a range resolution of 60 m. After step 5, the CO2 and HDO lines are separated by Lorentzian nonlinear fitting. Note that, the concentration of HDO varies with atmospheric temperature at different seasons, with a lower value in winter than that in summer40.

Fig. 3: Backscattering signals and spectra.
figure 3

a The probe signal, with 30 scanning frequencies, covers CO2 and HDO absorption lines. b The reference signal without gas absorption. c The total optical depth spectra of CO2 and HDO at different ranges. d Lorentzian fitting of the range-resolved spectra; magenta dots are the measured ∆DOD values at 4 km with ∆R = 60 m

Continuous observation

Continuous field observation is carried out on the top of a building at the University of Science and Technology of China (USTC) (31.83°N, 117.25°E). To compare the results with in-situ sensors conveniently, the laser beam is emitted horizontally at a height of 50 m above ground level. In-situ CO2 analyzer (Thermo Scientific 410i) and humidity analyzer (Vaisala WMT52) are placed at the same height and 2 km away from the PDFS system in the laser path. The retrieved concentrations plotted versus range and time are shown in Fig. 4. The range resolution is 60 m, and the time resolutions for CO2 and HDO are 10 and 30 min, respectively. The measurement errors for both CO2 and HDO increase with the detecting range (Fig. 4a, b), due to SNR decaying along the range. And both concentrations of CO2 and HDO show good consistency with the results of the in-situ analyzers (Fig. 4c, d). The errors of HDO are larger than those of CO2, due to sparse frequency sampling and weak absorption of HDO over the optical frequency span. The averaged retrieval precisions at 2 km are ±5.4 and ±0.9 ppm, corresponding to ±1.2% and ±14.3% for the ambient concentration levels of CO2 and HDO, respectively. The comparisons between the in-situ analyzers and the PDFS measurements are plotted in Fig. 4e, f. The standard deviations of CO2 and HDO are ±9.6 and ±0.7 ppm, corresponding to ±2.1% and ±10.6%, respectively.

Fig. 4: Comparisons and error analysis.
figure 4

a The range plot of CO2 concentrations at 6:00 on September 27, 2020, with a range resolution of 60 m. b The range plot of HDO concentrations. c The time plot of CO2 concentrations at 2 km, with a time resolution of 10 min. d The time plot of HDO concentrations, with a time resolution of 30 min. e Correlation between PDFS and Thermo Scientific 410i for CO2 measurements, with a standard deviation of ±2.1%. f Correlation of HDO measurements, with a standard deviation of ±10.6%. Shaded ranges and error bars indicate the 1σ standard deviation

Fig. 5a, b show the horizontal range-time distributions of the concentrations of CO2 and HDO measured by PDFS over 72 h. CO2 is unevenly distributed along with the range, affected mainly by the distribution of vegetation. Especially, in the ranges of 1.2–2.5 and 4.0–4.5 km, the CO2 concentration shows some lower marks during the daytime, which are caused by the photosynthesis of plants in the parks there. Beyond that, the CO2 and HDO concentrations show diurnal variation trends along the time and fluctuation along the range with fence-like patterns. Many factors may contribute to these phenomena, such as dissipation caused by turbulence, atmospheric transport, human activities, industrial production, etc. Thus, other instruments are employed to monitor the wind field and turbulence for further verifications.

Fig. 5: Results of continuous observation.
figure 5

Range-time plots of a CO2, b HDO. Height-time plots of c CNR, d Horizontal wind speed, e Horizontal wind direction, f Turbulent kinetic energy dissipation rate (TKEDR). g CO2 concentration and \(C_{{n}}^2\). The black line represents the CO2 concentration at 2 km measured by PDFS. The red line is \(C_{{n}}^2\) measured by a scintillometer, with the y-coordinate reversed. h Relative humidity (RH) and temperature (tem.) The magenta dotted line represents the RH at 2 km. The blue dashed line represents the temperature measured by Vaisala WMT52, with the y-coordinate reversed

A coherent Doppler wind lidar (CDWL) is used to monitor local meteorological conditions. The results are shown in Fig. 5c–f. The carrier-to-noise ratio18 (CNR, defined as the ratio of the mean radio-frequency signal power to the mean noise power) reflects the backscattering signal intensity from an aerosol. Fig. 5c shows that there are rarely external transmissions and no sudden fall of aerosol. In addition, Fig. 5d, e provides the horizontal wind speed and horizontal wind direction. It is noteworthy that the horizontal wind speed in the near ground region is <5 m/s, and the wind direction is mainly easterly. Considering that there is no industrial area in the east of the campus, the relatively stable wind field shows that CO2 and HDO are hardly affected by external transmission. The turbulent kinetic energy dissipation rate (TKEDR)41 in Fig. 5f shows that the local turbulence of the atmosphere is strong during the daytime. The diurnal variation of turbulence dominates the gas concentrations near the ground.

