Abstract
It has long been known that neuronal axons are contractile. They actively maintain rest tension along the longitudinal direction both in vitro and in vivo. Here we show evidence that embryonic drosophila axons also actively maintain contractility/tension along the circumferential direction. We used confocal microscopy and spatial light interference microscopy to monitor axonal diameter along their length. We observed a decrease in diameter when microtubules are disrupted and an increase in diameter when actin filaments or myosin II are disrupted. Interestingly, active diameter reduction occurred consistently when axons were subjected to manipulations known to increase axial tension, suggesting that tension can be coupled in the axial and circumferential direction. This is further supported by the remarkably similar time constants for diameter reduction and rest tension increase of slackened axons. We infer that the actomyosin-driven circumferential contraction/hoop tension applies a squeezing force on the microtubule bundle of the axons. This hoop tension is balanced by the restoring force of the microtubule bundle. Therefore, axonal diameter increased when actin/myosin disrupting drugs relaxed the hoop tension and decreased when microtubule disrupting drug relaxed the restoring force. Circumferential tension thus can regulate axonal diameter and volume, as well as potentially microtubules alignment, inter-tubular spacing, and, by extension, axonal transport.
Similar content being viewed by others
Introduction
Neurons compute by integrating upstream signal inputs and propagating a single output. This signal integration and propagation requires the neuronal cell to take a specialized shape–usually in the form of many dendrites and an extended axon1. Microtubules (MT) has been thought to give axons their tubular structure2, and actin, in the form of a mesh network, was proposed to link the cytosolic MT to the axolemma3. The recent discovery of periodic subcortical actin rings and associated proteins in axons4 (and dendrites5) adds new insights to the cytoskeleton architecture. This highly regular actin network has been suggested6,7 and demonstrated8 to maintain structural integrity. How such is achieved, however, remains largely speculative.
The contractility of actin network, driven by myosin motors, is well-established to help shape cell morphology9,10. In axons, the acto-myosin machinery maintains an intrinsic axial tension in vitro 11,12 and in vivo 13,14,15. This tension can influence axonal processes such as growth16,17,18,19,20,21, synaptic plasticity13,22, and vesicle transport23 and release24. We speculate that tension could also exist in the circumferential direction, creating a hoop stress, as suggested by the ring-like actin network.
Here we use confocal microscopy and spatial light interference microscopy (SLIM)25 to infer circumferential tension by monitoring the diameter of single axons in embryonic drosophila in vivo. We report observations that suggest that this circumferential tension is coupled with the axial tension. It appears that axons regulate their diameter, and hence structure, through this coupled contractile tension.
Materials and Methods
Drosophila Culture
Transgenic embryonic drosophila (P(elav’-GAL4)[iii] P(UAS-gap::GFP, w+)[6iii]) with neuronal membranes tagged by green fluorescent protein (GFP) were used for the experiments. To harvest the embryo for dissection, flies were cultured on standard grape agar plates at room temperature (23 °C) for 18 hrs. The new embryos laid (0–18 hours old) were treated with 50% bleach for 1 minute for dechorionation, and subsequently rinsed with deionized water. We then visually inspected the embryos to select the ones with morphologies corresponding to those of stage 16. This protocol was adapted from Budnik et al.26.
Dissection and Manipulation
Selected embryos were then transferred onto a double-sided tape (Scotch; 3 M, St. Paul, MN) attached to a large glass cover slip (12-545 H; Fisher Scientific, Hampton, NH). We positioned the embryo specifically with the dorsal side, where the CNS was, touching the tape. A glass needle (World Precision Instrument, Sarasota, FL), pulled by a micro-electrode puller (Sutter Instruments, Novota, CA), of 1 μm tip size and a 20° taper was used to cut open the embryo from the posterior end to the anterior end. The fly, now free from all its cuticle, naturally adhered to the glass needle. We transferred it onto the cover slip glass surface, covered it with 500 mL of PBS (the volume is important for later drug concentration), and subsequently removed the inner organs until the body wall could be laid unrolled with the CNS exposed for further manipulations.
Intersegmental nerves, aCC motor neuron (MN) and RP2 MN, were identified from one section of the flat body wall. We gently excised the surrounding fat cells, muscle fibers, and nearby neuron while leaving the entire connection–CNS → aCC + RP2 → NMJ–intact.
A different glass needle of similar specifications was then brought close and made adhere to the muscle side of the NMJ using a piezoelectric micro-actuator (NanoPZ PZC200; Newport, Irvine, CA) that provided nanometer resolution.
