Abstract
Long bone fractures are a concern in long-duration exploration missions (LDEM) where crew autonomy will exceed the current Low Earth Orbit paradigm. Current crew selection assumptions require extensive complete training and competency testing prior to flight for off-nominal situations. Analogue astronauts (n = 6) can be quickly trained to address a single fracture pattern and then competently perform the repair procedure. An easy-to-use external fixation (EZExFix) was employed to repair artificial tibial shaft fractures during an inhabited mission at the Mars Desert Research Station (Utah, USA). Bone repair safety zones were respected (23/24), participants achieved 79.2% repair success, and median completion time was 50.04 min. Just-in-time training in-mission was sufficient to become autonomous without pre-mission medical/surgical/mechanical education, regardless of learning conditions (p > 0.05). Similar techniques could be used in LDEM to increase astronauts’ autonomy in traumatic injury treatment and lower skill competency requirements used in crew selection.
Similar content being viewed by others
Introduction
Future crewed missions beyond low earth orbit will compel researchers and scientists to question our understanding of the health, safety and autonomy of astronauts and to devise new strategies to guarantee their safety and survival chances1,2. Nowadays, crew selection for future missions relies on the Knowledge – Skill – Ability – Other traits (KSAOs) concept3. However, maximizing the effectiveness and cost-efficiency of astronaut education requires considering the time and ease of acquiring valuable skills. This study focuses on this new and additional insight applied on long bone fracture repair capability, which is merely an example to illustrate the overall approach to any capability.
The decrease in bone mineral density (BMD)4,5,6,7,8,9,11 is a major health concern for astronauts 4,5,6,7,8,9 encountered during long-duration exploration missions (LDEM) (defined by NASA as longer than 30 days10), occurring as early as the first month of microgravity 4,7,8. Astronauts’ BMD continues to decline by 1 to 2.2% per month 9,10, similar to the annual decrease in postmenopausal women11, rendering their bones more fragile and prone to fracturing upon return to gravity1,9,10,12,13,14. After a long duration interplanetary journey in weightlessness, landing on Mars, with a gravity field a third of that on Earth, would increase the risk of fractures when the astronauts with reduced BMD carry out demanding tasks on the surface of the red planet9. A Bone Fracture Risk Model (BFxRM) was developed by NASA to compute the fracture risk based on patient characteristics (e.g. age, sex, initial BMD), duration of space missions and cumulative microgravity exposures, as well as shocks and protective load absorption of specific activities and/or equipment15. This study showed that the risk of fractures on Mars was higher due to weakened bone integrity, with the wrist in the first position15. Lower extremity stress fracture are also much more frequent than hip/proximal femur fracture in partial gravity environments16. Physical exercise and pharmacological prevention, advised in order to limit the BMD loss, may not counteract it completely4,6,12,13. Despite their exercise programs, 92% of astronauts on board of Mir and/or ISS space stations suffered a minimum of 5% BMD loss in at least one skeletal area12, and 40% experienced 10% or more BMD loss throughout the body12.
The occurrence of a long bone fracture in space, coupled with the lack of medical orthopaedic expertise, could endanger the health and/or life of the injured astronaut and compromise the whole mission. An untreated fracture presents risks of haemorrhage, infection, fat embolism and fat embolism syndrome, all of which can sometimes be life-threatening, and later, risks of non-consolidation, malunion and, ultimately, major loss of autonomy17,18,19.
Given a journey of six to eight months to return from Mars to Earth, an expedited abort return is impossible20. Although telesurgery has improved, transmission delays (e.g. 6 to 44 min between Earth and Mars, depending on relative planetary positions) remains problematic for performing remote surgery by an Earth surgeon or even for tele-mentoring (surgery performed by astronaut with the guidance of an Earth surgeon)1,2,9,20,21. Remote astronaut crews will require medical autonomy to diagnose and treat injuries20.
To our knowledge, little is known about bone remodelling and fracture repair in a space environment, the optimal treatment for healing long bone fractures on Mars (cast, internal plating, intramedullary nailing…) and the impact of surgery in weightlessness9,22. BMD loss is known to persist after returning to Earth, and the reversal of these changes can be slow suggesting that the time needed for complete bone regeneration can be longer than the mission itself5,8. The consolidation rate of a bone fracture seems to be lower in microgravity than on Earth with a smaller and weaker callus1,23. Achieving sufficient stability through orthopaedic treatment is crucial for promoting fracture consolidation along the correct axis, thereby avoiding potential complications like non-union or infection. This can be possible with all classical orthopaedic procedures 24,25, nevertheless, space is more demanding. Amongst others, the external fixator stands as the treatment of choice for space applications, capable of managing all types of fractures in a hostile environment characterized by limited resources and the absence of healthcare facilities to address complications.
Regarding generalised trauma, tibial shaft fractures are among the commonest open or closed long bones fractures on Earth24,26,27 and are conventionally treated using various orthopaedic surgical procedures, including the external fixator. Our study model focuses on the lower limb. A metallic device, consisting of pins inserted into the bone, connected to rods outside the leg, offers strength and support for the healing bone and surroundings. We propose the application of an easy-to-use external fixator (EZExFix)28,29 procedure under realistic operational conditions on Mars, and have assessed it during a two weeks simulation mission at the Mars Desert Research Station (MDRS, Utah). The goal was to offer astronauts the opportunity to learn, during the mission, in an accelerated manner the procedure to set up the EZExFix, without relying on Earth-based support and without requiring extensive prior surgical training. We then evaluated effectiveness and autonomy of each astronaut during the surgery, as well as safety of the injured astronaut. Broadening the scope of the study, the need for a medical and/or mechanical/engineering background, and the reaction to the stressful conditions imposed by the mission were evaluated. This approach could improve the cost-effectiveness of meeting KSAOs requirements.
Material and methods
Study design
Six analogue astronauts from crew 227 of the Tharsis mission (2022) at the MDRS gave written informed consent to participate in this research into bone fracture surgery. The methods were performed in accordance with relevant guidelines and regulations and approved by the hospital-faculty ethics committee of the Cliniques Universitaires Saint-Luc, Belgium (N°B403201523492).
Knowledge group
Astronauts were divided into 3 groups according to their educational background. The first group called “Anat” was somewhat skilled in human anatomy (studies in the medical or biomedical field but not in surgery). The second group called “Meca”, had knowledge of mechanics, stability, forces movements and constraints (civil engineering degree). The third group, “Others”, had no prior knowledge of either anatomy or mechanics. In Belgium, an experienced orthopaedic and trauma surgeon performed the same surgery three times to provide a reference to serve as the “surgical control”. He was experienced with the classical Hoffmann® external fixators30,31,32 but not the EZExFix. He therefore received the same pre-surgery theoretical information as the astronauts would receive before performing the surgery.
Experimentations
On day one of the mission, the three groups first attended a quick one-hour theoretical course on indications, anatomical landmarks and steps to attach the EZExFix followed by a practical demonstration.
Subsequently, each astronaut had to perform all eight tasks one after the other, sometimes as the operator placing the EZExFix on the broken leg (referred to as “Anat 1” or “Anat 2” depending on the person in the “Anat” group), sometimes as the assistant, helping to maintain the fracture reduction. Two surgeries were performed simultaneously by two astronauts during which they had to set up the EZExFix to repair an artificial broken leg, in the most efficient and quickest way, similar to a time trial. Twelve different combinations, or blocks, were therefore needed to crossmatch all operators (Fig. 1). Each astronaut performed the surgery four times as the operator and four times as the assistant leading to a total of 24 surgeries for all six astronauts. The different groups can also be compared in terms of skills to assess the need for prior basic skills in anatomy or mechanics. The Fig. 1 illustrates how the study design can integrate as well as the background knowledge (name of the group), the confrontation with every different operator and three different progressive learning conditions (different colours).
Learning conditions
Given a fracture occurring in space could induce stress in the crew, different conditions were applied to detect possible differences in performance. Carrying out each surgery as a competitive timed trial highlighted the importance of time and potentially induced a stress on the two operators competing. The stress level was also changed during the mission by scheduling the surgeries under three different conditions (Fig. 1). Standard conditions (blue) implied that all equipment was already prepared laid out on a table. All astronauts had to carry on at least one surgery under standard conditions before performing it under stressful conditions. Stressful conditions were obtained by executing the surgery either during an extravehicular activity (EVA) wearing space suits (green) or at an unexpected moment, such as during the night or at mealtimes, with nothing prepared (yellow). For the sake of homogeneity, the Fig. 1 allowed to organize the time trials so that each astronaut can perform the surgeries against each member of the other two groups and so that they can perform them twice under standard conditions and two times under stress conditions (EVA and unexpected moment).
Operations scheduling
In summary, all operational constraints included four surgeries for each astronaut, all possible combinations of operators, two standard conditions and one of both stressful conditions for each astronaut, with at least one trial in standard conditions before any stressful condition. All the trials have to be completed within the two weeks of the mission.
The latter encompassed eight scientific projects alongside the EZExFix project, posing the challenge of coordinating schedules to accommodate operational restrictions and shared constraints. This complex combinatorial issue was addressed using an AI system, Romie33. This system not only initially devised an optimal mission schedule but also continually adjusted and improved the scheduling of remaining simulation days based on real-time outcomes, all aimed at enhancing mission success probabilities.
Fractured leg model
The bone model used to reproduce a fractured leg was that of a left tibia with cortical hard density and low cancellous bone structure, a pre-drilled intramedullary canal and a distal opening (LSH1385, Synbone SDN BHD, Malaysia). A simple oblique fracture line was created in the middle of the tibial diaphysis by using a laser and diamond bandsaw so as to always reproduce the same AO/OTA 42A2 closed fracture type following AO classification (Fig. 2). Soft tissues made from foam rubber sheet (22,320, Komprex®, Lohmann & Rauscher, Germany) were fixed around the bone to produce the shape of the leg and were covered by a sock to mimic the skin. The distal opening was used to attach a prosthetic foot in order to provide an indication of the axis in the event of further realignment surgeries. Each surgery required a new leg model.
External fixator
The EZExFix concept considers both the mechanical stability needed to treat a long bone fracture and the ease of execution. A new unilateral biplanar EZExFix was developed in collaboration with orthopaedic surgeons from the Cliniques Universitaires Saint-Luc (Brussels) and engineers from ECAM (High Industrial Institute, Brussels). This new technology’s core focus was to be a low-cost, fast and easy-to-use fixator to extend the use of this treatment to hostile environments28,34,35,36. Figure 3 illustrates both the parts needed to build the EZExFix and the final assembly. This device can be used to treat all types of tibial shaft fractures from the simplest to more complex and is also suitable for treatment of significant soft tissue lesions. Mechanical properties were previously validated and are similar to the Hoffmann® 3 fixator (Stryker Trauma AG, Selzach, Switzerland)29.
A Practical Quick Guide containing the key steps needed to place the EZExFix was written to help astronauts carry out their tasks (Suppl. Figure 1). Two EZExFix were created to allow face to face surgeries. Soft tissues can then be removed from the bone while keeping in place the EZExFix, which can be disassembled after data harvesting and reused for subsequent surgeries.
Analysis parameters
All parameters were examined during each experiment and for each operator. They were noted on a scorecard (Suppl. Figure 2) by a neutral examiner, someone not involved in performing surgeries. This neutral examiner remained always the same person for all tests to ensure comparative results. The scorecard facilitated parameters validation and the identification of potential mistakes or shortcomings. A video of each timed trial was simultaneously recorded for more accurate observation when required.
Safety
Patient safety is paramount and astronaut operators must not damage blood vessels, nerves, or tendons of their crewmates. Safe zones, described for the classical external fixation technique37,38 were assessed with the scorecard including five analysis criteria (Suppl. Figure 2). These safe zones are the tibial crest and the anteromedial side of the tibia, as well as the pins position with respect to joints and fracture lines. Range of movement has to be preserved; this was done by not directly inserting pins into the joint whilst also avoiding any areas that are required to move. For this reason, pins could only be inserted in the bone diaphysis. The depth of pins was also evaluated because an over-screwing by 5 mm can damage structures behind the second cortex, such as blood vessels or nerves. Each safe zone was registered as correct or not, and the sum of safe zones respected for each operation was calculated.
Procedure steps
To devise an efficient set up, steps had to be performed in a specific order (Suppl. Figure 1). Four main steps were determined, and sub-criteria for each step were established in order to determine the failure or success of each step. Since the EZExFix is limited to certain degrees of freedom, the triangulation and the frame had to be built in the first step. Then, the correct positioning of the EZExFix on the broken leg was essential in order to check the pins’ orientations, the respect of safe zones and the absence of compression point on the skin. The width of the incision in the skin (≤ 2cm), and the order in which pins were inserted were evaluated in the third step and noted on the scorecard by the neutral examiner. The total number of pins and the stability of fracture reduction were assessed in the fourth step. Skin compression and stability were both defined as main criteria directly influencing patient comorbidities and outcomes. These criteria were considered as a condition sine qua non to ensure a healthy evolution of the broken leg. Each step was defined as a success or a failure, and the sum of step outcomes was calculated for each surgery.
Time
The total time taken by each operator to complete the task was taken by the neutral examiner, as well as intermediate times for each step, expressed in minutes. The surgeries started upon instruction from the neutral examiner.
Statistical analysis
Quantitative variables were analysed in terms of central tendency (mean and median) and dispersion by the range (minimum–maximum) due to the small sample size. The normality of distributions was verified using QQ plots to determine whether to proceed with parametric or nonparametric tests. Comparisons between educational background and learning conditions were evaluated by one-way ANOVA for a quantitative variable (time). The homogeneity of variances was examined by Levene’s test. The same comparisons were evaluated by a Poisson regression for discrete variables (safe zones and steps) in order to detect a main effect and/or an interaction between both factors. The absence of overdispersion was verified by a Chi-squared test. In order to compare the different durations of each step within the astronaut group, a one-way ANOVA for repeated measures was performed. The sphericity of the variance–covariance matrix was evaluated by Mauchly’s test. The normality of residuals was verified by QQ plots for both ANOVA tests. All generalized linear models integrated multiple comparisons if justified, adjusted with a Bonferroni correction. The time comparison of each step between astronauts and the surgical control was performed with non-parametric two-tailed Mann–Whitney tests because of the small number of samples. The level of significance was always set to 0.05 in order to reject the null hypothesis. All statistics were performed using SPSS software (V.27, IBM SPSS, Inc., Chicago, IL, USA).
Results
Safety: safe zone respect
Across the 5 defined safe zones, on average four were respected systematically by each operator (median 4.0; range 2–5) (Table 1).
Pins were never inserted in the articular joints (0/24) and almost never in the fracture line (2/24), outside of the tibial crest (2/24) or outside the anteromedial side of the tibia (1/24) (Fig. 4).
Pin protrusion was the criterion failing most frequently (19/24 regardless of progress because at least 1 pin protruded more than 5 mm during 5/6 operations on the first as well as on the fourth trial). The mean number of protruding pins was 1.87 (median 1.0; range 0–8). From the three trials, the surgical control made only one pin protrusion on the first trial whilst respecting all other criteria. The different educational backgrounds of the astronauts, as well as the stress conditions, did not affect compliance with safe zones (Table 2-a).
Procedure steps
From the four scorecard steps, the astronauts satisfied on average 3.5 (median 4.0; range 1–4) (Table 1), whilst the surgical control always satisfied all four steps. Among all operations, 62.5% of astronauts performed all steps correctly (Fig. 5-a). The frame assembly was always made properly during the first step (24/24) (Fig. 5-b). Pins were placed correctly, such that the skin was not compressed, in 20/24 operations. The step called “proximal pins” in the Practical Quick Guide was successful in 19/24 operations but failed five times due to too wide a skin incision (> 2 cm). Respecting the order of pin insertion failed only once, but on three occasions fewer than eight pins were actually inserted. The “distal pins” criterion was not met three times (3/24), from which the pins count failed twice to ensure fracture stability. When only main criteria are considered, the success rate reached 79.2% (Fig. 5-c).
The different educational backgrounds amongst the astronauts did not affect their success at performing the steps because they all achieved a mean of 3.5 correctly performed steps (Table 1). The increasing stress did not alter the sequence for astronauts (Table 2-b).
Time
Descriptive analyses (Table 1) showed that an astronaut took on average 52.19 min (median 50.04; range 33.9–81.3) to perform the complete task while the surgical control took only 41.30 min (median 38.05; range 36.6–49.3). The time analyses between different steps within the astronaut population highlighted some statistical differences. Figure 6-a shows a progressive increase in the median time with increasing step number. The one-way ANOVA (Table 3) demonstrated a significant difference between step times, and pairwise comparisons highlighted that step four was significantly longer than step 1 (p = 0.000008) and step two (p = 0.018), and also that step three was longer than step one (p = 0.021).
Figure 6-b, a stacked bar graph comparing both groups (astronauts and surgical control), illustrated that the most important difference in time was in the second step. Even when the surgical time is visualized by its absolute or relative values, the second step was always longer for astronauts than for the surgical control (non-parallel dotted lines). However, this was not statistically confirmed by the Mann–Whitney test (p = 0.063) (Table 4). Regarding only relative averages of time, the fourth step was the longest for the surgical control.
The different educational backgrounds of the astronauts did not affect the total time (p = 0.904) nor the time for each step (p = 0.396, p = 0.961, p = 0.669, p = 0.340 from step 1 to 4 respectively) (Fig. 6-c). The same conclusion was reached for the stress condition (p = 0.237 for total time and p = 0.376, p = 0.175, p = 0.133 and p = 0.851 from step 1 to 4 respectively).
Discussion
Despite astronaut selection being very competitive, including healthy people meeting NASA’s strict Space Flight Human System Standards for Crew Health (NASA-STD-3001)8,10,39, spaceflight accelerate the body’s senescence. Prevention strategies to limit the BMD loss are unavoidable and have been explored extensively in the literature, but are also fallible7. Nonetheless, detail about fracture management in spatial missions is lacking in the literature1. This study did not address osteoporosis prevention but focused on a solution to treat a consequence of LDEM by learning quickly how to use an EZExFix to fix long bone fractures.
Safe zones
Initially, astronauts could consult the Practical Quick Guide (Suppl. Figure 1) to help them. However, from the third trial, it was no longer consulted. Safe zones were almost always respected, ensuring a safe surgery for patients. The only criterion that could generate a problem was the protrusion of pins. Pins were self-drilling and self-tapping and were thus inserted without pre-drilling, meaning astronauts were not able to feel the right depth. Actually, pre-drilling allows surgeons to feel the passage through the second bone cortex and offers the possibility of measuring the depth to which the pin should be driven, without recourse to radioscopy. This step was not integrated in this procedure in order to minimize the time and the number of surgical instruments needed but could be implemented easily. Another option could be the use of a pinless fixator40,41. Unicortical external fixators have also been developed avoiding cortex protrusions and limiting deep infection complications42.
Workflow
Concerning the steps and major sub-criteria required to achieve fracture healing, astronauts reached a success rate of nearly 80%, meaning that the EZExFix is a good device, easy to use and to learn for the purpose of repairing long bone fractures. Nevertheless, improvements in both major and minor sub-criteria are still possible. Minor criteria could be enhanced by taking precautions when drilling. In practice, the artificial leg skin, represented by a sock, is prone to wrap around the pin when drilling leading to too wide a skin incision. However, in a real operating theatre, the same mechanism can occur with soft tissues between skin and bone. This issue could be addressed simply by using a protective sleeve to separate the pin’s thread from soft tissues.
Manipulation time
Analogue astronauts took longer (mean 52.19 min, median 50.04; range 33.9–81.3) than the surgical control to place an EZExFix but followed the mean operating time in the literature. Different authors described a range of mean times to place an external fixator on a femur or tibia of between 35 and 74.6 minutes43,44,45. However, when analysing separate steps, astronauts took significantly more time for steps three and four than first two steps. The step that showed the most difference in time between the astronauts and the surgical control was the second step. Astronauts spent more time performing the second step to place correctly the EZExFix and to avoid skin compression, which is a main sub-criterion influencing good evolution. The longest step for both astronauts and surgical control was the fourth step, including fracture reduction and stabilization which is the second main sub-criterion46. Thus, astronauts automatically became aware of the paramount relevance of these two main criteria to rescue their patients, whereas surgeons only need to focus on the fourth step, probably because the second one is more easily acquired by their own experience. One limitation in interpreting these results is that the variance of the surgical group was reduced to its within operator variance, whereas the variance of the astronaut group was made up of within and between operator variances. For this reason, comparisons between the astronauts and the surgical group give an idea of what can be expected or what the astronauts should achieve but should be interpreted with caution.
Training time
The literature already made the link between the selection and training of surgeons and astronauts47, both needing a high level of prerequisites in terms of KSAOs. The need for a medical expertise seems to increase with the mission duration and the size of the crew20. To ensure the safety and maintenance of the crew without a physician on board, selected crew-members require medical training to manage pathological situations20, such as bone fractures or emergencies. The time and the ease of learning a useful technique is essential to maximize the efficacy and the cost-effectiveness of an astronaut education. This study showed that the training accomplished within two weeks while doing other scientific activities was enough to make an astronaut autonomous in tibial shaft oblique fracture treatment with the EZExFix device, despite an increase in stress conditions. The educational background did not influence outcomes, suggesting that only the quick theoretical course at the beginning was sufficient to understand and adequately perform the task irrespective of the astronaut’s basic knowledge. This observation means that the KSAOs initial requirements could be revised or adapted for astronaut’s selection because all astronauts could reach some skills and abilities in a very short period and without previous extensive knowledge.
Limitations and further work
One limit of this study was the small number of subjects. Since the space analogue habitat is not compatible with many subjects, one way to address this would be to repeat the experiments in subsequent missions to supports these results. Other types of fractures could also be considered in forthcoming missions, such as wrist fractures.
Sterility, not evaluated in this study, could be considered in future studies. Despite the ease of the EZExFix procedure, sterility is a recommended parameter because it remains an aseptic surgical procedure. However, the EFORT (European federation of national associations of orthopaedics and traumatology) open reviews allowed the use of external fixator in the emergency department for life-threatening patients with pelvic, tibial, femoral or humeral instability37. Subsequent studies should collectively incorporate additional parameters (e.g., diagnosis, sterility as well as the set up of a suitable surgical environment), as the need to react to an emergent situation might impact the pace at which the participants perform the required tasks.
One disadvantage of the EZExFix is the difficulty to maintain a pressurized suit. Further research is required to evaluate the possibility of reducing the size of the EZExFix until it can fit inside the suit without loosening its mechanical properties, or of adapting the suit with a larger leg or to compartmentalize pressurized zones. Currently, this device is not suitable in EVA and repatriation into the pressurized habitat would be mandatory.
The EZExFix is a surgical technique that typically encourages secondary healing with callous formation. Nonetheless, since the fracture callus creation can be smaller and weaker in low gravity conditions1,23, astronauts should consider realigning the fracture and applying compression before securing the distal part of the construct in order to maximize the potential for direct bone healing. As the comprehension of fracture repair mechanisms in low gravity environment remains uncertain9,22,23, factors influencing direct or indirect bone healing required further investigation.
A major concern is taking care of soft tissue (especially in open fractures) and wound healing, which could be impaired in space conditions by increasing cell apoptosis, inflammation and decreasing matrix formation48,49. While allowing preservation of fracture hematoma, external fixation is also less invasive than other surgical fixation methods thereby decreasing bleeding, infection risk and comorbidities. It is also possible that a non-surgeon astronaut could use it without extensive surgical training1,50. This technique could also be performed under local or locoregional anaesthesia, which are preferable in space due to their safety, fast recovery, ease of use, antagonist availability and smaller equipment needed while avoiding endotracheal intubation and hazardous manipulation of volatile gaseous anesthetics9,50. The onboard supplies have to be scheduled strategically in advance in order to minimize the mass, the size and the amount of equipment and maximize its function and efficiency2,21. The storage space required for an EZExFix would not exceed 35 × 20 × 10 cm and could be stored readily. A correctly executed EZExFix procedure could certainly allow weight-bearing on Mars because mechanical tests on Earth were satisfactory29. Weight-bearing is of primary importance for the mission success, autonomy and promotes faster consolidation1 than is possible with a cast. External fixation is the only orthopaedic therapy that offers all these benefits in one device.
Conclusion
While LDEM may lead to a decrease in BMD and potentially increase the risk of fractures, the ability to autonomously manage long bone fractures is crucial for the success of such missions. In cases where a lower extremity fracture of the tibia is suspected, the accurate diagnosis should be made. Immediate on-site imaging techniques like ultrasounds can help confirm the diagnosis and determine the need for an EZExFix. Ideally, the injured astronaut should be transported to a secure location, such as the back of the pressurized rover or the main base, where local anaesthesia can be administered, and the injury site sterilized to the best possible extent before the fixation procedure is performed. Subsequently, astronauts would be able to autonomously fix a tibial shaft fracture with an EZExFix. This study is encouraging for space exploration because this device could be considered as safe, easy, quick and efficient to treat astronaut fractures, in an autonomous way, without ground assistance, without the deployment of large equipment, without the need for a medical/surgical or mechanical background, and with only a few days of training. Similar techniques could be used in LDEM to increase astronauts’ autonomy in traumatic injury treatment and lower skill competency requirements used in crew selection.
Data availability
All data analysed during the study are included in this published article. The complete original datasets generated during the current study are available from the corresponding author on reasonable request.
References
Swaffield, T. P., Neviaser, A. S. & Lehnhardt, K. Fracture risk in spaceflight and potential treatment options. Aerosp. Med. Hum. Perform. 89, 1060–1067 (2018).
Thirsk, R. B. Health care for deep space explorers. Ann. ICRP 49, 182–184 (2020).
Landon, L. B., Rokholt, C., Slack, K. J. & Pecena, Y. Selecting astronauts for long-duration exploration missions: Considerations for team performance and functioning. REACH 5, 33–56 (2017).
Lau, P., Vico, L. & Rittweger, J. Dissociation of bone resorption and formation in spaceflight and simulated microgravity: Potential role of myokines and osteokines?. Biomedicines 10, 342 (2022).
LeBlanc, A., Shackelford, L. & Schneider, V. Future human bone research in space. Bone 22, 113S-116S (1998).
Cavanagh, P. R., Licata, A. A. & Rice, A. J. Exercise and pharmacological countermeasures for bone loss during long-duration space flight. Gravit. Space Biol. Bull. 18, 39–58 (2005).
Sibonga, J. D., Spector, E. R., Johnston, S. L. & Tarver, W. J. Evaluating bone loss in ISS astronauts. Aerosp. Med. Hum. Perform. 86, 38–44 (2015).
Vico, L. et al. Effects of long-term microgravity exposure on cancellous and cortical weight-bearing bones of cosmonauts. Lancet 355, 1607–1611 (2000).
Ball, J. R. & Evans, C. H. Jr. Safe Passage: Astronaut Care for Exploration Missions (National Academies Press, 2001).
Orwoll, E. S. et al. Skeletal health in long-duration astronauts: Nature, assessment, and management recommendations from the NASA bone summit: Skeletal health in long-duration astronauts. J. Bone Miner. Res. 28, 1243–1255 (2013).
Ahlborg, H. G., Johnell, O., Turner, C. H., Rannevik, G. & Karlsson, M. K. Bone loss and bone size after menopause. N. Engl. J. Med. 349, 327–334 (2003).
LeBlanc, A. D., Spector, E. R., Evans, H. J. & Sibonga, J. D. Skeletal responses to space flight and the bed rest analog: A review. J. Musculoskelet. Neuronal Interact 7, 33–47 (2007).
Grimm, D. et al. The impact of microgravity on bone in humans. Bone 87, 44–56 (2016).
Sibonga, J. Risk of bone fracture due to spaceflight-induced changes to bone. Human Health Countermeasures (HHC) (2022).
Nelson, E. S., Lewandowski, B., Licata, A. & Myers, J. G. Development and validation of a predictive bone fracture risk model for astronauts. Ann. Biomed. Eng. 37, 2337–2359 (2009).
Antonsen, E. et al. Comparison of health and performance risk for accelerated mars mission scenarios (2021).
Rothberg, D. L. & Makarewich, C. A. Fat embolism and fat embolism syndrome. J. Am. Acad. Orthop. Surg. 27, e346–e355 (2019).
O’Neill, D. C., Dekeyser, G. J., Mortensen, A. J. & Makarewich, C. A. Adolescent fat embolism syndrome after closed tibial shaft fracture: Treatment with emergent external fixation. Case Rep. Orthop. 2021, 1–6 (2021).
Manon, J. et al. Can infection be predicted after intramedullary nailing of tibial shaft fractures?. Acta Orthop. Belg. 86, 313–319 (2020).
Saluja, I. S. et al. Survey of astronaut opinions on medical crewmembers for a mission to Mars. Acta Astronautica 63, 586–593 (2008).
Kirkpatrick, A. W., Campbell, M. R., Novinkov, O. L., Goncharov, I. B. & Kovachevich, I. V. Blunt trauma and operative care in microgravity: a review of microgravity physiology and surgical investigations with implications for critical care and operative treatment in space. J. Am. Coll. Surg. 184, 441–453 (1997).
Dadwal, U. C. et al. The effects of spaceflight and fracture healing on distant skeletal sites. Sci. Rep. 9, 11419 (2019).
Gadomski, B. C. et al. Partial gravity unloading inhibits bone healing responses in a large animal model. J. Biomech. 47, 2836–2842 (2014).
Manon, J. et al. Predictors of mechanical complications after intramedullary nailing of tibial fractures. Orthop. Traumatol. Surg. Res. 105, 523–527 (2019).
Manon, J. et al. Quels sont les facteurs prédictifs d’une complication mécanique après enclouage centromédullaire d’une fracture diaphysaire du tibia?. Revue de Chirurgie Orthopédique et Traumatologique 105, 353–357 (2019).
Bergh, C., Wennergren, D., Möller, M. & Brisby, H. Fracture incidence in adults in relation to age and gender: A study of 27,169 fractures in the Swedish Fracture Register in a well-defined catchment area. PLoS ONE 15, e0244291 (2020).
Court-Brown, C. M., Rimmer, S., Prakash, U. & McQueen, M. M. The epidemiology of open long bone fractures. Injury 29, 529–534 (1998).
Kouassi, K.J.-E. et al. Locally developed external fixators as definitive treatment of open tibia diaphyseal fractures: A clinical prospective study conducted in Ivory Coast. Int. Orthop. (SICOT) 46, 79–87 (2022).
Kouassi, K.J.-E., Cartiaux, O., Fonkoué, L., Detrembleur, C. & Cornu, O. Biomechanical study of a low-cost external fixator for diaphyseal fractures of long bones. J. Orthop. Surg. Res. 15, 247 (2020).
Seligson, D. Evolution of the Hoffmann fixators. Injury 46, S3–S6 (2015).
Schwechter, E. M. & Swan, K. G. Raoul Hoffmann and his external fixator. J. Bone Jt. Surg. 89, 672–678 (2007).
Carroll, E. A. & Koman, L. A. External fixation and temporary stabilization of femoral and tibial trauma. J. Surg. Orthop. Adv. 20, 74–81 (2011).
Saint-Guillain, M. et al. Enabling astronaut self-scheduling using a robust advanced modelling and scheduling system: An assessment during a Mars analogue mission. Adv. Space Res. https://doi.org/10.1016/j.asr.2023.03.045 (2023).
Kouassi, K.J.-E. et al. La prise en charge des fractures ouvertes de jambe dans une structure hospitalière en Côte d’Ivoire pose-t-elle problème et pourquoi ?. Revue de Chirurgie Orthopédique et Traumatologique 105, 654–658 (2019).
Kouassi, K.J.-E., Manon, J., Fonkoue, L., Detrembleur, C. & Cornu, O. Treatment of open tibia fractures in Sub-Saharan African countries: A systematic review. Acta Orthop. Belg. 87, 85–92 (2021).
Kouassi, K. J. E. et al. Is the management of open leg fractures in a hospital facility in ivory coast a problem and why? In 38th Annual Meeting of the European Bone and Joint Infection Society (EBJIS) (2019).
Encinas-Ullán, C. A., Martínez-Diez, J. M. & Rodríguez-Merchán, E. C. The use of external fixation in the emergency department: Applications, common errors, complications and their treatment. EFORT Open Rev. 5, 204–214 (2020).
Nayagam, S. Safe corridors in external fixation: The lower leg (tibia, fibula, hindfoot and forefoot). Strat. Trauma Limb Reconstruct. 2, 105–110 (2007).
National Aeronautics and Space Administration (US). Space flight human system standard. Vol 1 (2007).
Thomas, S. R. Y. W., Giele, H. & Simpson, A. H. R. W. Advantages and disadvantages of pinless external fixation. Injury 31, 805–809 (2000).
Chawla, S. Technology update: Pinless external fixator. Med. J. Armed Forces India 57, 234–236 (2001).
Russo, A.-P. et al. Sequential management of tibial fractures using a temporary unicortical external fixator. SICOT-J 4, 39 (2018).
Scalea, T. M. et al. External fixation as a bridge to intramedullary nailing for patients with multiple injuries and with femur fractures: Damage control orthopedics. J. Trauma Injury Infect. Crit. Care 48, 613–623 (2000).
Bayrak, A. et al. Which external fixation method is better for the treatment of tibial shaft fractures due to gunshot injury?. Orthop. Traumatol. Surg. Res. https://doi.org/10.1016/j.otsr.2021.102948 (2021).
Haonga, B. T. et al. Early treatment of open diaphyseal tibia fracture with intramedullary nail versus external fixator in Tanzania: Cost effectiveness analysis using preliminary data from Muhimbili Orthopaedic Institute. SICOT-J 5, 20 (2019).
Manon, J. et al. An easy-to-use external fixator for all hostile environments, from space to war medicine: Is it meant for everyone’s hands?. JCM 12, 4764 (2023).
Ball, C. G., Kirkpatrick, A. W., Feliciano, D. V., Reznick, R., & McSwain, N. E. Surgeons and astronauts: so close, yet so far apart.
Riwaldt, S. et al. Role of apoptosis in wound healing and apoptosis alterations in microgravity. Front. Bioeng. Biotechnol. 9, 679650 (2021).
Marvasi, M., Monici, M., Pantalone, D. & Cavalieri, D. Exploitation of skin microbiota in wound healing: Perspectives during space missions. Front. Bioeng. Biotechnol. 10, 873384 (2022).
Kirkpatrick, A. W. et al. Severe traumatic injury during long duration spaceflight: Light years beyond ATLS. J. Trauma Manag. Outcomes 3, 4 (2009).
Acknowledgements
The authors would like to deeply thank Dr. Shannon Rupert as well as the Mars Desert Research Station committee and the Mars Society to welcome the crew in the Utah desert for the simulation and for the opportunity to execute this research in a Mars analogue environment. This work was supported by a F.S.R. Fund (« Fonds Spéciaux de Recherche », Belgium, Ref. ADi/16568.2021), a « Student Angel Fund » (Ref. 304907648 val-31.05.), both granted by M.A.R.S. UCLouvain crew 2022 and a F.N.R.S. Aspirant Fund granted by Dr. Julie Manon (« Fonds National de la Recherche Scientifique », Application ID 40004991, Belgium,). The authors also want to thank Kouamé Jean-Eric Kouassi for his PhD thesis about the creation of the new EZExFix as well as Lies Fievé and Christine de Ville de Goyet for their help to create artificial broken legs. The “Support en Méthodologie et Calcul Statistique” (SMCS, UCLouvain) also brought a precious help in statistic advice and analyses. Figure 4 was partly generated using modified template provided by Servier Medical Art (http://smart.servier.com/, accessed on 14 July 2022), licensed under a Creative Commons Attribution 3.0 imported license (https://creativecommons.org/licenses/by/3.0/).
Author information
Authors and Affiliations
Contributions
All authors agree to be accountable for the content of the work. Study design: J.M., O.Cornu and O.Cartiaux Operations scheduling: M.S.G. Mission participants : J.M., C.W., J.J., A.C., J.M., I.S.C., S.D., C.C. Experimental manipulations (fractured leg preparation, surgeries, parameters harvesting): J.M., C.W., J.J., A.C., J.M., I.S.C., S.D., O.Cornu. Manuscript writing and proofreading: J.M., O.Cornu, L.V., D.M.B., W.D., V.P., S.B., M.S.G., J.V. English correction: W.D., D.M.B. Statistical analysis: J.M., L.V., V.P. Supervision: O.Cornu, O.Cartiaux, J.V.
Corresponding author
Ethics declarations
Competing interests
Authors have no conflict of interest to declare. This research did not directly receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors but this study would not have been possible without the participation to the Mars analogue mission funded by sponsors including Louvain4space, Sabca, Aerospacelab, B12 consulting, Oscar, UDH (Urgence Depollution Hydrocarbures), UCLouvain Fipe, SBIM (Société Belge d'Informatique Médicale), Space Application, SPW (Service Public de Wallonie), Ludovic de Meuus, Fonds Jeremy, WBI (Wallonie-Bruxelles International), which the authors would like to particularly thank. These funding sources were not involved in study design, in collection, analysis and interpretation of data nor in outcomes. Trade names and trademarks are used in this report for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration or the NASA Human System Risk Board. This manuscript does not constitute an official policy or position, either expressed or implied, by the National Aeronautics and Space Administration.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Manon, J., Saint-Guillain, M., Pletser, V. et al. Adequacy of in-mission training to treat tibial shaft fractures in mars analogue testing. Sci Rep 13, 18072 (2023). https://doi.org/10.1038/s41598-023-43878-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-43878-1
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.