Fig. 5g shows the CO2 concentrations at 2 km measured via PDFS and the near-ground atmospheric refractive index structure constant \(C_{{n}}^2\) measured by a large-aperture scintillometer (Kipp & Zonen LAS MKII). The scintillometer is placed on the top of a building with a height of 50 m, and its transmitter and receiver are located at a range of 1.1 and 2 km from the PDFS. For the convenience of readers, the y-coordinate of \(C_{{n}}^2\) in Fig. 5g is reversed. During the continuous observation, the turbulence intensity gradually increases every morning from 8:00 to 12:00. Meanwhile, the CO2 concentration dissipates rapidly. Then, the turbulence intensity decreases in the afternoon and remains weak during the night, whereas the CO2 concentration accumulates gradually. On the one hand, the correlation between the turbulence intensity and the concentration of CO2 is shown clearly. The CO2 shows a diurnal variation along with the trend of \(C_{{n}}^2\) throughout the whole observation time. On the other hand, there is a time delay between the trends of concentration and turbulence intensity, especially during the morning. Within the range of several kilometers, usually, the resolution of satellite payload equipment, the concentrations of CO2 and HDO change almost simultaneously. On the time scale, they are mainly affected by the atmospheric conditions of the boundary layer, especially the turbulence. Figure 5h shows the opposite trend in terms of the variation of relative humidity (RH) as measured by PDFS and the temperature measured by the in-situ sensor (Vaisala, WMT 52), where the y-coordinate of temperature is also reversed. The RH is retrieved from the measured HDO concentration using an empirical relative abundance between H2O and HDO. The natural abundance of H2O and HDO are 0.997317 and 0.000311, respectively38.

Discussion

In conclusion, a PDFS method has been proposed and demonstrated for the remote sensing of multi-gas spectra at different locations over 6 km. To obtain precise spectra during scanning for open-path measurements, a stabilized probe laser frequency is provided by locking it to the optical comb. A reference laser is alternatively emitted with the probe laser using the time-division multiplexing technique, reducing the influences of aerosol variation, laser power fluctuation, detector instability, and telescope coupling efficiency change. Moreover, an SNSPD with a large active area, wideband response, and low dark noise is employed for long-range detection, making wideband PDFS possible with a low-power fiber laser. With further development, PDFS can be updated to measure the distributed spectra over C and L bands, so that abundant gases, such as CO, CO2, H2O, HDO, NH3, and C2H2 can be analyzed within a single system (Table S1). Future applications of PDFS include long-range warnings of flammable, explosive and toxic substances, and monitoring of industrial pollution. Furthermore, substance evolution and chemical reactions in the atmosphere can be further investigated.

Materials and methods

The principle of comb-referenced frequency locking

Figure 6 shows the principle of comb-referenced frequency scanning and locking technique40. The probe ECDL is tuned by controlling its piezo-electric transducer (PZT). The hysteresis loops of voltage versus relative optical frequency are shown in Fig. 6a. Different colors of loops represent different dynamic ranges of the PZT. In the scanning range of 190.652–190.682 THz, one CO2 absorption line and two weak HDO lines are found in a ground-level atmosphere condition according to HITRAN 2016 (ref. 38). As shown in Fig. 6b, the frequency in the x-coordinate is relative to the center frequency 190.667 THz of the CO2 absorption feature. The 30 orange hollow circles represent the non-uniform frequency steps, which are used to sample the mixture spectrum. Denser frequency steps are used in the CO2 line for better precision in the measurement of CO2, making HDO an additional result. It is worth noting that the measurement precision of HDO can be improved by changing the scanning numbers and intervals (different frequency sampling modes are shown in Fig. S4).

Fig. 6: Principle of comb-referenced frequency-locking technique.
figure 6

a The hysteresis loops show the mapping between frequency and voltage of the probe laser. The lines in different colors show the loops for controlling voltage in different ranges. b The absorption functions of CO2 and HDO from HITRAN. The hollow circles represent the frequency steps used to sample the whole line shape. c The relative optical frequency variation versus time. d The beat frequency variation versus time. The locking process is shown in the flat lines, and the tuning process is shown in the triangle-wave-like track. e The probe laser νi beats with the optical comb νn, mapping optical the frequency into radio frequency signals. f Detailed description of the tuning process. As the probe laser beats with the nearest frequency comb teeth one by one, the beat frequency νb varies according to a triangle-wave-like track

The frequency of the probe laser (νi) is locked to the comb through a feedback locking loop27,28. As shown in Fig. 1, an optical frequency comb with a repetition rate νr = 100 MHz and carrier-envelope offset frequency νceo = 20 MHz are referenced to a rubidium clock. A tiny portion (~1%) of the probe laser and the comb are coupled into a balanced detector. The beat frequency between the probe laser and the nearest frequency comb tooth is selected by using a low-pass filter (LPF) with a bandwidth of 48 MHz, which is slightly lower than half of the repetition rate of the comb (100 MHz). Then the filtered beat frequency is read via a frequency counter (Keysight 53230A) and recorded on the computer. In the locking process (Fig. 6c, d), the beat frequency (νb) is compared with a reference frequency of 20 MHz, then the difference frequency signal is fed back to adjust the voltage of the PZT in the probe laser. Finally, the probe frequency is locked to the comb tooth with an offset frequency of 20 MHz. Note that the comb is a stabilized frequency ruler (νceo reaches frequency stability of 1.2 × 10−9 in an integration time of 1 s), the fluctuation of the beat frequency is dominated by the uncertainty of the probe frequency. The standard deviation of the locked probe frequency is 0.5 MHz in an integration time of 120 s. During the tuning process, the relative frequency of the probe laser ramps with time (Fig. 6c). As shown in Fig. 6e, f, the probe laser beats with the nearest frequency comb teeth one by one in the frequency domain, generating a triangle-wave-like track for the beat frequency. The peak beat frequency of the triangle-wave-like track is restrained in νr/2 using the LPF. While the probe laser scans from one comb tooth to another adjacent tooth, the beat frequency goes through one period. Thus, the absolute frequency interval between the frequency steps can be calculated from the track of the recorded beat frequency. The minimum frequency interval is limited by the repetition frequency of the comb.

Triple-peak Lorentzian nonlinear fitting

Since the experiment is carried out near the ground, we can assume that the Doppler line shift is negligible36,42. Therefore, a Lorentzian line shape can be used to fit the obtained spectrum. The Lorentzian model can be expressed as

$$\varphi \left( \nu \right) = \frac{{2A}}{\pi }\frac{{\omega _{{{\mathrm{L}}}}}}{{\omega _{{{\mathrm{L}}}}^2 + 4\left( {\nu - \nu _{{{\mathrm{c}}}}} \right)^2}}$$
(5)

where A = Lπ/2 is the area of Lorentzian line shape, H represents the height of the line center, νc is the center frequency of probe laser, and ωL is the FWHM, which is determined by36

$$\omega _{{{\mathrm{L}}}} = 2\gamma _0\left( {\frac{P}{{P_0}}} \right)\left( {\frac{{T_0}}{T}} \right)^{n_{\mathrm {t}}}$$
(6)

here P and T are the ambient pressure and temperature, γ0 is the pressure broadening coefficient at P0 = 1 atm and T0 = 273 K, and nt is the temperature exponent. The mixture line shape of CO2 and HDO is the superposition of three Lorentzian models, the independent line shape of each molecule can be obtained by performing a triple-peak Lorentzian fitting. Meanwhile, the fitted Lorentzian area of the range-resolved differential absorption depth can be expressed as

$$A = \mathop {\int}\limits_{{\mathrm {line}}} {{\Delta}{\mathrm {DOD}}\left( \nu \right)} {{{\mathrm{d}}}}\nu = S\left( T \right)N_{{{\mathrm{d}}}}L$$
(7)

where L is the length of the range cell, Nd is number density, and S(T) is the spectral line intensity which can be written as36

$$S\left( T \right) = S_0\left( {\frac{{T_0}}{T}} \right)^{3/2}\left\{ {\frac{{1 - \exp \left[ {hc\nu _{{{\mathrm{c}}}}/k_{{{\mathrm{B}}}}T} \right]}}{{1 - \exp \left[ {hc\nu _{{{\mathrm{c}}}}/k_{{{\mathrm{B}}}}T_0} \right]}}} \right\} \times \exp \left[ {\frac{{E^{\prime\prime}hc}}{k}\left( {\frac{1}{{T_0}} - \frac{1}{T}} \right)} \right]$$
(8)

here S0 is the line strength at P0 = 1 atm and T0 = 273 K, h is the Planck constant, c is the speed of light, kB is the Boltzmann constant, E″ is the lower-state energy. By combining Eqs. (5)–(8), the concentration (χ) of the molecule under investigation is retrieved as

$$\chi = \frac{A}{{S\left( T \right)Ln_{{{\mathrm{L}}}}}}\frac{{P_0}}{P}\frac{T}{{T_0}} \times 10^6$$
(9)

where nL = P0/(kB·T0) = 2.688256 × 1025 molecule/m−3.