Abstract
New developments in clinical psychophysics allow a non-invasive assessment of visual function which may otherwise not be possible. Measurements of spatial and temporal contrast sensitivity functions, perimetric rod and cone sensitivity, colour vision testing, and newer tests such as hyperacuity thresholds may provide information about the mechanism of an abnormality, allow earlier detection of damage, determination of retinal function in the presence of ocular media disturbances, and allow more sensitive detection of the effects of treatment on visual function. Some methods are more effective in screening or monitoring patients over time while others can be used as research tools to investigate the underlying causes of visual dysfunction. Emerging technologies such as those based on video displays and computer generated graphics and advances in methodology provide potential for new applications. The selection of which aspect of visual function to test depends on the condition (e.g., retinal degeneration or glaucoma), the goals of the investigation, and the facilities available. These non-invasive methods can provide accurate information about retinal function and further improve our ability to quantify and document this most important aspect of the eye - its role in visual function.
Similar content being viewed by others
Article PDF
References
Kersten D, Hess RF, Plant GT . Assessing contrast sensitivity behind cloudy media. Clin Vision Sci 1988; 2: 143–58.
Abrahamsson M, Frisen M, Sjöstrand J . Statistical evaluation of contrast sensitivity function (CSF) in visual disorders — can diagnostic indices of CSF and acuity data be clinically useful? Clin Vision Sci 1988; 2: 159–67.
Rubin GS . Reliability and sensitivity of clinical contrast sensitivity tests. Clin Vision Sci 1988; 2: 169–77.
Tytla ME, and Buncic JR . Optic nerve compression impairs low spatial frequency vision in man. Clin Vision Sci 1988; 2: 179–86.
Pelli DG, Robson JG, Wilkins AJ . The design of a new letter chart for measuring contrast sensitivity. Clin Vision Sci 1988; 2: 187–99.
Wilkins AJ, Delia Sala S, Somazzi L, Nimmo-Smith I . Age-related norms for the Cambridge Low Contrast Gratings, including details concerning their design and use. Clin Vision Sci 1988; 2: 201–12.
Arden GB . Testing contrast sensitivity in clinical practice. Clin Vision Sci 1988; 2: 213–34.
Barbur JL . Spatial frequency specific measurements and their use in clinical psychophysics. Clin Vision Sci 1988; 2: 225–33.
Regan D . Low-contrast charts and sinewave grating tests in ophthalmological and neurological disorders. Clin Vision Sci 1988; 2: 235–50.
Ross JE, Bron AJ, Reeves BC, Emmerson PG . Detection of optic nerve damage in ocular hypertension. Br J Ophthalmol 1985; 69: 897–903.
Hess RF and Plant GT . Optic Neuritis. Cambridge. Cambridge University Press, 1986.
Apkarian P, Tjissen R, Spekreijse H, Regan D . Origin of notches in CSF: optical or neural? Inv Ophthalmol Vis Sci 1987; 28: 607–12.
Kowal L . The contrast sensitivity function and childhood amblyopia. Am J Ophthalmol 1987; 104: 671–2.
Rogers GL, Bremer DL, Leguire LE . Reply to the contrast sensitivity function and childhood amblyopia. Am J Ophthalmol 1987; 104: 672–3.
Bachman WG, and Behar I . The effect of cycloplegia on the visual contrast sensitivity function. Aviat Space Environ Med 1987; 58: 339–42.
Campbell FW and Green DG . Optical and retinal factors affecting visual resolution. J Physiol Lond 1965; 181: 576–93.
Green DG . Testing the vision of cataract patients by means of laser-generated intereference fringes. Science 1970; 168: 1240–2.
Cavonius CR, and Hilz RA technique for testing visual function in the presence of opacities. Invest Ophthalmol Vis Sci 1973; 12: 933–6.
Tylder CW . Specific deficits of flicker sensitivity in glaucoma and ocular hypertension. Invest Ophthalmol Vis Sci 1981; 20: 204–12.
Tyler CW, Ernst W, Lyness AL . Photopic flicker sensitivity losses in simplex and multiplex retinitis pigmentosa. Invest Ophthalmol Vis Sci 1984; 25: 1035–42.
Ernst W, Clover G, Faulkner DG . X-linked retinitis pigmentosa: reduced rod sensitivity to flicker in heterozygous females. Invest Ophthalmol Vis Sci 1982; 20: 812–6.
Alexander KR and Fishman GA . Rod-cone interaction in flicker perimetry. Br J Ophthalmol 1984; 68: 303–9.
Arden GB and Hogg CR . Rod-cone interaction and analysis of retinal disease. Br J Ophthalmol 1985; 69: 404–15.