Pharmaceutical Drug
Cytochalasin D (50 μg/mL) was used for the disruption of F-actin. Nocodazole (15 μg/mL) and Colchicine (200 μM) were used for the disruption of MT. Y-27632 (110 μM) and ML-7 (225 μM) were used to inhibit the ROCK and MLCK pathways respectively. All chemicals were purchased from Sigma-Aldrich (St. Louis, MO). DMSO was added as a solvent and was maintained at a final concentration of less than 1%, tested to have no observable effect15. All drugs were diluted in Ca2+/Mg2+ free PBS. Drugs were added to the samples 3 minutes before the onset of measurements.
Microtubules Staining
The prepared embryos were extracted with BRB80-4mM EGTA-0.5% TX-100 (chemicals from Sigma, St Louis, MO) for 30 seconds to distinguish polymerized MT and fixed with 4% formaldehyde (28908; Fisher Scientific, Rockford, IL) for 15 minutes; blocked in 5% Bovine Serum Albumin (A9647; Sigma-Aldrich, St. Louis, MO) for 10 minutes; conjugated with mouse anti-α-tubulin (1:10; 12G10; DSHB, Iowa City, IA) for 60 minutes; tagged with Alexa 647 goat anti-mouse (1:200; A-21236; Fisher Scientific, Rockford, IL) for 30 minutes; and imaged with a scanning confocal microscope (LSM700; Carl Zeiss, Peabody, MA) afterwards. Samples were rinsed with PBST (PBS-0.1% Triton X-100) after each step. All steps were performed at room temperature.
Confocal Imaging
The embryos were inspected using a confocal microscope (LSM700; Zeiss, Oberkochen, Germany). The 488-nm laser was used to excite the GFP and emission light with wavelength larger than 488 nm was collected. Pinhole size was set to 1 a.u. A z-stack distance of 0.41 μm was maintained. A 40x/1.3 objective was used. We note that the number of images (ranges from 15–50) for any axon depends on its degree of out of plane tilt. We discarded samples with too much tilting that needed more than 50 images in the stack. The scan speed was sometimes adjusted so that an image stack could be obtained in around 80 seconds. The settings were kept consistent across all independent experiments. Image stacks were taken every 5 minutes. We found that this minimized photobleaching while allowing images to have adequate spatial and temporal resolution for our analysis.
Image Analysis
The collected images were post-processed first using ImageJ (U.S. National Institutes of Health, Bethesda, MD). The z-stacks were collapsed to single images by maximum intensity projection. The images were cropped to only the axon of interest which were then transferred to MATLAB (MathWorks, Natick, MA). A batch-enabled script was used to detect the edge of the axons, and subsequently performed diameter and area calculations (Fig. S1). The edge was traced by fitting a Gaussian profile to the intensity profile along the x-axis for every y (axial direction of axon). The 2 locations with maximum slope (\(\frac{{d}^{2}I(x)}{d{x}^{2}}=0\)) were reported for each y-coordinate. Connecting those points for all y-coordinates provided a discretized edge with axial resolution of a single pixel and lateral resolution of at least half a pixel. 3D images were generated by ImageJ to ensure that the distance between the 2 projected edges was representative of the diameter (Movie 1). Using the edge values, average diameters were computed over the same visible axonal length for each condition among different time points.
Spatial Light Interference Microscopy (SLIM)
SLIM was also used to examine the diameter and axonal mass transport. The sample preparation is similar to that previously described with slight modification to facilitate phase imaging. Specifically, we added a top cover slip above a PDMS spacer to seal off the sample and prevent evaporation. In addition, the space between the two cover slips (one supporting the embryo and the top cover) was filled with PBS. This offered flat interfaces for PBS to avoid any bias in the phase values during light transmission. Because of the top cover slip, no stretching manipulation was done to the samples imaged with SLIM.
In short, SLIM is a quantitative phase imaging27 technique that measures optical path length shifts in a phase contrast geometry25. In our implementation (CellVista SLIM, Phi Optics, Inc.), the pupil plane of a Zeiss Z1 is projected onto a spatial light modulator (SLM) that is then cycled in π/2 increments, essentially modulating the phase ring internal to the objective. Four such images are combined28 to produce a full-field phase-map, with a radian value at each pixel. All SLIM images used in this work were acquired with a 63x/1.4 objective (PN 420781-9910) and an sCMOS camera (Andor Zyla 5.5).
Each stack was used to reconstruct a single image to facilitate analysis (Fig. S2). The stack was first cropped to a region that only the axon of interest was visualized. Then, for each 5-pixel-times-width region along the axial direction of the axon, we found the stack plane with maximum gradient magnitude and defined the plane as the focal plane. The obtained plane numbers were then smoothed using the robust linear method and subsequently interpolated for every pixel along the longitudinal direction of the axon. These values were then rounded and used to obtained a reconstructed image from the image stack.
To evaluate diameter, we made use of the negative phase region at the boundaries of the axon (Fig. S3). Similar to the Gaussian fitting previously described, we obtained a profile, this time in phase values, for every pixel along the axial direction. We smoothed the profile and computed its difference function. The 2 maximum peaks (locations with maximum slope) in the difference function bound by the negative regions were defined as the boundary.
Data Availability
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
Results
In order to image axon diameter continuously, invasive surgery was performed on drosophila embryo to clean the tissues (including glial cells15) surrounding the axon until single axons could be observed. The neural membrane was genetically labelled with GFP for visualization purposes. Two imaging methods were used–confocal microscopy and SLIM. The preparations were similar with SLIM samples having a top cover slip to facilitate phase imaging (Fig. 1a). Fluorescence signal from the neural-membrane-bound GFP provided contrast in the confocal system, while phase changes provided contrast in SLIM. Methods unique to each imaging modality were used to (1) reconstruct an image stack into a single image, and (2) compute the diameter (and average phase for SLIM) from the reconstructed image (Fig. 1b). See materials and methods for detailed description. Axons were subjected to a series of stretching manipulations as depicted in Fig. 2.
Actin maintains a circumferential tension resisted by microtubules
Drugs with known specificity to actin filaments (cytochalasin D, cytoD) and MT (nocodazole and colchicine, noco/colch) were applied to the preparations 3 minutes before imaging commenced. The preparations were monitored under the two imaging modalities for 60 minutes (phase 1 in Fig. 2). We measure initial diameter at \({d}_{1i}=2.34\pm 0.44\) μm (confocal, N = 6) & \(3.31\pm 0.49\) μm (SLIM, N = 6). This corresponds to at least 20 pixels across the width of an axon (Fig. S4). We estimated that our gaussian fitting measurements should be accurate for at least 0.5 pixels. This gives a resolution of around 2.5%. The diameter changes were largely consistent between the two modalities (confocal imaging and SLIM). Disrupting actin filaments (Fig. 3a and b, red; Movie 2) led to an increase in average diameter (confocal: \({d}_{1f}/{d}_{1i}=1.11\pm 0.02\), \(N=8\); SLIM: \({d}_{1f}/{d}_{1i}=1.12\pm 0.04\), \(N=3\)), and disrupting MT (Fig. 3a and b, blue) led to a decrease in average diameter after 60 minutes of drug treatment (confocal: \({d}_{1f}/{d}_{1i}=0.87\pm 0.05\), \(N=6\); SLIM: \({d}_{1f}/{d}_{1i}=0.92\pm 0.02\), \(N=3\)). Control cases with PBS incubation (Fig. 3a and b, grey) showed a small increase (confocal: \({d}_{1f}/{d}_{1i}=1.01\pm 0.02\), \(N=6\); SLIM: \({d}_{1f}/{d}_{1i}=1.04\pm 0.01\), \(N=3\)) and slight fluctuations within our estimated accuracy of 2.5%. Spatial examination also revealed that diameter increase caused by actin disruption was consistent along the entire length of each axon (Fig. S5).
To test whether contractile forces are involved in diameter regulation, we treated the axons with myosin II disrupting drugs, Y-27632 and ML-7. These drugs were found to reduce contractility of axons along the longitudinal direction15. We observed diameter increase when axons were treated with Y-27632 (confocal: \({d}_{1f}/{d}_{1i}=1.12\pm 0.05\), \(N=3\); SLIM: \({d}_{1f}/{d}_{1i}=1.16\pm 0.08\), \(N=3\)) and ML-7 (\({d}_{1f}/{d}_{1i}=1.12\pm 0.06\), \(N=3\)) respectively (Fig. 3b and c). This implies that relaxation of tension results in increase in diameter.
Although the final magnitude of diameter increase (under cytoD or Y-27632 treatment) is similar between the 2 modalities, the time constant is not. We believe this can be attributed to the imaging and analysis methods used. In confocal imaging, the GFP signal comes from a membrane bound protein expressed only in neurons. While in SLIM, the contrast is derived from the content of the axons. Furthermore, we used a curve fitting algorithm in analyzing the data from confocal imaging to minimize noise, and such was difficult to realize in SLIM because of the many local intensity peaks. Previous work suggests that actin filaments are sensitive to cytoD treamtent in less than 10 minutes29, which is what we observed in confocal imaging.
These observations can be explained by contractility of actomyosin machinery along the circumferential direction of axons (Fig. 3d). When actin filaments/myosin II are disrupted, the circumferential tension is diminished. This leads to an imbalance of cell pressure and membrane tension, and, as a result, an inflation in diameter (and volume). On the other hand, when MT are disrupted, the polarity of the imbalance switches since there are now less restoring force against contractile actin leading to reduction in diameter. This proposition is interestingly similar to the case of axial axonal tension15, leading to our speculation that tension could be coupled in the axial and circumferential directions.
SLIM imaging revealed that the average phase (p) increased (\({p}_{f}/{p}_{i}=1.19\pm 0.20\), \(N=3\)) when actin was disrupted (Fig. 3e, red). Average phase remained unchanged (colch: \({p}_{f}/{p}_{i}=0.97\pm 0.11\), \(N=3\); Y-27632: \({p}_{f}/{p}_{i}=0.95\pm 0.08\), \(N=3\)) upon MT disruption (Fig. 3e, blue) or Y-27632 treatment (Fig. 3e, cyan). As phase correlates with mass density30, this suggests that the content that left upon MT disruption had similar density on average to the remaining content in the axon, while the new mass that had come in due to the inflation in diameter upon actin disruption was denser on average. Increase in diameter caused by Y-27632 did not lead to an influx of denser mass. This suggests that an inflation in diameter alone is not sufficient to cause the influx of denser mass; actin depolymerization is necessary.
The increase in phase upon actin disruption led us to investigate any side effects that CytoD itself might have caused. Upon a subsequent washout, axons that were treated with CytoD revert back to their original diameter (Fig. S4b). This suggests that CytoD did not cause any detrimental effect on axons permanently.
We further perform an analysis to understand the nature of the heavier mass coming in upon diameter inflation. We compared the normalized phase distribution of axons before and after cytoD treatment and identified a continuous range that led to the reported increase in average phase (Fig. S6a). The pixels that fell within the identified range show structures that resemble vesicles (Fig. S6b).
Axonal volume is conserved under fast stretch
To further examine whether axial and circumferential tension are coupled, we applied extra tension to the axon by stretching it (15–25% strain) from the NMJ side using a micro-pipette tip connected to a piezo-actuator (phase 2 in Fig. 2).
During initial fast stretch, mass flow in or out of axons is limited and volume should be conserved. We verified such conservation of volume during initial stretching by comparing theoretical diameter ratios to experimental values. Given the definition of strain (\(\varepsilon \)) as \(\frac{{\rm{\Delta }}l}{l}\), the stretch ratio (\(\lambda \)) is defined as:
The volume ratio for an axon modeled as a cylindrical rod is then:
If volume is conserved, then volume ratio \((\frac{{V}_{2f}}{{V}_{2i}})\) is 1. The diameter ratio (\({d}_{2f}/{d}_{2i}\)) is then:
Using Eq. 3, we can test volume conservation by comparing diameter and strain. Two strain measurements were used. One, termed global strain, traced the two ends of the axon. The other, termed local strain, traced two clearly identifiable points along the axon (Fig. 4a). The results for one axon are shown in Fig. 4b. We find, the diameter ratio is almost equal to \({\mathrm{(1}+\varepsilon )}^{-\frac{1}{2}}\) for both local and global strains. Thus Eq. 3 is satisfied experimentally, implying volume conservation. The close agreement between local strain and global strain suggests that the axonal strain is uniform along its length. In addition, it suggests that mechanical elastic properties of the axon is also uniform along its length. Data from three samples are shown in Table 1.
Circumferential tension from actin filaments reduces axon diameter overtime when a mechanical stretch is held
We monitor diameter changes for 30 minutes with the stretch held fixed (phase 3 in Fig. 2). The diameter continued to decrease (\({d}_{3f}/{d}_{3i}=0.88\pm 0.06\), \(N=6\)) for axons treated with PBS (Fig. 4c, green). This trend was not observed (\({d}_{3f}/{d}_{3i}=1.00\pm 0.04\), \(N=6\)) in axons with actin filaments disrupted (Fig. 4c, red). A smaller decrease was observed (\({d}_{3f}/{d}_{3i}=0.93\pm 0.03\), \(N=6\)) in axons with MT disrupted (Fig. 4c, blue). The reduction of diameter upon a sustained stretch, again, occurred along the entire length (Fig. S4). Thus volume of the axon under sustained stretch reduced in PBS and with MT disruption, but not with actin disruption.
Previous studies have shown that upon fast stretching, axial tension increases instantaneously, and then slowly relaxes (due to viscoelastic response to the applied tension) to a state that is more tensed (around 3-fold at 60% strain) than that prior to any stretch (rest tension)31; i.e., axial tension increases after stretch. This, together with our results that stretching led to diameter reduction (circumferential tension increases) driven by actin filaments, again suggests that axial tension and circumferential tension could be coupled.
We hypothesized that the actomyosin-driven reduction in diameter under sustained stretch was mainly due to the breakage of MT upon sudden mechanical stretch32, creating space for actin filaments to contract further. This is supported by the similar diameter reduction in MT-disrupted unstretched axons in phase 1 and untreated stretched axons in phase 3 (Fig. 3a, blue vs. Figure 4c, green). In addition, the smaller reduction in diameter in stretched axons with MT previously disrupted (Fig. 4c, blue) compared to untreated ones (Fig. 4c, green) further supports the argument; in these cases, MT had been disrupted and already resulted in a diameter reduction in phase 1. To test this hypothesis, staining experiments were performed to show the reduction of polymerized tubulin upon stretching (Fig. 4d).
Furthermore, as a control against prolonged saline incubation during phase 1, we performed stretching manipulations on a few axons immediately after embryo surgery. The observed diameter reduction showed no significant differences compared to that after 60 minutes of PBS incubation (Fig. 4c and e, green). Diameter reduction was not observed in axons not subjected to any stretch (Fig. 4e, grey) similar to results in Fig. 3a and b.
Circumferential tension from actin filaments reduces axon diameter when axon is returned to initial configuration
After the stretch was held for 30 minutes, some axons were brought back to their initial configuration. We called this process “unstretch” (phase 4 in Fig. 2). The axons first buckled when subjected to the unstretch process. They then slowly contracted to straighten again. Note that axons treated with cytoD do not fully contract, as also observed in other studies15, because actin-myosin contractility is hampered. For all instances, we waited 5 minutes after which their length did not visibly change. Axons left stretched served as control (Fig. 5a).
We then continued to monitor the diameter for another 30 minutes (phase 5 in Fig. 2). We called this phase “restore” for those axons returned to their taut, straight configuration. Previous studies have shown that axons build up significant tension31 that is actin-myosin dependent15 during this phase. We observed diameter reduction in restored axons (\({d}_{5f}/{d}_{5i}=0.90\pm 0.02\), \(N=6\)), regardless of whether phase 1 had previously been executed (Fig. 5a and b, magenta; Movie 3). Diameter did not change in control cases where axons were either never stretched (Fig. 5a, grey) or remained stretched without being restored (Fig. 5a, green), as explained in the inset of Fig. 5a. Reduction in diameter was significantly hampered (\({d}_{5f}/{d}_{5i}=0.97\pm 0.02\), \(N=5\)) in axons with actin filaments distupted (Fig. 5b, red).
However, axons with MT disrupted (Fig. 5b, blue) showed no diameter reduction (\({d}_{5f}/{d}_{5i}=0.97\pm 0.02\), \(N=5\)). We expected higher reduction in diameter since MT disruption results in higher longitudinal tension in axons12,33, and hence higher circumferential tension if there is coupling. The paradox can be resolved by considering phase 4, in which we waited 5 minutes for the axons to straighten after unstretch. It is known that force-free slackened axons with MT disruption straighten 3 times faster compared to axons with MT intact15. Volume conservation requires that soon after straightening diameter ratio increased to \({\lambda }^{-\mathrm{1/2}}\). After straightening, tension built up fast in MT-disrupted axons. Diameter reduced and arrived at a steady value before phase 5 began. This explains our experimental finding of \({d}_{4f}/{d}_{4i} < {\lambda }^{-\frac{1}{2}}\) (Table 2 & Fig. 5d, blue). Axons not treated with any drugs also straightened before phase 5 commenced. And diameter reduction (relative to the diameter from volume conservation calculations) in phase 4 was also observed in these axons (Table 2 and Fig. 5d, magenta); the reduction however continued in phase 5. This supports the argument that circumferential tension is coupled to axial tension: disrupting MT has been shown to speed up axial contraction and increase axial tension12,15,33, and here from our measurements we infer that MT disruption can lead to faster circumferential contraction.
We compared diameter reduction as a function of time with the evolution of tension in slackened axon measured previously31. Both data sets fitted well to an exponential curve in the form of \(A{e}^{-t/\tau }+C\) (Fig. 5d). Time constants (axial tension: 7.22 minutes; diameter: 7.11 minutes) were extracted from the fits. The time constant for tension development and diameter reduction are comparable, implying a common mechanism generating axial tension and reduction of diameter. This further supports that axial and circumferential tension could be coupled. Note that these time constants are greater than those observed in length shortening of slackened axons15, because axons continue to apply tension after becoming taut. This does not change the length, but can be captured using a force sensor31.
Discussion
In this paper we explored the biophysical factors that influence axonal diameter in motor neurons of embryonic drosophila. We used two independent methods, confocal microscopy and SLIM imaging, to measure axonal diameter. We demonstrated earlier that after synaptogenesis axons tends to contract and hence develop tension along the longitudinal direction. Actin and myosin II are involved in generating the longitudinal tension15. Here we show that acto-myosin machinery is involved in generating circumferential tension as well along the entire length of the axon. This tension originates from the contractility of cortical actin, which in turn applies a compressive force on the MT. The force balance between cortical actin and microtubule results in an equilibrium diameter of the axon (Fig. 6). Thus, when MT are disrupted, diameter decreases; when actin is disrupted or myosin II is inhibited, diameter increases. We further show that longitudinal and circumferential tension are coupled. They share similar time constants of evolution; i.e., times to generate longitudinal tension and to contract the diameter to their respective steady values are similar. This suggests a common mechanistic origin for both. However, the detailed cytoskeletal architecture that gives rise to the circumferential contractility of embryonic axons remains to be resolved.
Circumferential contractile forces are found in multiple biological processes. For example, actomyosin rings are critical for wound healing34,35 and cytokinesis36,37. In both cases, they exert a circumferential tension to do work and drive the dynamics of the processes. Notably, these other rings are much larger in size and can span several cells; they are also more dynamic than those observed in axons38. Furthermore, the ring structure of actin has not yet been observed in myelinated axons, except that at the nodes of Ranvier5. drosophila axons are not myelinated, but glial cells still form an insulating layer around them as early as stage 1539. This limits the ability to super-resolve structure of actin (and other proteins) because of multiple scattering events5. Nonetheless, most evidence support the existence of actin ring in peripheral axons. It has been shown that axonal diameter increases when adducin8, an actin-capping protein that is thought to link the actin and spectrin in the periodic membrane skeleton, is disrupted; it is unclear though how adducin can help regulate diameter. The present work provides new insights to the mechanism by which actomyosin network can maintain structural integrity and regulate shape of axons–through the coupled axial and circumferential tension.
It is important to note that we used change of diameter of axons and the effect of force relaxing drugs to infer circumferential tension, given that force and deformation (change of diameter) are related through the cytoskeletal elasticity of the axons. Since these material properties are not known, we cannot quantify the circumferential forces. There is no direct means available to measure circumferential tension. The nano-Newton force probe used to measure longitudinal force of the axons13 could not be used to measure circumferential force. However, our data supports a model where longitudinal and circumferential tensions are coupled (Table 3), although the precise nature of this coupling remains elusive.
Our SLIM experiments demonstrated that mass displaced during diameter reduction (following MT disruption) did not change the density of the axon. Images from electron microscopy show that axons are MT-rich3. These 2 observations together suggest that the displaced mass is composed of depolymerized MT and their associated proteins. Mass that entered the axon during diameter dilation after actin disruption, on the other hand, had higher density and resulted in new structures with vesicle-like morphology based on our phase histogram analysis. One plausible explanation is that these new structures were originally vesicles scaffolded by an actin-rich network in the presynaptic terminal40, which upon actin disruption, are released into the axon. Yet, we cannot exclude the possibility of vesicles/cargo from other sources. Channels gating and vesicles fusion can also regulate mass; it has been shown that membrane tension provided by actin dynamics is a key factor in these processes35,41. We, however, did not observe exocytosis/endocytosis events in our experiments, which could be due to insufficient spatial-temporal resolution.
The reduction in diameter under stretch might seem counterintuitive to normal development, since one would expect the axon to increase its diameter during development. In fact, several in vitro experiments have shown that axons, when towed, would grow both axially and laterally19,42; the growth is dependent on new MT formation43. In these studies, however, the stretch is imposed slowly and gradually throughout the course of the experiment, while in our case the time from no stretch to full stretch (120% of original length) is usually in less than a minute. This seems to suggest that stretching with different strain rates can result in different MT dynamics; i.e., when stretch is applied at a higher rate than the polymerization process, MT can break and subsequently disassemble32, which occurs at a faster time scale44.
Axonal diameter is a physiologically relevant parameter, since conduction speed of action potential along the axons scales with the diameter for both healthy and pathological neurons45. Nerve atrophy results in reduction of axonal diameter and a corresponding reduction in conduction speed. Hence, significant effort has been directed to measuring axonal and nerve diameter using multiple methods including electron microscopy46, and diffusion MRI47. However, how axons maintain their diameter has gained limited attention. This work reveals a biophysical mechanism that maintains the diameter.
References
Kandel, E., Schwartz, J., Jessell, T., Siegelbaum, S. & Hudspeth, A. J. Principles of Neural Science, Fifth Edition (McGraw Hill Professional, 2012).
Conde, C. & Cáceres, A. Microtubule assembly, organization and dynamics in axons and dendrites. Nature reviews. Neuroscience 10, 319–32 (2009).
Hirokawa, N. Cross-linker system between neurofilaments, microtubules, and membranous organelles in frog axons revealed by the quick-freeze, deep-etching method. The Journal of cell biology 94, 129–42 (1982).
Xu, K., Zhong, G. & Zhuang, X. Actin, spectrin, and associated proteins form a periodic cytoskeletal structure in axons. Science (New York, N.Y.) 339, 452–456 (2013).
D’Este, E., Kamin, D., Göttfert, F., El-Hady, A. & Hell, S. W. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell reports 10, 1246–51 (2015).
Leite, S. C. & Sousa, M. M. The neuronal and actin commitment: Why do neurons need rings? Cytoskeleton (Hoboken, N. J.) 73, 424–34 (2016).
Kevenaar, J. T. & Hoogenraad, C. C. The axonal cytoskeleton: from organization to function. Frontiers in molecular neuroscience 8, 44 (2015).
Leite, S. C. et al. The Actin-Binding Protein α-Adducin Is Required for Maintaining Axon Diameter. Cell reports 15, 490–8 (2016).
Pollard, T. D. & Cooper, J. A. Actin, a central player in cell shape and movement. Science (New York, N.Y.) 326, 1208–12 (2009).
Vogel, V. & Sheetz, M. Local force and geometry sensing regulate cell functions. Nature reviews. Molecular cell biology 7, 265–75 (2006).
Lamoureux, P., Buxbaum, R. E. & Heidemann, S. R. Direct evidence that growth cones pull. Nature 340, 159–62 (1989).
Dennerll, T. J., Joshi, H. C., Steel, V. L., Buxbaum, R. E. & Heidemann, S. R. Tension and compression in the cytoskeleton of PC-12 neurites. II: Quantitative measurements. The Journal of cell biology 107, 665–74 (1988).
Siechen, S., Yang, S., Chiba, A. & Saif, T. Mechanical tension contributes to clustering of neurotransmitter vesicles at presynaptic terminals. Proceedings of the National Academy of Sciences of the United States of America 106, 12611–6 (2009).
Xu, G. et al. Axons pull on the brain, but tension does not drive cortical folding. Journal of biomechanical engineering 132, 071013 (2010).
Tofangchi, A., Fan, A. & Saif, M. T. A. Mechanism of Axonal Contractility in Embryonic Drosophila Motor Neurons In Vivo. Biophysical journal 111, 1519–1527 (2016).
Bray, D. Axonal growth in response to experimentally applied mechanical tension. Developmental biology 102, 379–89 (1984).
Smith, D. H., Wolf, J. A. & Meaney, D. F. A new strategy to produce sustained growth of central nervous system axons: continuous mechanical tension. Tissue engineering 7, 131–9 (2001).
Pfister, B. J., Bonislawski, D. P., Smith, D. H. & Cohen, A. S. Stretch-grown axons retain the ability to transmit active electrical signals. FEBS letters 580, 3525–31 (2006).
Lamoureux, P., Heidemann, S. R., Martzke, N. R. & Miller, K. E. Growth and elongation within and along the axon. Developmental neurobiology 70, 135–49 (2010).
Suter, D. M. & Miller, K. E. The emerging role of forces in axonal elongation. Progress in neurobiology 94, 91–101 (2011).
Koser, D. E. et al. Mechanosensing is critical for axon growth in the developing brain. Nature neuroscience 19, 1592–1598 (2016).
Fan, A., Stebbings, K. A., Llano, D. A. & Saif, T. Stretch induced hyperexcitability of mice callosal pathway. Frontiers in cellular neuroscience 9, 292 (2015).
Ahmed, W. W. et al. Mechanical tension modulates local and global vesicle dynamics in neurons. Cellular and molecular bioengineering 5, 155–164 (2012).
Chen, B. M. & Grinnell, A. D. Integrins and modulation of transmitter release from motor nerve terminals by stretch. Science (New York, N.Y.) 269, 1578–80 (1995).
Wang, Z. et al. Spatial light interference microscopy (SLIM). Optics express 19, 1016–26 (2011).
Budnik, V., Gorczyca, M. & Prokop, A. Selected methods for the anatomical study of Drosophila embryonic and larval neuromuscular junctions. International review of neurobiology 75, 323–65 (2006).
Popescu, G. Quantitative Phase Imaging of Cells and Tissues (McGraw Hill Professional, 2011).
Popescu, G. et al. Fourier phase microscopy for investigation of biological structures and dynamics. Optics letters 29, 2503–5 (2004).
Rotsch, C. & Radmacher, M. Drug-induced changes of cytoskeletal structure and mechanics in fibroblasts: an atomic force microscopy study. Biophysical journal 78, 520–35 (2000).
Popescu, G. et al. Optical imaging of cell mass and growth dynamics. American journal of physiology. Cell physiology 295, C538–44 (2008).
Rajagopalan, J., Tofangchi, A. & Saif, M. T. A. Drosophila neurons actively regulate axonal tension in vivo. Biophysical journal 99, 3208–15 (2010).
Tang-Schomer, M. D., Patel, A. R., Baas, P. W. & Smith, D. H. Mechanical breaking of microtubules in axons during dynamic stretch injury underlies delayed elasticity, microtubule disassembly, and axon degeneration. FASEB journal: official publication of the Federation of American Societies for Experimental Biology 24, 1401–10 (2010).
Joshi, H. C., Chu, D., Buxbaum, R. E. & Heidemann, S. R. Tension and compression in the cytoskeleton of PC 12 neurites. The Journal of cell biology 101, 697–705 (1985).
Brugués, A. et al. Forces driving epithelial wound healing. Nature physics 10, 683–690 (2014).
Saias, L. et al. Decrease in Cell Volume Generates Contractile Forces Driving Dorsal Closure. Developmental cell 33, 611–21 (2015).
Pelham, R. J. & Chang, F. Actin dynamics in the contractile ring during cytokinesis in fission yeast. Nature 419, 82–6 (2002).
Mishra, M. et al. In vitro contraction of cytokinetic ring depends on myosin II but not on actin dynamics. Nature cell biology 15, 853–9 (2013).
Zhong, G. et al. Developmental mechanism of the periodic membrane skeleton in axons. eLife 3 (2014).
Banerjee, S. & Bhat, M. A. Glial ensheathment of peripheral axons in Drosophila. Journal of neuroscience research 86, 1189–98 (2008).
Hirokawa, N., Sobue, K., Kanda, K., Harada, A. & Yorifuji, H. The cytoskeletal architecture of the presynaptic terminal and molecular structure of synapsin 1. The Journal of cell biology 108, 111–26 (1989).
Wen, P. J. et al. Actin dynamics provides membrane tension to merge fusing vesicles into the plasma membrane. Nature communications 7, 12604 (2016).
Pfister, K. K. Cytoplasmic dynein and microtubule transport in the axon: the action connection. Molecular neurobiology 20, 81–91 (1999).
Zheng, J., Buxbaum, R. E. & Heidemann, S. R. Investigation of microtubule assembly and organization accompanying tension-induced neurite initiation. Journal of cell science 104(Pt 4), 1239–50 (1993).
Grishchuk, E. L., Molodtsov, M. I., Ataullakhanov, F. I. & McIntosh, J. R. Force production by disassembling microtubules. Nature 438, 384–8 (2005).
Gillespie, M. J. & Stein, R. B. The relationship between axon diameter, myelin thickness and conduction velocity during atrophy of mammalian peripheral nerves. Brain research 259, 41–56 (1983).
Liewald, D., Miller, R., Logothetis, N., Wagner, H.-J. & Schüz, A. Distribution of axon diameters in cortical white matter: an electron-microscopic study on three human brains and a macaque. Biological cybernetics 108, 541–57 (2014).
Kamiya, K. et al. Axon diameter and intra-axonal volume fraction of the corticospinal tract in idiopathic normal pressure hydrocephalus measured by q-space imaging. PloS one 9, e103842 (2014).
Acknowledgements
We would like to thank Jagannathan Rajagopalan at Arizona State University for providing the axial tension data in Fig. 5d, the Smith-Bolton group at the University of Illinois for fly supplies, and Austin Cyphersmith and Mayandi Sivaguru at the Carl R. Woese Institute for Genomic Biology for help in setting up the confocal imaging. This work was supported by the National Institutes of Health (NINDS NS063405-01), the National Science Foundation (Science and Technology Center on Emergent Behaviors in Integrated Cellular Systems (EBICS) Grant, CBET-0939511, CMMI-1300808, DGE-1144245, and DGE-0965918), and the Croucher Foundation.
Author information
Authors and Affiliations
Contributions
A.F., T.S. conceived the project. A.F., A.T., T.S. designed the experiments. A.F., A.T. performed the experiments. M.K., G.P. designed and performed the SLIM imaging. A.F., A.T., M.K. contributed to data analysis. A.F., T.S. wrote the paper. All authors contributed in interpreting the data and editing the manuscript. No competing financial interest.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Fan, A., Tofangchi, A., Kandel, M. et al. Coupled circumferential and axial tension driven by actin and myosin influences in vivo axon diameter. Sci Rep 7, 14188 (2017). https://doi.org/10.1038/s41598-017-13830-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-13830-1
This article is cited by
-
Importin 13-dependent axon diameter growth regulates conduction speeds along myelinated CNS axons
Nature Communications (2024)
-
A mathematical model for axonal transport of large cargo vesicles
Journal of Mathematical Biology (2024)
-
Unraveling axonal mechanisms of traumatic brain injury
Acta Neuropathologica Communications (2022)
-
Cytoskeletal assembly in axonal outgrowth and regeneration analyzed on the nanoscale
Scientific Reports (2022)
-
The role of the membrane-associated periodic skeleton in axons
Cellular and Molecular Life Sciences (2021)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.