Abstract
VERY little attention has been paid in the past to the accurate measurement of the optical intensity of spectral lines in vacuum tubes under different conditions, probably on account of the considerable experimental difficulties. Hence I may, perhaps, be allowed to indicate a relation I have obtained between the optical intensity, current strength, and pressure of the glowing gas. Throughout the whole experimental range, using the so-called “electrode less” tube—with wholly external mercury electrodes, when the current is of a slowly oscillating character—the optical intensity, with an end-on tube, is accurately proportional to the readings of a thermo-galvanometer in series, and over a more limited range of measurement, at constant current, is inversely proportional to the pressure of the gas.
Similar content being viewed by others
Article PDF
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
COWPER, A. Intensity of Spectrum Lines. Nature 77, 248 (1908). https://doi.org/10.1038/077248d0
Issue Date: