Abstract
This study aimed to develop a deep learning (DL) algorithm for automated detection and localization of posterior ligamentous complex (PLC) injury in patients with acute thoracolumbar (TL) fracture on magnetic resonance imaging (MRI) and evaluate its diagnostic performance. In this retrospective multicenter study, using midline sagittal T2-weighted image with fracture (± PLC injury), a training dataset and internal and external validation sets of 300, 100, and 100 patients, were constructed with equal numbers of injured and normal PLCs. The DL algorithm was developed through two steps (Attention U-net and Inception-ResNet-V2). We evaluate the diagnostic performance for PLC injury between the DL algorithm and radiologists with different levels of experience. The area under the curves (AUCs) generated by the DL algorithm were 0.928, 0.916 for internal and external validations, and by two radiologists for observer performance test were 0.930, 0.830, respectively. Although no significant difference was found in diagnosing PLC injury between the DL algorithm and radiologists, the DL algorithm exhibited a trend of higher AUC than the radiology trainee. Notably, the radiology trainee's diagnostic performance significantly improved with DL algorithm assistance. Therefore, the DL algorithm exhibited high diagnostic performance in detecting PLC injuries in acute TL fractures.
Similar content being viewed by others
Introduction
Thoracic and lumbar (TL) spine fractures are among the most common fractures, and not only the fracture morphology but also the posterior ligamentous complex (PLC) injury is considered to be very important in determining the patient's treatment1,2. In a previous study, it was reported that approximately 53% of acute TL spine trauma cases were accompanied by PLC injury3. TL fractures are often evaluated through the Thoracolumbar Injury Classification and Severity Score (TLICS), which includes PLC injury evaluation2,4. The PLC is a posterior structure that affects the stability of the vertebral fracture site and is composed of the supraspinous and interspinous ligaments, ligamentum flavum, and facet joint capsule4,5. Magnetic resonance imagining (MRI) has become the most frequently used modality due to its high sensitivity and accuracy in detecting PLC injuries4,5,6. On MRI, PLC injuries are best assessed in T2-weighted fat saturation sagittal scans5, with injury diagnosis based on the presence of disruption in structures showing low signal intensity (SI) or suspected injury-related high SI changes5,7,8. TLICS categorizes PLC injuries into intact, indeterminate, or injured based on the severity of these findings. However, it's important to note that high SI changes can include false positives, such as edema, leading to reports of high sensitivity but low specificity in MRI evaluations8,9. As a result, the radiologist's judgment in MRI-based PLC injury assessment is crucial and can significantly influence surgical decisions, as TLICS plays a pivotal role in determining whether a patient should undergo surgical treatment4.
The development of artificial intelligence (AI) technology has led to an increasing number of AI decision support systems to help to prevent or reduce radiologists burnout due to abundant imaging volume10,11,12,13. Deep learning (DL) technology has been applied by various studies in the radiologic diagnosis of TL fractures10,12,13,14,15,16,17. However, most of these used DL to detect TL fractures in radiography and computed tomography (CT) and their usefulness has been proven for segmentation and detection of fractures. However, few studies for DL of TL fractures are based on MRI. Specifically, no MRI-based DL study has focused on PLC injury of multiple anatomical structures.
Therefore, in this study, we aim to develop a DL algorithm for automated detection and localization of PLC injury in TL fractures on MRI and evaluate its diagnostic performance.
Methods
This study was reviewed after obtaining Institutional Review Board (IRB) approval from each human research ethics committee of two institutions (Hallym University Dongtan Sacred Heart Hospital IRB and Soonchunhyang University Bucheon Hospital IRB). The requirement for written informed consent from the study subjects was waived by the IRB of Hallym University Dontan Sacred Heart Hospital and Soonchunhyang University Bucheon Hospital due to the retrospective study design. All the methods of this study were performed in accordance with the relevant guidelines and regulations.
Subjects (Supplementary Method 1)
Between January 2019 to December 2021, the image database contained 583 consecutive patients who underwent baseline thoracic or lumbar spine MRI after trauma and were diagnosing them with one or two continuous acute TL fractures. Exclusions were made based on specific criteria as shown in Figure 1. Ultimately, we included 400 patients with acute TL fractures, randomly divided into two groups: a training dataset of 300 patients (150 with PLC injury and 150 with normal PLC) and an internal validation dataset of 100 patients (50 with PLC injury and 50 with normal PLC). For external validation, we collected data from a different institution using different MRI scanners. The exclusion criteria of both external and internal validation datasets were identical, and 15 patients were excluded. Ultimately, the external validation set consisted of 50 TL fracture patients with PLC injury and another 50 TL fracture patients with normal PLC. Table 1 summarizes the demographic information of the patients.
Image acquisition
For the training and internal validation sets, all MRI scans, which included routine thoracic or lumbar spine MRI, were conducted with a 3.0 T unit (Skyra 3.0 T, Siemens, Erlangen, Germany) in this institution. For external validation set, 1.5 T MRI (Signa HDxt 1.5 T, GE Healthcare, Milwaukee, Wis, USA) was used. All spine MRI sequences included fat suppression (FS) using the Dixon technique T2-weighted image (WI) in the sagittal plane for trauma evaluation. And we used only one midline image of sagittal FS-T2WI for the training, internal and external validation sets. The specific spine MRI parameters of all scans in all datasets are presented in Supplementary Tables 1, 2.
Data collection and annotation
Spine MR images of training and test sets were reviewed by two musculoskeletal (MSK) radiologists with nine and 10 years of experience, respectively. Manual segmentation for each fractured vertebral body, background soft tissue anatomy (BA) including PLC above and below fractured vertebral body level, and injured PLC on sagittal FS-T2-WI was performed by one MSK radiologist with 10 years of experience using in-house software (DEEP:LABEL, DEEPNOID) (Supplementary Fig. 1).
DL algorithm development
In this study, the proposed DL system consisted of a two-step process after preprocessing of the input image: (1) segmentation and patch extraction, and (2) classification. To ensure that the DL model can perform segmentation and classification more efficiently, we performed image preprocessing in the order shown in the green box in Fig. 2. To preserve the proportions of the image, we performed zero padding and resized it to 384 × 384 (height x width). Thereafter, contrast was enhanced, and brightness was adjusted as a preprocessing to improve the automatic segmentation performance of the fractured vertebral bodies. In MRI images, the spine has specific features, such as constant shape and pixel value, but to find a vertebral body with an acute fracture, we need to find changes in image features, such as bone marrow edema. Therefore, the contrast of pixel values is an essential factor in determining whether a vertebral body has an acute fracture, and to improve it, we used the contrast limited adaptive histogram equalization (CLAHE) and the enhancement technique of gamma correction18,19. Min–Max Normalization was also applied during the preprocessing, and the preprocessed image described above became the input to the first DL architecture, and the next step, the segmentation task, was performed.
Segmentation and patch extraction
The DL architecture for segmenting acute vertebral body fracture and BA through preprocessed input images is shown in the yellow box in Fig. 2, and the detailed structure is shown in Fig. 3A. The DL algorithm used for training is Attention U-Net, which applies an attention mechanism to increase the concentration of features based on U-Net, the most commonly used segmentation algorithm in medical image segmentation20. This architecture applies attention gates to each skip connection in the decoder part of U-Net to emphasize the target feature, which improves segmentation performance. The following parameters were used for attention U-net: 200 epochs; batch size of 32; dropout rate of 0.05; group normalization with group size of 16; RMS Prop optimizer; learning rate of 0.0025; and learning rate decay of 0.99 every training step.
Post-processing of the predicted labels extracted through the segmentation task is performed in the order described in the purple box in Fig. 2. This post-processing is intended to reduce noise by removing all but the largest components of the TL fracture and BA predicted by the segmentation algorithm (Attention U-net), and utilizes the most reliably segmented components to extract patches as represented by the blue box in Fig. 2. This patch extraction was performed by cropping the image with a slight margin based on the location of the determined component. In the case of images where the fractured vertebral body and BA were not predicted at all, the entire image was processed as a patch. This final patch was then used as an input to the second DL architecture to perform the classification task of whether the PLC was injured or not.
Classification
This final extracted patch was also preprocessed to 256 × 256 by zero-padding and resizing as the original image, and the DL architecture that utilizes it as an input image to classify PLC injury is shown in the red box in Fig. 2, and the detailed structure is shown in Fig. 3B. The DL algorithm we used for training was Inception-ResNet-V221, which combines the strengths of Inception and ResNet by applying the concept of residual connections to the Inception V4 architecture. The outcome of the model is a binary result of whether the PLC is injured, and we used Gradient-weighted class activation mapping (Grad-Cam) to visualize in a heatmap which parts of the image the model used to make its judgment. The following parameters were used: 200 epochs; batch size of 16; dropout rate of 0.05; Adam optimizer; learning rate of 0.0001; and learning rate decay of 0.99 every training step (Fig. 3B). Additionally, we used data augmentation such as 15º rotation and gamma contrast (0.7–1.7). Because the injured PLC was small and due to the anatomical characteristics of these patches, other augmentation operations that included interpolation, flipping, and mirroring were not performed. The performance of the DL algorithm was investigated using internal and external validation datasets.
Comparison of the proposed DL system (two serial DL algorithms) with other DL algorithms.
To verify the superiority of the DL system proposed in this study, we conducted several comparative experiments on an external validation dataset. Through these comparative experiments, we can compare the performance of the backbone DL architecture used in each step with various other DL algorithms and explain the rationales for the backbone DL architecture settings of the proposed DL algorithm system. Furthermore, we eliminated two processes, segmentation task and patch extraction, and compared the PLC injury diagnosis performance of the classification algorithms on the original image (single classification algorithm result) with that of the proposed DL system (two serial DL algorithms) to validate the usefulness of the two processes.
Observer performance test
We conducted an observer performance test to investigate the diagnostic performances between the DL algorithm and radiologists. Two newly invited radiologists independently reviewed the images of the test set (the first session). One radiologist was an MSK radiologist (reader 1[R1]) had ten years of experience in radiology, including musculoskeletal radiology. Another radiologist was a trainee (reader 2[R2]) who had three years of experience in radiology, including MSK radiology. We did not involve the radiologists who defined the reference standard for the external validation dataset to participate in this test. Additionally, if there is a radiologist whose diagnostic performance is significantly lower than that of the DL algorithm or other radiologist, we evaluated whether the DL algorithm could improve the diagnostic performance of the radiologists after one-month washout period (the second session).
Statistical analysis
The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the DL algorithm and radiologists were analyzed. The area under the curve of the receiver operating characteristics (AUROC) analyses were also performed to compute the discriminating power of the DL algorithm and the two radiologists. To analyze the diagnostic performance between the DL algorithm and the reviewers, we compared the area under the curve using the Delong’s test. McNemar’s test was performed to compare the sensitivity and specificity of the DL algorithm with those of each of the two radiologists. McNemar's test was also used to compare the sensitivity and specificity of the radiologist with DL algorithm assistance and the radiologist without DL algorithm assistance. Statistical analyses were performed using R statistical software version 4.0.3 and MedCalc version 12.7 (MedCalc Software). In all analyses, a P < 0.05 was considered significant.
Results
Dataset
The clinical characteristics of the training and validation datasets are summarized in Table 1. The training dataset of 300 examinations for BA segmentation by Attention U-net included 150 patients in the normal PLC group (mean TLICS score, 1.78 ± 0.42; range, 1–2) and 150 in the injured PLC group (mean TLICS score, 4.22 ± 0.81; range, 2–8). The internal validation test of 100 examinations including 50 in the normal PLC group (mean TLICS score, 1.82 ± 0.39; range, 1–2) and 50 in the injured PLC group (mean TLICS score, 4.3 ± 0.80; range 3–7). The external validation dataset also consisted of 50 examinations with PLC injury (mean TLICS score, 1.59 ± 0.50; range 1–2) and 50 examinations without PLC injury (mean TLICS score, 4.29 ± 0.89; range, 3–7).
Diagnostic performance of the model
First step result (segmentation result of DL) of attention U-net
The Dice similarity coefficient of attention U-net in the first step were 0.849 for BA and 0.919 for fractured vertebral body in the internal test set and 0.773 for BA and 0.853 for fractured vertebral body in the external test set (Table 2). The proportion of attention U-net segmented BA containing the area of manual segmented BA were 99% (99/100 examination) in the internal validation test and 95% (95/100 examination) in the external validation test.
Second step result (detection of PLC injury) of inception-ResNet
The AUROC of the internal validation was 0.928. The sensitivity and specificity in the internal test set were 88.0% and 82.0%, respectively (Table 2). Six patients (two in the lumbar vertebral levels, one in the lower thoracic vertebral level, and three in the T12-L1 levels) with injured PLC were missed in the internal test set. The algorithm made nine false-positive detections in the internal test set; six had lumbar and three had thoracic vertebral fractures.
The AUROC of the external validation was 0.916. The sensitivity and specificity in the external test set were 82.0% and 94.0%, respectively. Nine patients (three in the lumbar, four in the lower thoracic, and two in the T12-L1 levels) with injured PLCs were missed in the external test set. The external test set had three false-positive detections of lumbar vertebral fractures (Table 2).
Comparison result of the proposed DL system (two serial DL algorithms) with other DL algorithms
Comparison of first step (segmentation) result of traditional U-net vs. Attention U-net
For the first DL algorithm comparison, we used the traditional U-net to validate the effectiveness of attention gate. The Dice similarity coefficient of the TL fracture and BA of the two segmentation algorithms (traditional U-net / Attention U-net) were 0.789/0.853 and 0.697/0.773, respectively. In other words, the segmentation results of the TL fracture and BA by traditional U-Net are approximately 6.4% and 7.6% lower than those of Attention U-Net, respectively.
Comparison of second step (classification) result of inception-ResNet-V2 vs. other classification algorithms
The classification performance was verified by comparing several deep learning models other than Inception-ResNet-V2, which was the second DL algorithm in the proposed DL system. The DL algorithms used in the comparison were Inception-ResNet-V2 (proposed DL algorithm), InceptionV322, Xception23, MobileNetV224, and EfficientNetB725, and the inputs used in this comparison process were all the same: the final image patches from the first (prepocessing of input image) and second processes (segmentation and patch extraction) of the proposed DL system. Additionally, in this process, the hyperparameters and data augmentation were set the same as the classification model of the proposed DL system. In terms of AUROC, the proposed model (Inception-ResNet-V2) performed the best with 0.916, followed by InceptionV3, EfficientNetB7, Xception, and MobileNetV2. In detail, the sensitivity was higher for InceptionV3 than for the proposed model. Nevertheless, InceptionV3 and other DL algorithms performed significantly worse than the proposed model on other diagnostic metrics, and the proposed model had the most stable performance when considering both normal and injured PLC classes (Table 3).
Comparison of classification performance between the single algorithm (without segmentation and patch extraction) and the two serial DL algorithm (proposed DL system)
We obtained the performance of the classification model without the two processes, segmentation task and patch extraction, the second step of the proposed DL system, to validate the effectiveness of the two processes. That is, it is an experiment that performs preprocessing on the original MRI image, but omits the segmentation task and patch extraction task and directly uses the classification model to classify PLC injuries. The deep learning architecture for the classification comparison was Inception-ResNet-V2, InceptionV3, Xception, MobileNetV2, and EfficientNetB7, and the hyperparameters and data augmentation were set the same as the classification model of the proposed DL system. The classification performance of each model on the external validation dataset is presented in Table 4. The highest performing model was InceptionV3 with an AUROC of 0.730, followed by Inception-ResNet-V2, MobileNet-V2, Xception, and EfficientNetB7. Nevertheless, all models performed worse in AUROC than the proposed DL system predicted by the input after segmentation and patch extraction, and even InceptionV3, which performed the best among the single algorithm results, had an AUROC of 18.6% lower than the proposed DL system.
Comparison between the DL algorithm and radiologists
In the first session of the observer performance test, the AUROCs for R1, and R2 were 0.930, and 0.830, respectively. There was no significant difference in the diagnostic performance of PLC injury between the DL algorithm and R1. However, the diagnostic performance of the DL algorithm tended to be higher (0.916) than that of R2 and was close to the statistically significant p value on Delong's test (p = 0.051). Furthermore, the diagnostic performance of R1 was higher than that of R2 (p = 0.011). The sensitivity and specificity of the two radiologists (R1/R2) were 92.0%/68.0% and 94.0%/98.0%, respectively. The accuracy of the two readers were 93.0% (R1) and 83.0% (R2). There was no significant difference between the algorithm and the two radiologists' diagnosis of PLC injury (p > 0.05). However, there was significant difference in the diagnosis of PLC injury between the R1 compared to R2 (p = 0.001). In the second session of observer performance test (R2 with DL-algorithm assistance), AUROC for R2 was 0.920. The increment of AUROC was 0.090 compared to the first session (p < 0.001). In terms of sensitivity, significant increment was shown (p = 0.006), while no significant difference of specificity (p > 0.999) was shown (Table 5 and Fig. 4).
Grad-CAM
Grad-CAM was also used to provide a visual explanation of the decision and make it more transparent to better understand the functionality of the deep neural network26. Several examples of Grad-CAM map are illustrated in Fig. 5 for normal PLC and injured PLC. For the injured PLC, the Grad-CAM map was confined to the injured PLC and background anatomical regions. In the normal PLC group, the Grad-CAM map was more widely distributed than in the injured PLC case and included the BA, vertebral body, and spinal canal. This Grad-CAM map suggested that the deep neural network in the second step was properly trained and that the important areas for imaging diagnosis are being monitored by inception-ResNet-V2.
In some cases, the classification algorithm in the second step was not affected by the BA segmentation (attention U-net) in the first step (Supplementary Fig. 2), while in other cases it was highly affected (Fig. 6). The inception-ResNet-V2 algorithm detected one injured PLC from one failed BA segmentation in the PLC injury group of the internal test set. Furthermore, the DL algorithm accurately classified one normal and three injured PLC cases from five (one normal and four injured PLC cases) failed BA segmentation cases in the external test set (Supplementary Fig. 2).
In the comparison of classification performance without segmentation and patch extraction and the proposed DL system, the single classification algorithm performed poorly compared to the proposed DL system (two serial DL algorithms), and to identify the reason for this, Grad-CAM was used to determine which part of the image was utilized by the DL algorithms to predict classification. As a result, unlike the proposed DL system, there were cases where the single classification algorithm failed to focus on the fractured vertebral body, which occupied a small area of the entire sagittal image (Fig. 6). Therefore, we inferred that the AUROC was relatively low because the single classification algorithm often based its predictions on locations unrelated to the TL fracture and PLC injury.
Discussion
This study is the first study on MRI-based PLC injury in TL fractures. Two-step training of the DL system was effective for the detection and classification of PLC injury showing AUROCs of 0.927 and 0.916 in the internal and external validation sets, respectively, which was similar to the performance of MSK radiologists. And we also revealed improvement in radiologist performance with the aid of the DL algorithms.
The reasons for this high diagnostic performance can be speculated as follows. First, in this study, BA including the PLC was segmented using Attention U-net, and the image range for finding features was dramatically reduced by patch extraction only around the segmentation. As shown in the single classification algorithm results, without the segmentation and patch extraction process in the first step, the performance was significantly reduced because the corresponding feature had to be detected at all spine levels included in the image. Therefore, the area that the DL algorithm should evaluate was reduced to BA above and below the vertebral body fracture, and then the features were extracted. Through the comparison of classification performance between the single algorithm and the two serial DL algorithms, we clearly confirmed that the first step significantly improved the performance of Inception-ResNet-V2 in the second step. Second, in the first step, the Attention U-net showed higher accuracy in terms of the Dice similarity coefficient compared to the traditional U-net. A previous study reported the attention gates in Attention U-net improve the sensitivity and accuracy for dense label predictions by suppressing feature activations in irrelevant regions20. Another study on lumbar spine MRI reported that the use of Attention U-net increased the accuracy of lumbar spine segmentation27. Similar to previous studies, our study showed that the fractured vertebral body and the BA segmentation results of the Attention U-net were superior to those of the traditional U-net. Third, the Inception-ResNet-V2 used in the second step is an algorithm that combines residual blocks with Inception previously developed by Google21,22,28,29. Due to this combination, the amount of memory and computation almost doubled compared to Inception V3, but it combined the advantages of ResNet, 'Compensating for the problem (Gradient Vanishing/Exploding, an increase in error due to an increase in the number of parameters) that occurs when the network is deep with residual connections'; thus, it has higher performance than the general Inception algorithm21. In our study, similar to previous studies, Inception-ResNet-V2 performed better in terms of AUROC compared to Inception V3. Inception-ResNet-V2 has been reported as a deep neural network with high accuracy in medical image classification30,31, and our study also showed high accuracy despite relatively few training cases.
The comparison between Inception-ResNet-V2 and other classification algorithms showed that Inception-ResNet-V2 had better diagnostic performance in terms of AUROC than other classification algorithms. Due to this, we selected Inception-ResNet-V2 as the backbone model for the classification task (second step). Notably, Efficient NetB7 had a slightly lower AUROC value than Inception V3 and Inception-ResNet-V2, despite being a more recently developed DL algorithm. The exact reason for this is unclear, but it is possible that the relatively small training data set in this study made it difficult to make accurate comparisons between models. Also, for DL algorithms with relatively complex compound scaling methods such as Efficient NetB725, it is possible that applying the same hyperparameters and data augmentation methods as applied to the Inception V3, Inception-ResNet-V2 algorithms may not be the most optimal method. This may require further research using more training data in the future study.
The algorithm developed in this study was also evaluated using an external dataset of images taken using different equipment from other MRI vendors in different hospitals. In the external validation dataset, unlike the internal dataset, the injured PLC group had a different gender distribution and mean age. Additionally, in the external dataset, the injured PLC group had more cases with two vertebral body fractures than one, compared to the injured PLC group in the internal dataset. This external validation suggested that the algorithm might be robust and effective for general use in real clinical settings.
The importance of PLC evaluation in TL fracture is well known, and the presence or absence of PLC injury is essential in surgical decision-making due to its effect on the stability of the fracture site1,2,32. Evaluation of PLC is mostly performed using MRI, and in most fracture patients, additional MRI is performed for PLC injury or neurological evaluation4,5,9. In determining surgical treatment, TLICS is commonly used by many clinicians because it reflects the spinal stability and the biomechanical mechanism of the spine4,33. The MRI-based evaluation of PLC injury depends more on the radiologist than on the evaluation of fracture morphology. It can be more difficult for a surgeon to assess a PLC injury using MRI than evaluate the TL fractures. Therefore, the role of the radiologist is even more important in the MRI-based evaluation of PLC injury. Inter- and intraobserver agreement on PLC injury was fair to moderate (0.389–0.616) among radiologists using MRI; radiologists possibly tend to over-recognize PLC conditions on MRI34 possibly because the subjective evaluation of MRI-based PLC injury and opinions may differ between surgeons and radiologists. Thus, in this context, the DL system proposed in our study has the potential to help radiologists in the consistent diagnosis of PLC injuries and surgeons in the evaluation of PLC injuries.
Until recently, studies using the DL system on TL spine fractures covered radiography and CT10,14,17,35,36. However, few studies on TL spine fracture using CT or MRI have been conducted. DL studies using MRI are limited because diagnosis is complicated and data collection is difficult because the segmentation of the anatomical structure of the spine must be the basis and fractures need to be diagnosed using multiplane imaging data. In particular, the PLC contains several ligamentous structures that complicate evaluation; most PLC injuries are in the interspinous or supraspinous ligament, and the most visible location is the spinous process, which is midline and visible on the sagittal plane. Therefore, in this study, the complicated process of data collection could be further simplified because the evaluation of the PLC was possible even if only one image was evaluated.
This study has some limitations. First, a small number of training datasets were used. In DL development, more accurate and sophisticated training is possible with more data. However, in our study, we were able to increase the diagnostic accuracy even though we used a small sample by using a two-step DL system. Second, PLC was evaluated with only one mid-sagittal image of MRI. However, most of the injuries were of the interspinous and supraspinous ligaments; in the absence of skipping in the mid-sagittal image, PLC evaluation was sufficient with only one image. Although there are limitations in assessing injuries to only the facet joint capsule or ligamentum flavum, these cases are extremely rare. Finally, false positives in the PLC evaluation are likely, such as due to interspinous bursitis at the lower lumbar level. However, considering that findings of interspinous bursitis also lead to disagreements in the diagnosis of PLC injury even among radiologists, this may be an inherent limitation of imaging diagnosis of PLC injury.
In conclusion, the DL algorithm detected PLC injury in patients with TL fracture with a high diagnostic performance, which was comparable to that of an experienced MSK radiologist. Therefore, PLC evaluation using the proposed DL algorithm may benefit radiologists and surgeons by enabling efficient and accurate screening of PLC injuries.
Data availability
All data generated or analyzed during this study are included in this published article (and its Supplementary Information files).
References
Rajasekaran, S., Kanna, R. M. & Shetty, A. P. Management of thoracolumbar spine trauma: An overview. Indian J. Orthop. 49, 72–82. https://doi.org/10.4103/0019-5413.143914 (2015).
Vaccaro, A. R. et al. A new classification of thoracolumbar injuries: the importance of injury morphology, the integrity of the posterior ligamentous complex, and neurologic status. Spine (Phila Pa 1976) 30, 2325–2333. https://doi.org/10.1097/01.brs.0000182986.43345.cb (2005).
Terk, M. R., Hume-Neal, M., Fraipont, M., Ahmadi, J. & Colletti, P. M. Injury of the posterior ligament complex in patients with acute spinal trauma: Evaluation by MR imaging. AJR Am. J. Roentgenol. 168, 1481–1486. https://doi.org/10.2214/ajr.168.6.9168711 (1997).
Khurana, B., Sheehan, S. E., Sodickson, A., Bono, C. M. & Harris, M. B. Traumatic thoracolumbar spine injuries: What the spine surgeon wants to know. Radiographics 33, 2031–2046. https://doi.org/10.1148/rg.337135018 (2013).
Lee, H. M. et al. Reliability of magnetic resonance imaging in detecting posterior ligament complex injury in thoracolumbar spinal fractures. Spine (Phila Pa 1976) 25, 2079–2084. https://doi.org/10.1097/00007632-200008150-00012 (2000).
Kumar, Y. & Hayashi, D. Role of magnetic resonance imaging in acute spinal trauma: A pictorial review. BMC Musculoskelet. Disord. 17, 310. https://doi.org/10.1186/s12891-016-1169-6 (2016).
Park, H. J. et al. Modified thoracolumbar injury classification and severity score (TLICS) and its clinical usefulness. Acta Radiol. 57, 74–81. https://doi.org/10.1177/0284185115580487 (2016).
Vaccaro, A. R. et al. Injury of the posterior ligamentous complex of the thoracolumbar spine: A prospective evaluation of the diagnostic accuracy of magnetic resonance imaging. Spine (Phila Pa 1976) 34, E841-847. https://doi.org/10.1097/BRS.0b013e3181bd11be (2009).
Rihn, J. A. et al. Using magnetic resonance imaging to accurately assess injury to the posterior ligamentous complex of the spine: A prospective comparison of the surgeon and radiologist. J. Neurosurg. Spine 12, 391–396. https://doi.org/10.3171/2009.10.SPINE08742 (2010).
Li, J., Xiang, Z., Zhou, J. & Zhang, M. Three-dimensional reconstruction of a CT image under deep learning algorithm to evaluate the application of percutaneous kyphoplasty in osteoporotic thoracolumbar compression fractures. Contrast Media Mol. Imaging 2022, 9107021. https://doi.org/10.1155/2022/9107021 (2022).
Kuo, R. Y. L. et al. Artificial intelligence in fracture detection: A systematic review and meta-analysis. Radiology 304, 50–62. https://doi.org/10.1148/radiol.211785 (2022).
Kong, S. H. et al. Development of a spine X-ray-based fracture prediction model using a deep learning algorithm. Endocrinol. Metab. (Seoul) https://doi.org/10.3803/EnM.2022.1461 (2022).
Kim, K. C., Cho, H. C., Jang, T. J., Choi, J. M. & Seo, J. K. Automatic detection and segmentation of lumbar vertebrae from X-ray images for compression fracture evaluation. Comput. Methods Programs Biomed. 200, 105833. https://doi.org/10.1016/j.cmpb.2020.105833 (2021).
Yeh, Y. C. et al. Deep learning approach for automatic landmark detection and alignment analysis in whole-spine lateral radiographs. Sci. Rep. 11, 7618. https://doi.org/10.1038/s41598-021-87141-x (2021).
Li, Y. C. et al. Can a deep-learning model for the automated detection of vertebral fractures approach the performance level of human subspecialists?. Clin. Orthop. Relat. Res. https://doi.org/10.1097/CORR.0000000000001685 (2021).
Li, Y. et al. Differential diagnosis of benign and malignant vertebral fracture on CT using deep learning. Eur Radiol https://doi.org/10.1007/s00330-021-08014-5 (2021).
Cina, A. et al. 2-step deep learning model for landmarks localization in spine radiographs. Sci. Rep. 11, 9482. https://doi.org/10.1038/s41598-021-89102-w (2021).
Gonzalez, R. C. & Woods, R. E. Digital Image Processing. (Pearson, 2018).
Zuiderveld, K. J. in Graphics gems.
Oktay, O. et al. Attention u-net: Learning where to look for the pancreas. arXiv:1804.03999 (2018).
Szegedy, C., Ioffe, S., Vanhoucke, V. & Alemi, A. A. in Thirty-first AAAI conference on artificial intelligence.
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J. & Wojna, Z. in Proceedings of the IEEE conference on computer vision and pattern recognition. 2818–2826.
Chollet, F. in 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). 1800–1807.
Howard, A. G. et al. Mobilenets: Efficient convolutional neural networks for mobile vision applications. arXiv:1704.04861 (2017).
Tan, M. & Le, Q. in International conference on machine learning. 6105–6114 (PMLR).
Selvaraju, R. R. et al. in Proceedings of the IEEE International Conference on Computer Vision. 618–626.
Wang, S., Jiang, Z., Yang, H., Li, X. & Yang, Z. Automatic segmentation of lumbar spine MRI images based on improved attention U-net. Comput Intell. Neurosci. 2022, 4259471. https://doi.org/10.1155/2022/4259471 (2022).
Szegedy, C. et al. Going deeper with convolutions. arXiv:1409.4842 (2015).
He, K., Zhang, X., Ren, S. & Sun, J. in Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition. 770–778.
Pawar, K., Chen, Z., Shah, N. J. & Egan, G. F. Suppressing motion artefacts in MRI using an Inception-ResNet network with motion simulation augmentation. NMR Biomed 35, e4225. https://doi.org/10.1002/nbm.4225 (2022).
Siciarz, P. & McCurdy, B. U-net architecture with embedded Inception-ResNet-v2 image encoding modules for automatic segmentation of organs-at-risk in head and neck cancer radiation therapy based on computed tomography scans. Phys. Med. Biol. https://doi.org/10.1088/1361-6560/ac530e (2022).
Vaccaro, A. R. et al. Assessment of injury to the posterior ligamentous complex in thoracolumbar spine trauma. Spine J. 6, 524–528. https://doi.org/10.1016/j.spinee.2006.01.017 (2006).
Koh, Y. D., Kim, D. J. & Koh, Y. W. Reliability and validity of Thoracolumbar Injury Classification and Severity Score (TLICS). Asian Spine J. 4, 109–117. https://doi.org/10.4184/asj.2010.4.2.109 (2010).
Lee, G. Y. et al. MRI inter-reader and intra-reader reliabilities for assessing injury morphology and posterior ligamentous complex integrity of the spine according to the thoracolumbar injury classification system and severity score. Korean J. Radiol. 16, 889–898. https://doi.org/10.3348/kjr.2015.16.4.889 (2015).
Jones, R. M. et al. Assessment of a deep-learning system for fracture detection in musculoskeletal radiographs. NPJ Digit. Med. 3, 144. https://doi.org/10.1038/s41746-020-00352-w (2020).
Tomita, N., Cheung, Y. Y. & Hassanpour, S. Deep neural networks for automatic detection of osteoporotic vertebral fractures on CT scans. Comput. Biol. Med. 98, 8–15. https://doi.org/10.1016/j.compbiomed.2018.05.011 (2018).
Yeh, L. R. et al. A deep learning-based method for the diagnosis of vertebral fractures on spine MRI: Retrospective training and validation of ResNet. Eur Spine J. 31, 2022–2030. https://doi.org/10.1007/s00586-022-07121-1 (2022).
Acknowledgements
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2021R1G1A1094067).
Author information
Authors and Affiliations
Contributions
Conceptualization: E.K.K; Data curation: E.K.K, S.W.J; Investigation: E.K.K, S.W.J, Y.S.Y, K.Y.L; Methodology: E.K.K, S.W.J, J.H.L, H.K, S.Y.L; Resources: E.K.K, Y.S.Y, J.G.C, J.H.L, H.K, S.Y.L; Supervision: E.K.K, S.W.J, I.C; Validation: S.W.J, I.C, Y.S.Y, J.G.C, K.Y.L; Visualization: S.W.J, J.H.L, H.K, S.Y.L; Writing-original draft/review & editing: E.K.K, S.W.J.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Jo, S.W., Khil, E.K., Lee, K.Y. et al. Deep learning system for automated detection of posterior ligamentous complex injury in patients with thoracolumbar fracture on MRI. Sci Rep 13, 19017 (2023). https://doi.org/10.1038/s41598-023-46208-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-46208-7
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.