Abstract
The quality assurance program presented here provides a means to maximize and maintain the performance of individual flow cytometers in a facility. To optimize performance, we recommend performing all three steps (optimization, calibration and standardization) in this program when a new flow cytometer is installed or whenever the flow cytometer's optical path is altered (e.g., lasers, filters or detectors are replaced). The complete process requires 3–4 h. On a more frequent basis, only a subset of these procedures need to be performed as a part of daily maintenance routines. The data generated can be tracked to monitor the instrument and determine whether service is needed. In addition, the data can provide a metric for whether repairs and upgrades have improved or harmed performance, and for future instrument-to-instrument comparisons. In sum, the procedures presented here represent an updated framework for optimizing, calibrating and standardizing a flow cytometer for daily use.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Bendall, S. et al. A deep profiler's guide to cytometry. Trends Immunol. 33, 323–332 (2012).
Chattopadhyay, P.K. et al. Cytometry: today's technology and tomorrow's horizons. Methods 57, 251–258 (2012).
Chattopadhyay, P.K. et al. Quantum dot semiconductor nanocrystals for immunophenotyping by polychromatic flow cytometry. Nat. Med. 12, 972–977 (2006).
Le Meur, N. et al. Data quality assessment of ungated flow cytometry data in high throughput experiments. Cytometry A 71, 393–403 (2007).
Harvath, L. Quality control in clinical flow cytometry. Pathol. Immunopathol. Res. 7, 338–344 (1988).
Horan, P.K., Muirhead, K.A. & Slezak, S.E. Standards and controls in flow cytometry. in Flow Cytometry and Sorting, 2nd edn. (eds. Melamed, M.R., Lindmo, T. & Mendelsohn M.L.) 397–414 (Wiley-Liss, 1990).
Shapiro, H.M. Practical Flow Cytometry (Wiley-Liss, 2003).
Perfetto, S.P., Ambrozak, D., Nguyen, R., Chattopadhyay, P. & Roederer, M. Quality assurance for polychromatic flow cytometry. Nat. Protoc. 1, 1522–1530 (2006).
Schwartz, A., Marti, G.E., Poon, R., Gratama, J.W. & Fernandez-Repollet, E. Standardizing flow cytometry: a classification system of fluorescence standards used for flow cytometry. Cytometry 33, 106–114 (1998).
Schwartz, A., Fernandez Repollet, E., Vogt, R. & Gratama, J.W. Standardizing flow cytometry: construction of a standardized fluorescence calibration plot using matching spectral calibrators. Cytometry 26, 22–31 (1996).
Schwartz, A. et al. Formalization of the MESF unit of fluorescence intensity. Cytometry B Clin. Cytom. 57, 1–6 (2004).
Zenger, V.E., Vogt, R., Mandy, F., Schwartz, A. & Marti, G.E. Quantitative flow cytometry: inter-laboratory variation. Cytometry 33, 138–145 (1998).
Chase, E.S. & Hoffman, R.A. Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity. Cytometry 33, 267–279 (1998).
Author information
Authors and Affiliations
Contributions
S.P.P. conceived and defined experiments, analyzed data and wrote the manuscript. D.A. and R.N. performed experiments and analyzed data. P.K.C. and M.R. designed experiments and wrote the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
About this article
Cite this article
Perfetto, S., Ambrozak, D., Nguyen, R. et al. Quality assurance for polychromatic flow cytometry using a suite of calibration beads. Nat Protoc 7, 2067–2079 (2012). https://doi.org/10.1038/nprot.2012.126
Published:
Issue Date:
DOI: https://doi.org/10.1038/nprot.2012.126
This article is cited by
-
Assessment of a multisite standardized biospecimen collection protocol for immune phenotyping in neurodevelopmental disorders
Scientific Reports (2023)
-
Deep Immunophenotyping of Human Whole Blood by Standardized Multi-parametric Flow Cytometry Analyses
Phenomics (2023)
-
Low glucose metabolite 3-phosphoglycerate switches PHGDH from serine synthesis to p53 activation to control cell fate
Cell Research (2023)
-
Mapping Cell Phenomics with Multiparametric Flow Cytometry Assays
Phenomics (2022)
-
The aldolase inhibitor aldometanib mimics glucose starvation to activate lysosomal AMPK
Nature Metabolism (2022)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.