Abstract
AT the recent Institute of Physics Conference at Leeds, I communicated a rule which I have found useful for calculating the relative humidity direct from readings of the ventilated wet- and dry-bulb hygrometer. Expressed so as to facilitate rapid mental calculation, it is as follows: to calculate the percentage relative humidity, express three times the wet-bulb depression (° F.) as a percentage of the dry-bulb reading, and subtract from 100; or symbolically:
Similar content being viewed by others
Article PDF
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
TURNER, A. Rapid Calculation of Relative Humidity from Readings of the Sling Hygrometer. Nature 143, 897 (1939). https://doi.org/10.1038/143897b0
Issue Date:
DOI: https://doi.org/10.1038/143897b0
Comments