Greve EL and Heijl A . Seventh International Visual Field Symposium. Dordrecht, Martinus Nijhoff/Dr W Junk, 1987: 675.
Silverstone DE and Hirsch J . Automated visual field testing. Norwalk, Conn. Appleton-Century-Crofts, 1986: 308.
Atchison DA . Effect of defocus on visual field measurement. Ophthal Physiol Opt 1987; 7: 259–65.
Weinreb RN, and Perlman JP . The effect of refractive correction on perimetric thresholds. Am J Ophthalmol 1986; 101: 706–9.
Wood JM, Wild JM, Hussey MK, Crews SJ . Serial examination of the normal visual field using Octopus automated projection perimetry: Evidence for a learning effect. Acta Ophthalmol 1987; 65: 326–33.
Lewis RA, Johnson CA, Keltner JL, Labermeier PK . Variability of quantitative automated perimetry in normal observers. Ophthalmology 1986; 93: 878–81.
Jaffe GJ, Alvarado JA, Juster RP . Age-related changes of the normal visual Field. Arch Ophthalmol 1986; 104: 1021–5.
Wilensky JT, Mermelstein JR, Siegel HG . The use of different-sized stimuli in automated perimetry. Am J Ophthalmol 1986; 101: 710–13.
Stunner J . What do glaucomatous visual fields really look like in fine-grid computerized profile perimetry. Dev Ophthalmol 1985; 12: 1–47.
Wood JM, Wild JM, Crews SJ . Induced intraocular light scatter and the sensitivity gradient of the normal visual field. Graefe's Arch Clin Exp Ophthalmol 1987; 225: 369–73.
Brenton RS and Argus WA . Fluctuations on the Humphrey and Octopus perimeters. Invest Ophthalmol Vis Sci 1987; 28: 767–71.
Wood JM, Wild JM, Bullimore MA, Gilmartin B . Factors affecting the normal perimetric profile derived by automated static threshold LED perimetry. I. Pupil size. Ophthal Physiol Opt 1988; 8: 26–31.
McCluskey DJ, Douglas JP, O'Connor PS, Story K, Ivy LM, Harvey JS . The effect of pilocarpine on the visual field in normals. Ophthalmology 1986; 93: 843–6.
Stewart WC, Shields MB, Ollie AR . Peripheral visual field testing by automated kinetic perimetry in glaucoma. Arch Ophthalmol 1988; 106: 202–6.
Wirtschafter JD . Examination of the peripheral visual field. Arch Ophthalmol 1987; 105: 761–2.
Capriolo J, Sears M, Miller JM . Patterns of early visual field loss in open-angle glaucoma. Am J Ophthalmol 1987; 103: 512–7.
Katz J and Sommer A . Similarities between the visual fields of ocular hypertensive and normal eyes. Arch Ophthalmol 1986; 104: 1648–51.
Drance SM, Douglas GR, Airaksinen PJ, Schulzer M, Hitchings RA . Diffuse visual field loss in chronic open-angle and low tension glaucoma. Am J Ophthalmol 1987; 104: 577–80.
Lewis RA and Johnson CA . Early detection of glaucomatous damage. I. Psychophysical disturbances. Surv Ophthalmol 1985; 30: 111–7.
Stampfer RL . The effect of glaucoma on central visual function. Trans Am Ophthalmol Soc 1984; 82: 792–826.
Wild JM, Wood JM, Worthington FM, Crews SJ . Some concepts on the use of three-dimensional plots for the representation of differential sensitivity. Doc Ophthalmol 1987; 65: 423–32.
Johnson CA, Keltner JL, Lewis RA . Automated kinetic perimetry: and efficient method of evaluating peripheral visual Field loss. Appl Optics 1987; 26: 1409–14.
Phelps CD . Acuity perimetry and glaucoma. Trans Am Ophthalmol Soc 1984; 82: 753–91.
Drum B, Armaly MF, Huppert W . Scotopic sensitivity loss in glaucoma. Arch Ophthalmol 1986; 104: 712–17.
Frisen L . a computer-graphics visual field screener using high-pass, spatial frequency resolution targets and multiple feedback devices. In Greve EL and Heyl A, eds. Seventh International Visual Field Symposium 1986; 441–446.
Fitzke FW, Poinoosawmy D, Ernst W, Hitchings RA . Peripheral Displacement Thresholds in Normals Ocular Hypertensives, and Glaucoma. In Greve EL and Heyl A, eds. Seventh Int. Visual Field Symposium 1986; 447–452.
Fletcher R and Voke J . Defective colour vision. Bristol and Boston, Adam Hilger Ltd, 1985: 608.
Verriest G, ed. Colour Vision Deficiencies VIII. Martinus Nijhoff/Dr W Junk, 1987: 524.
Boynton RM . