Abstract
The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as \(2\times 10^{-11}\) rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.
Similar content being viewed by others
Introduction
Rotation measurements are utilised for inertial navigation and earth observation exploiting the large enclosed area in fibre-optical and meter-scale ring laser gyroscopes1,2,3. Atom interferometry offers a different approach for providing absolute measurements of inertial forces with high long-term stability. Moreover, achieving the necessary areas for competitive performance with matter waves is a long-standing challenge4,5,6,7,8,9,10. We propose an atom interferometer performing multiple loops in free fall. Our setup opens the perspective for sensitivities as high as \(2\times 10^{-11}\) rad/s at 1 s, comparable to the results of the ring laser gyroscope at the geodetic observatory Wettzell1,2.
The interferometric Sagnac phase shift11 induced by a rotation \(\varvec{\Omega }\) depends linearly on the area vector \(\varvec{A}\) as described in the following equation
where E is the energy associated with the atom \(E_{\mathrm {at}}=mc^2\) or photon \(E_{\mathrm {ph}}=\hbar \omega \), m is the mass of the atom, \(\omega \) the angular frequency of the light field, and c the speed of light. Since \(E_{\mathrm {at}}\gg E_{\mathrm {ph}}\), it scales favourably for atoms, motivating early experiments12,13,14, while much larger areas were demonstrated for light2.
One avenue for rotation measurements are wave guides or traps moving atoms in loops, especially for applications requiring compact setups3. Multiple loops were created in ring traps employing quantum degenerate gases for different purposes including the investigation of superconductive flows15,16. Exploiting them for guided atomic Sagnac interferometers in optical or magnetic traps remains an experimental challenge17,18,19,20.
Another approach is based on atoms in free fall. Here, light fields driving Raman or Bragg transitions coherently split, deflect, and recombine atomic wave packets in interferometers based on three6,8 or four pulses5,7,9, implementing a single loop or two loops, respectively. Operating a three-pulse interferometer with a thermal cesium atoms in a 2 m long vacuum chamber enabled the demonstration of a noise floor of \(9\times 10^{-10}\) (rad/s)/\(\sqrt{\mathrm {Hz}}\) and a long-term instability of \(3\times 10^{-10}\) rad/s10. Aiming for more compact setups, sensors with a similar pulse configuration, but based on cold atoms with slow drift velocities showed sensitivities down to \(10^{-7}\) rad/s in 1 s close to the shot noise limit6,8, motivating an increase of the enclosed area to enhance the sensitivity. Four-pulse interferometers7,9 enabled an increase of the enclosed area to up to \(11\,\mathrm {cm}^2\), and reached sensitivities down to \(3\times 10^{-8}\) rad/s in 1 s and \(3\times 10^{-10}\) rad/s after averaging5. Dual or multi-loop interferometers have also been proposed in the context of terrestrial and space-borne infrasound gravitational wave detection designed for measuring strain rather than rotations21,22,23,24,25. Using molasses cooled atoms at microkelvin temperatures implies limits to the beam splitting efficiency26,27 and consequently to the contrast of the interferometer in the rotation sensor5,6. Additional cooling steps such as evaporative cooling provide a mitigation strategy26, thus enabling atom interferometers with high contrast28,29,30, higher-order beam splitters as a route for enhancing their sensitivity30,31,32,33,34,35,36,37,38,39,40,41,41,42,43,44, and efficient launch mechanisms28,29, which our concept builds on.
In our geometry (Fig. 1), atoms are coherently manipulated by two perpendicular light gratings (red and orange dashed lines) to form a multi-loop interferometer23. Pulsed light fields enable symmetric beam splitting of the atomic wave packets in the horizontal axis (red arrows)41,43,44,45 and relaunching in vertical direction (orange arrows)28. This approach offers a variety of advantages: (i) the free-fall time can be tuned to scale the area, (ii) the area is well defined by velocities imprinted during the coherent atom-light interactions, and (iii) the geometry utilises a single axis for beam splitting which avoids the requirement for relative alignment5,23,46. (iv) It enables multiple loops, (v) and its symmetry suppresses biases due to light shifts associated with the atom-light interaction. (vi) Moreover, our concept in principle allows incorporation of several additional measurements such as local gravity47,48 and tilt of the apparatus43 with respect to gravity.
Multi-loop geometry
Conceptually, our idea exploits multiple loops in the interferometer to effectively increase the enclosed area. When neglecting losses of contrast and atoms which may scale with the number of loops due to imperfections in the atom-light interactions, this implies a linear increase in the shot-noise limit of the sensitivity per cycle. The concept of our interferometer is detailed in Fig. 1, showing the two trajectories (blue, green) that enclose an area \(\varvec{A}\). We now describe the sequence to implement our scheme. Initially, an atomic wave packet is launched vertically. On its upward way, the wave packet interacts with the horizontal beam splitter with an effective wave number k forming two wave packets drifting apart with a momentum of \(\pm \hbar k/(2m)\) (a). After a time T, the horizontally oriented light field (red) inverts the movement of the atoms on its axis (b,d). On their way downwards due to gravity, the vertically oriented light field (orange) relaunches the atoms28 at the lowest point of the interferometer at 2T (c) reversing their momentum to move upward. The atoms pass the horizontal atom-light interaction zone again at 3T (b,d) where they are deflected towards each other and cross falling downwards at 4T (a) completing a double loop. In order to start the next loop, they are relaunched (see Fig. 2). Repetition of the procedure determines the number of loops 2n. After the last loop, the interferometer is closed by flashing a beam splitter pulse instead of an upward acceleration. Due to the specific implementation of the initial launch at position (a) and relaunch at (c), our concept only requires a single beam splitting zone (red) for the splitting and deflection operations at (a), (b) and (d)23 instead of two5,7,9 or three6,8,10.
The acquired Sagnac phase shift depends on the total time of the interferometer 4T, the effective wave vector \(\varvec{k}\), local gravity \(\varvec{g}\), number of loops 2n and reads
calculated with the methods outlined in ref.50,51,52 and similar as in refs.5,7,9,53. The relaunch velocity \(v_{\mathrm {rl}}=|\varvec{v}_{\mathrm {rl}}|=3gT\) with \(g=|\varvec{g}|\) is aligned parallel to gravity and is chosen to close the atom interferometer at its starting point (position (a) in Fig. 2). In this configuration, the effectively enclosed area is given by
It can be enlarged by a higher transverse momentum \(\hbar k=\hbar |\varvec{k}|\), e.g. by transferring more photon recoils, and by increasing the free fall time 4T of the interferometer.
Enlarging the number of loops by a factor n effectively increases the enclosed area without changing the dimensions of the geometry. We define them as the maximum wave packet separation in the horizontal axis \(S=\hbar k T/m\) and the drop distance in the vertical axis \(D=(3T/2)^2\cdot g/2\). The relaunch at 4T (or multiples of 4T for more than four loops, position (a) in Fig. 1) reuses the same light field (orange arrows) as for the first relaunch at 2T (position (c) in Fig. 1) and does thus not add complexity.
To estimate the potential sensitivity of a future experiment, we calculate the shot-noise limit based on the phase shift in Eq. (2) including the dependency on the finite cycle time. Typically, the cycle of an atom interferometer consists of the generation and preparation of the atomic ensembles during the time \(t_{\mathrm {prep}}\), the interferometer time which for our geometry reads \(n\cdot 4T\), and detecting the population of the output ports within the time \(t_{\mathrm {det}}\). This leads to a total cycle time of \(t_c=t_{\mathrm {prep}}+n\cdot 4T+t_{\mathrm {det}}\). For N detected atoms and an interferometer contrast C of the interferometer, the shot-noise limited sensitivity to rotations \(\Omega _{y}\) is given by
after an averaging time t corresponding to multiples of the cycle time \(t_{\mathrm {c}}\). Consequently, an interferometer with a small free fall time \(4T\ll t_{\mathrm {prep}}+t_{\mathrm {det}}\) benefits more from multiple loops with a scaling of \(\sim 1/n\) in Eq. (4) than other scenarios with \(4T\thickapprox t_{\mathrm {prep}}+t_{\mathrm {det}}\) that scale as \(\sim 1/\sqrt{n}\). Implementing an interferometer time \(n\cdot 4T > t_{\mathrm {prep}}\) can enable a continuous scheme by sharing \(\pi /2\) pulse between subsequent interferometers5,54. In general, our geometry offers the possibility to compensate smaller T with an appropriate n.
Table 1 (row 1, 3) reports the calculated shot-noise limited sensitivities according to Eq. (4) for two different implementations of our geometry.
Spurious phase shifts
Spurious phase shifts may degrade the sensitivity of the sensor if they are not inherently suppressed or sufficiently well controlled. The choice of symmetric beam splitting in our geometry suppresses phase noise of the beam splitting lasers, as well as the impact of spatially homogeneous AC-Stark and magnetic field shifts on the two arms of the interferometer43,44. We refer to dedicated studies for impacts of light shifts due to large momentum beam splitters34,41,55,56,57,58,59, and isolation or correlation methods to remove vibration noise47,60,61,62,63,64,65 for quantum sensors which we expect to be exploited in a future experimental realisation of our concept.
In multi-loop interferometers, the sensitivity to DC accelerations and phase errors depending on the initial position and velocity is suppressed when compared to a three-pulse or single-loop atom interferometer25,53. Still, spurious couplings remain which we now assess following the methods of refs.50,51,52. We start with a discussion of phase shifts introduced by the relaunch, and then continue with phase shifts that depend on the starting position or velocity, and the gravity gradient, that may constrain these parameters. Here, we only focus on terms we estimate to be dominating.
A non-ideal pointing of the relaunch velocity \(\varvec{v}_{\mathrm {rl}}\) may introduce spurious phase shifts in a real setup. We consider small deviations \(\alpha =|\varvec{v}_{\mathrm {rl}}\times \varvec{e}_{x}|/(|\varvec{v}_{\mathrm {rl}}||\varvec{e}_{x}|)\) and \(\beta =|\varvec{v}_{\mathrm {rl}}\times \varvec{e}_{y}|/(|\varvec{v}_{\mathrm {rl}}||\varvec{e}_{y}|)\) in a double-loop configuration. Here, \(\varvec{e}_{x}=\varvec{k}/|\varvec{k}|\) denotes the unit vector in x-direction and \(\varvec{e}_{y}=(\varvec{k}\times \varvec{g})/(|\varvec{k}||\varvec{g}|)\) denotes the unit vector in y-direction (see Fig. 1).
If the timing of the relaunch is not ideally centred around 2T, but shifted by \(\delta \tau \), coupling to non-zero \(\alpha \) leads to the phase shift23
Provided the pointing of the relaunch velocity is adjustable (e.g. with a tip-tilt mirror controlling the alignment of the light field for relaunching) \(\alpha \) and \(\delta \tau \) can be adjusted by iteratively scanning both.
In addition, tilting the relaunch vector induces phase shifts resembling those of a three-pulse or Mach-Zehnder-like interferometer50,51 by coupling to gravity gradients \(\Gamma \) and rotations \(\varvec{\Omega }\). These contributions read
with \(\Gamma _i=\varvec{e}_{i}\Gamma \varvec{e}_{i}\) for \(i=x,y,z\) and
corresponding to a spurious sensitivity to a rotation \(\Omega _{i}=\varvec{e}_i\cdot \varvec{\Omega }\) for \(i=x,y,z\).
Scanning the interferometer time 4T enables an iterative procedure to minimise spurious phase shifts by optimising the contrast46.
We now show the phase terms stemming from a coupling of starting position \(\varvec{r}_0=(x_0,y_0,z_0)\) and velocity \(\varvec{v}_0=(v_{x0},v_{y0},v_{z0})\) to rotations and gravity gradients, as well as the cross coupling between the latter. According to our estimation (see Table 1 for our choice of parameters for k, T, but using \(n=1\)), the dominating terms read:
Phase terms scaling as \(\Delta \phi _{\Gamma y} \sim k T^6 g \Gamma _y \Omega _x \Omega _z \) and \(\Delta \phi _{x0} \sim k T^4 \Gamma _x^2 x_0 \) that may constrain \(\Gamma _y\) and \(x_0\) are estimated to be negligible for our choice of parameters. Optionally, a compensation scheme implemented by small frequency detuning of the \(\pi \) pulses21,66,67,68 at \((r\cdot 4-3)T\) and \((r\cdot 4-1)T\) for \(r\in (1,2,\ldots ,n-1)\) in Fig. 2 (b, d) can reduce the impact of the gravity gradient \(\Gamma _x\) in Eq. (9). Additionally, we have to consider constraints from the beam splitting process. The velocity acceptance of the beam splitter41,43 may limit \(v_x\). Another constraint is to have the atoms within the central part of the beam splitter both at the start, limiting \(y_0\) and \(z_0\), and at the last pulse for recombination, limiting \(v_y\) and \(v_z\). The impact of a variation in g (see Eq. 2) may be reduced with a tidal model similar to the common practice in gravimeters47,61,65,69.
Table 2 reports the calculated requirements for two different implementations of our geometry.
Perspectives of the performance
Apart from the (re-)launch, our scheme with \(n=1\) resembles four-pulse interferometers5,7,9,53 in geometry and scale factor (Eqs. 2 and 3 ). Hence, we show the advantages of our method with respect to a four-pulse interferometer for two design choices. For both interferometers in Table 1 (upper four rows), we assume ideal contrast, no losses of atoms, as well as shot-noise limited sensitivities (see Eq. 4). (1) Matching the free-fall time T and sensitivity for the multi-loop and four-pulse sensor, the four-pulse interferometer requires a larger photon momentum transfer in horizontal direction. Consequently, the size \(S\cdot {D}\) of the multi-loop geometry is by a factor of 15 smaller (emphasised in bold in Table 1). (2) Aiming for similar dimensions S and D, we obtain a nearly an order of magnitude higher sensitivity for our multi-loop geometry at the cost of an increased cycle time.
Showcasing more realistic scenarios, we consider a simple model for losses of atoms and reduction of contrast in dependence on the number of loops as summarised in Table 1 (lower rows). The latter can result from inhomogeneities of the light fields34,41,55,56,57,58,59. Following our calculations and choice of parameters, we still anticipate a compact sensor with a sensitivity of \(1.2\times 10^{-7}\,(\mathrm {rad}/\mathrm {s})/\sqrt{\mathrm {Hz}}\) within a volume of 20 mm\(^3\) for the interferometer, and a highly sensitive, but larger device with \(1.7\times 10^{-11}\,(\mathrm {rad}/\mathrm {s})/\sqrt{\mathrm {Hz}}\) within a meter-sized vacuum vessel based on our method, comparable to the performance of large ring laser gyroscopes2.
Multiple experiments investigated beam splitting as well as relaunch operations as required for our scheme. They realised the transfer of large momenta with subsequent pulses or higher order transitions32,33,34,35,36,37 and their combination with Bloch oscillations30,38,39. The implementation of symmetric splitting40,41,42,43,44 was demonstrated with an effective wave number corresponding to 408 photon recoils in a twin-lattice atom interferometer41. A similar procedure enabled the relaunch of atoms28. The requirement for high efficiency implies using atomic ensembles with very low residual expansion rates26 as enabled by delta-kick collimation of evaporated atoms31,70 and Bose-Einstein condensates28,29,41,71,72. In addition, interferometers exploiting such ensembles may benefit from the suppression systematic of uncertainties73,74,75,76. Fountain geometries utilised launch techniques compatible with these ensembles28,29,31,70. Rapid generation of Bose-Einstein condensates with \(10^5\) atoms was demonstrated77,78 and realised with atom chips in 1 s79,80 which we adopted for our estimation.
Reaching the shot-noise limited sensitivity implies a restriction on tilt instability as detailed in Table 2 due to couplings in Eqs. 5, 6, and 7. It is approximately met at the modest level of \(0.1\,\mathrm {mrad/}\sqrt{\mathrm {Hz}}\) for the compact scenario and at \(7\,\mathrm {nrad/}\sqrt{\mathrm {Hz}}\) for high-sensitivity. Dedicated vibration isolation systems demonstrated a noise floor of \(1\,\mathrm {nrad/}\sqrt{\mathrm {Hz}}\) in a frequency range of 1 Hz to 100 Hz81. Alternatively, and similar as in a large ring laser gyroscope1,2, tiltmeters with a resolution of sub nrad82 may enable post correction methods. The requirements on the stability of the starting position and velocity appear to be within reach of current sources of Bose-Einstein condensates28,71,73,74,80,83.
Conclusion and discussion
We presented our concept for an atomic gyroscope capable of performing multiple loops by exploiting light pulses for beam splitting and relaunching atoms with the perspective of reaching unprecedented sensitivities for rotations. It offers unique scalability in a sensor head with a limited size. Key elements as the symmetric beam splitting41,43, relaunch28, as well preparation of the ultracold atoms70,72,79,80,84 have already been demonstrated. The tools for coherent manipulation in our scheme additionally allow for the implementation of geometries for a tiltmeter43 and a gravimeter28,47,48. We showed the perspective for compact setups, which can be scaled up to compete with large ring laser gyroscopes1,2. This might enable the detection of multiple rotational components in a single set-up by adding a second orthogonal beam splitting axis, and sensitivities as required for measuring the Lense-Thirring effect85,86,87,88.
Data availability
Datasets are available on reasonable request.
References
Gebauer, A. et al. Reconstruction of the instantaneous earth rotation vector with sub-arcsecond resolution using a large scale ring laser array. Phys. Rev. Lett. 125, 033605. https://doi.org/10.1103/PhysRevLett.125.033605 (2020).
Schreiber, K. U., Klügel, T., Wells, J.-P.R., Hurst, R. B. & Gebauer, A. How to detect the chandler and the annual wobble of the earth with a large ring laser gyroscope. Phys. Rev. Lett. 107, 173904. https://doi.org/10.1103/PhysRevLett.107.173904 (2011).
Jekeli, C. Navigation error analysis of atom interferometer inertial sensor. Navigation 52, 1–14. https://doi.org/10.1002/j.2161-4296.2005.tb01726.x (2005).
Gersemann, M., Gebbe, M., Abend, S., Schubert, C. & Rasel, E. M. Differential interferometry using a Bose–Einstein condensate. Eur. Phys. J. D 74, 203. https://doi.org/10.1140/epjd/e2020-10417-8 (2020).
Savoie, D. et al. Interleaved atom interferometry for high-sensitivity inertial measurements. Sci. Adv. 4, eaau7948. https://doi.org/10.1126/sciadv.aau7948 (2018).
Berg, P. et al. Composite-light-pulse technique for high-precision atom interferometry. Phys. Rev. Lett. 114, 063002. https://doi.org/10.1103/physrevlett.114.063002 (2015).
Stockton, J. K., Takase, K. & Kasevich, M. A. Absolute geodetic rotation measurement using atom interferometry. Phys. Rev. Lett. 107, 133001. https://doi.org/10.1103/PhysRevLett.107.133001 (2011).
Gauguet, A., Canuel, B., Lévèque, T., Chaibi, W. & Landragin, A. Characterization and limits of a cold-atom Sagnac interferometer. Phys. Rev. A 80, 063604. https://doi.org/10.1103/PhysRevA.80.063604 (2009).
Canuel, B. et al. Six-axis inertial sensor using cold-atom interferometry. Phys. Rev. Lett. 97, 010402. https://doi.org/10.1103/PhysRevLett.97.010402 (2006).
Durfee, D. S., Shaham, Y. K. & Kasevich, M. A. Long-term stability of an area-reversible atom-interferometer Sagnac gyroscope. Phys. Rev. Lett. 97, 240801. https://doi.org/10.1103/PhysRevLett.97.240801 (2006).
Sagnac, G. Léther lumineux démontré par l’effet du vent relatif d’éther dans un interféromètre en rotation uniforme. C. R. Acad. Sci. Paris 157, 708 (1913).
Gustavson, T. L., Bouyer, P. & Kasevich, M. A. Precision rotation measurements with an atom interferometer gyroscope. Phys. Rev. Lett. 78, 2046–2049. https://doi.org/10.1103/PhysRevLett.78.2046 (1997).
Riehle, F., Kisters, T., Witte, A., Helmcke, J. & Bordé, C. J. Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer. Phys. Rev. Lett. 67, 177–180. https://doi.org/10.1103/PhysRevLett.67.177 (1991).
Colella, R., Overhauser, A. W. & Werner, S. A. Observation of gravitationally induced quantum interference. Phys. Rev. Lett. 34, 1472–1474. https://doi.org/10.1103/PhysRevLett.34.1472 (1975).
Ryu, C. et al. Observation of persistent flow of a Bose–Einstein condensate in a toroidal trap. Phys. Rev. Lett.https://doi.org/10.1103/PhysRevLett.99.260401 (2007).
Gupta, S., Murch, K. W., Moore, K. L., Purdy, T. P. & Stamper-Kurn, D. M. Bose–Einstein condensation in a circular waveguide. Phys. Rev. Lett. 95, 143201. https://doi.org/10.1103/PhysRevLett.95.143201 (2005).
Moan, E. R. et al. Quantum rotation sensing with dual Sagnac interferometers in an atom-optical waveguide. Phys. Rev. Lett. 124, 120403. https://doi.org/10.1103/PhysRevLett.124.120403 (2020).
Pandey, S. et al. Hypersonic Bose–Einstein condensates in accelerator rings. Nature 570, 205–209. https://doi.org/10.1038/s41586-019-1273-5 (2019).
Stevenson, R., Hush, M. R., Bishop, T., Lesanovsky, I. & Fernholz, T. Sagnac interferometry with a single atomic clock. Phys. Rev. Lett. 115, 163001. https://doi.org/10.1103/PhysRevLett.115.163001 (2015).
Wu, S., Su, E. & Prentiss, M. Demonstration of an area-enclosing guided-atom interferometer for rotation sensing. Phys. Rev. Lett. 99, 173201. https://doi.org/10.1103/PhysRevLett.99.173201 (2007).
Canuel, B. et al. ELGAR—A European laboratory for gravitation and atom-interferometric research. Class. Quantum Gravity 37, 225017. https://doi.org/10.1088/1361-6382/aba80e (2020).
El-Neaj, Y. A. et al. AEDGE: Atomic experiment for dark matter and gravity exploration in space. Eur. Phys. J. Quantum Technol. 7, 6. https://doi.org/10.1140/epjqt/s40507-020-0080-0 (2020).
Schubert, C. et al. Scalable, symmetric atom interferometer for infrasound gravitational wave detection. Preprint at arXiv:909.01951 (2019).
Graham, P. W., Hogan, J. M., Kasevich, M. A. & Rajendran, S. Resonant mode for gravitational wave detectors based on atom interferometry. Phys. Rev. D 94, 104022. https://doi.org/10.1103/PhysRevD.94.104022 (2016).
Hogan, J. M. et al. An atomic gravitational wave interferometric sensor in low earth orbit (AGIS-LEO). Gen. Relativ. Gravit. 43, 1953. https://doi.org/10.1007/s10714-011-1182-x (2011).
Szigeti, S. S., Debs, J. E., Hope, J. J., Robins, N. P. & Close, J. D. Why momentum width matters for atom interferometry with Bragg pulses. New J. Phys. 14, 023009. https://doi.org/10.1088/1367-2630/14/2/023009 (2012).
Kasevich, M. et al. Atomic velocity selection using stimulated Raman transitions. Phys. Rev. Lett. 66, 2297–2300. https://doi.org/10.1103/PhysRevLett.66.2297 (1991).
Abend, S. et al. Atom-chip fountain gravimeter. Phys. Rev. Lett. 117, 203003. https://doi.org/10.1103/PhysRevLett.117.203003 (2016).
Dickerson, S. M., Hogan, J. M., Sugarbaker, A., Johnson, D. M. S. & Kasevich, M. A. Multiaxis inertial sensing with long-time point source atom interferometry. Phys. Rev. Lett. 111, 083001. https://doi.org/10.1103/PhysRevLett.111.083001 (2013).
McDonald, G. D. et al.\(80\hbar k\) momentum separation with Bloch oscillations in an optically guided atom interferometer. Phys. Rev. A 88, 053620. https://doi.org/10.1103/PhysRevA.88.053620 (2013).
Asenbaum, P., Overstreet, C., Kim, M., Curti, J. & Kasevich, M. A. Atom-interferometric test of the equivalence principle at the \({10}^{-12}\) level. Phys. Rev. Lett. 125, 191101. https://doi.org/10.1103/PhysRevLett.125.191101 (2020).
Rudolph, J. et al. Large momentum transfer clock atom interferometry on the 689 nm intercombination line of strontium. Phys. Rev. Lett. 124, 083604. https://doi.org/10.1103/PhysRevLett.124.083604 (2020).
Parker, R. H., Yu, C., Zhong, W., Estey, B. & Müller, H. Measurement of the fine-structure constant as a test of the standard model. Science 360, 191–195. https://doi.org/10.1126/science.aap7706 (2018).
Kovachy, T. et al. Quantum superposition at the half-metre scale. Nature 528, 530–533. https://doi.org/10.1038/nature16155 (2015).
Chiow, S.-W., Kovachy, T., Chien, H.-C. & Kasevich, M. A. 102 \(\hbar \) k large area atom interferometers. Phys. Rev. Lett. 107, 130403. https://doi.org/10.1103/PhysRevLett.107.130403 (2011).
Müller, H., Chiow, S.-W., Long, Q., Herrmann, S. & Chu, S. Atom interferometry with up to 24-photon-momentum-transfer beam splitters. Phys. Rev. Lett. 100, 180405. https://doi.org/10.1103/PhysRevLett.100.180405 (2008).
McGuirk, J. M., Snadden, M. J. & Kasevich, M. A. Large area light-pulse atom interferometry. Phys. Rev. Lett. 85, 4498. https://doi.org/10.1103/PhysRevLett.85.4498 (2000).
Müller, H., Chiow, S.-W., Herrmann, S. & Chu, S. Atom interferometers with scalable enclosed area. Phys. Rev. Lett. 102, 240403. https://doi.org/10.1103/PhysRevLett.102.240403 (2009).
Cladé, P., Guellati-Khélifa, S., Nez, F. & Biraben, F. Large momentum beam splitter using Bloch oscillations. Phys. Rev. Lett. 102, 240402. https://doi.org/10.1103/PhysRevLett.102.240402 (2009).
Pagel, Z. et al. Symmetric Bloch oscillations of matter waves. Phys. Rev. A 102, 053312. https://doi.org/10.1103/PhysRevA.102.053312 (2020).
Gebbe, M. et al. Twin-lattice atom interferometry. Nat. Commun. 12, 2544. https://doi.org/10.1038/s41467-021-22823-8 (2021).
Plotkin-Swing, B., Gochnauer, D., McAlpine, K., Jamison, A. O. & Gupta, S. Three-path atom interferometry with large momentum separation. Phys. Rev. Lett. 121, 133201. https://doi.org/10.1103/PhysRevLett.121.133201 (2018).
Ahlers, H. et al. Double Bragg interferometry. Phys. Rev. Lett. 116, 173601. https://doi.org/10.1103/PhysRevLett.116.173601 (2016).
Lévèque, T., Gauguet, A., Michaud, F., Pereira Dos Santos, F. & Landragin, A. Enhancing the area of a Raman atom interferometer using a versatile double-diffraction technique. Phys. Rev. Lett. 103, 080405. https://doi.org/10.1103/PhysRevLett.103.080405 (2009).
Giese, E., Roura, A., Tackmann, G., Rasel, E. M. & Schleich, W. P. Double Bragg diffraction: A tool for atom optics. Phys. Rev. A 88, 053608. https://doi.org/10.1103/PhysRevA.88.053608 (2013).
Tackmann, G. et al. Self alignment of a compact large-area atomic Sagnac interferometer. New J. Phys. 14, 015002. https://doi.org/10.1088/1367-2630/14/1/012002 (2012).
Peters, A., Chung, K. Y. & Chu, S. Measurement of gravitational acceleration by dropping atoms. Nature 400, 849–852. https://doi.org/10.1038/23655 (1999).
Kasevich, M. & Chu, S. Atomic interferometry using stimulated Raman transitions. Phys. Rev. Lett. 67, 181–184. https://doi.org/10.1103/PhysRevLett.67.181 (1991).
Steck, D. A. Rubidium 87 d line data, revision 2.1. http://steck.us/alkalidata (2008).
Hogan, J. M., Johnson, D. M. S. & Kasevich, M. A. Light-pulse atom interferometry. Preprint at arXiv:0806.3261 (2008).
Bongs, K., Launay, R. & Kasevich, M. A. High-order inertial phase shifts for time-domain atom interferometers. Appl. Phys. B 84, 599–602. https://doi.org/10.1007/s00340-006-2397-5 (2006).
Bordé, C. Quantum theory of atom-wave beam splitters and application to multidimensional atomic gravito-inertial sensors. Gen. Relativ. Gravit. 36, 475–502. https://doi.org/10.1023/B:GERG.0000010726.64769.6d (2004).
Dubetsky, B. & Kasevich, M. A. Atom interferometer as a selective sensor of rotation or gravity. Phys. Rev. A. 74, 023615. https://doi.org/10.1103/PhysRevA.74.023615 (2006).
Dutta, I. et al. Continuous cold-atom inertial sensor with 1 nrad/sec rotation stability. Phys. Rev. Lett. 116, 183003. https://doi.org/10.1103/PhysRevLett.116.183003 (2016).
Kim, M. et al. 40 W, 780 nm laser system with compensated dual beam splitters for atom interferometry. Opt. Lett. 45, 6555–6558. https://doi.org/10.1364/OL.404430 (2020).
Bade, S., Djadaojee, L., Andia, M., Cladé, P. & Guellati-Khelifa, S. Observation of extra photon recoil in a distorted optical field. Phys. Rev. Lett. 121, 073603. https://doi.org/10.1103/PhysRevLett.121.073603 (2018).
Zhang, X., del Aguila, R. P., Mazzoni, T., Poli, N. & Tino, G. M. Trapped-atom interferometer with ultracold Sr atoms. Phys. Rev. Ahttps://doi.org/10.1103/PhysRevA.94.043608 (2016).
Parker, R. H. et al. Controlling the multiport nature of Bragg diffraction in atom interferometry. Phys. Rev. A 94, 053618. https://doi.org/10.1103/PhysRevA.94.053618 (2016).
Estey, B., Yu, C., Müller, H., Kuan, P.-C. & Lan, S.-Y. High-resolution atom interferometers with suppressed diffraction phases. Phys. Rev. Lett. 115, 083002. https://doi.org/10.1103/PhysRevLett.115.083002 (2015).
Richardson, L. L. et al. Optomechanical resonator-enhanced atom interferometry. Commun. Phys. 3, 208. https://doi.org/10.1038/s42005-020-00473-4 (2020).
Freier, C. et al. Mobile quantum gravity sensor with unprecedented stability. J. Phys. Conf. Ser. 723, 012050. https://doi.org/10.1088/1742-6596/723/1/012050 (2016).
Lautier, J. et al. Hybridizing matter-wave and classical accelerometers. Appl. Phys. Lett. 105, 144102. https://doi.org/10.1063/1.4897358 (2014).
Hu, Z.-K. et al. Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter. Phys. Rev. A 88, 043610. https://doi.org/10.1103/PhysRevA.88.043610 (2013).
Geiger, R. et al. Detecting inertial effects with airborne matter-wave interferometry. Nat. Commun. 2, 474. https://doi.org/10.1038/ncomms1479 (2011).
Le Gouët, J. et al. Limits to the sensitivity of a low noise compact atomic gravimeter. Appl. Phys. B 92, 133–144. https://doi.org/10.1007/s00340-008-3088-1 (2008).
Sidorenkov, L. A., Gautier, R., Altorio, M., Geiger, R. & Landragin, A. Tailoring multiloop atom interferometers with adjustable momentum transfer. Phys. Rev. Lett. 125, 213201. https://doi.org/10.1103/PhysRevLett.125.213201 (2020).
Canuel, B. et al. Technologies for the ELGAR large scale atom interferometer array. Preprint at arXiv:2007.04014 (2020).
Roura, A. Circumventing Heisenberg's uncertainty principle in atom interferometry tests of the equivalence principle. Phys. Rev. Lett. 118, 160401. https://doi.org/10.1103/PhysRevLett.118.160401 (2017).
Crossley, D., Hinderer, J. & Riccardi, U. The measurement of surface gravity. Rep. Prog. Phys. 76, 046101. https://doi.org/10.1088/0034-4885/76/4/046101 (2013).
Kovachy, T. et al. Matter wave lensing to picokelvin temperatures. Phys. Rev. Lett. 114, 143004. https://doi.org/10.1103/PhysRevLett.114.143004 (2015).
Rudolph, J. Matter-wave optics with Bose–Einstein condensates in microgravity. Ph.D. thesis, Gottfried Wilhelm Leibniz Universität Hannover (2016). https://doi.org/10.15488/4702.
Müntinga, H. et al. Interferometry with Bose–Einstein condensates in microgravity. Phys. Rev. Lett. 110, 093602. https://doi.org/10.1103/PhysRevLett.110.093602 (2013).
Heine, N. et al. A transportable quantum gravimeter employing delta-kick collimated Bose–Einstein condensates. Eur. Phys. J. D 74, 174. https://doi.org/10.1140/epjd/e2020-10120-x (2020).
Karcher, R., Imanaliev, A., Merlet, S. & Pereira Dos Santos, F. Improving the accuracy of atom interferometers with ultracold sources. New J. Phys. 20, 113041. https://doi.org/10.1088/1367-2630/aaf07d (2018).
Schkolnik, V., Leykauf, B., Hauth, M., Freier, C. & Peters, A. The effect of wavefront aberrations in atom interferometry. Appl. Phys. B 120, 311. https://doi.org/10.1007/s00340-015-6138-5 (2015).
Louchet-Chauvet, A. et al. The influence of transverse motion within an atomic gravimeter. New J. Phys. 13, 065025. https://doi.org/10.1088/1367-2630/13/6/065025 (2011).
Roy, R., Green, A., Bowler, R. & Gupta, S. Rapid cooling to quantum degeneracy in dynamically shaped atom traps. Phys. Rev. A 93, 043403. https://doi.org/10.1103/PhysRevA.93.043403 (2016).
Stellmer, S., Grimm, R. & Schreck, F. Production of quantum-degenerate strontium gases. Phys. Rev. A 87, 013611. https://doi.org/10.1103/PhysRevA.87.013611 (2013).
Becker, D. et al. Space-borne Bose–Einstein condensation for precision interferometry. Nature 562, 391–395. https://doi.org/10.1038/s41586-018-0605-1 (2018).
Rudolph, J. et al. A high-flux BEC source for mobile atom interferometers. New J. Phys. 17, 065001. https://doi.org/10.1088/1367-2630/17/6/065001 (2015).
Bergmann, G. Improving the seismic isolation for the AEI 10 m prototype. Ph.D. thesis, Gottfried Wilhelm Leibniz Universität Hannover (2018). https://doi.org/10.15488/3329.
LGM 2-K High Resolution Tiltmeter (HRTM). https://www.l-gm.de.
Abend, S. Atom-chip gravimeter with Bose–Einstein condensates. Ph.D. thesis, Gottfried Wilhelm Leibniz Universität Hannover (2017). https://doi.org/10.15488/8921.
Hardman, K. S. et al. Simultaneous precision gravimetry and magnetic gradiometry with a Bose–Einstein condensate: A high precision, quantum sensor. Phys. Rev. Lett. 117, 138501. https://doi.org/10.1103/PhysRevLett.117.138501 (2016).
Everitt, C. W. F. et al. Gravity probe B: Final results of a space experiment to test general relativity. Phys. Rev. Lett. 106, 221101. https://doi.org/10.1103/PhysRevLett.106.221101 (2011).
Jentsch, C., Müller, T., Rasel, E. & Ertmer, W. Hyper: A satellite mission in fundamental physics based on high precision atom interferometry. Gen. Relativ. Gravit. 36, 2197–2221. https://doi.org/10.1023/B:GERG.0000046179.26175.fa (2004).
Schiff, L. I. Possible new experimental test of general relativity theory. Phys. Rev. Lett. 4, 215. https://doi.org/10.1103/PhysRevLett.4.215 (1960).
Lense, J. & Thirring, H. Über die Einfluß der Eigenrotation der Zentralkörper auf die Bewegung der Planeten und Monde nach der Einsteinschen Gravitationstheorie. Phys. Z 19, 156 (1918).
Acknowledgements
Funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)–Project-ID 274200144–the SFB 1227 DQ-mat within the Projects B07 and B09, and–Project-ID 434617780–SFB 1464 TerraQ within the projects A01, A02 and A03. Supported by the German Space Agency (DLR) with funds provided by the Federal Ministry of Economic Affairs and Energy (BMWi) due to an enactment of the German Bundestag under Grant No. DLR 50WM1952 and 50WM1955 (QUANTUS-V-Fallturm), 50WP1700 (BECCAL), 50RK1957 (QGYRO), and the Verein Deutscher Ingenieure (VDI) with funds provided by the Federal Ministry of Education and Research (BMBF) under Grant No. VDI 13N14838 (TAIOL). Funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategy—EXC-2123 QuantumFrontiers—Project-ID 390837967. D.S. acknowledges support by the Federal Ministry of Education and Research (BMBF) through the funding program Photonics Research Germany under contract number 13N14875. We acknowledge financial support from “Niedersächsisches Vorab” through “Förderung von Wissenschaft und Technik in Forschung und Lehre” for the initial funding of research in the new DLR-SI Institute and through the “Quantum- and Nano-Metrology (QUANOMET)” initiative within the Project QT3.
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Contributions
C.S. and E.M.R. developed the idea. P.B. and C.S. performed the calculations. All authors contributed to the discussion of the results and to the performance estimation. C.S. and E.M.R. wrote the initial draft of the manuscript. All authors contributed to, reviewed, and approved the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Schubert, C., Abend, S., Gersemann, M. et al. Multi-loop atomic Sagnac interferometry. Sci Rep 11, 16121 (2021). https://doi.org/10.1038/s41598-021-95334-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-95334-7
This article is cited by
-
Adaptive median filter salt and pepper noise suppression approach for common path coherent dispersion spectrometer
Scientific Reports (2024)
-
Toward atom interferometer gyroscope built on an atom chip
Journal of the Korean Physical Society (2023)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.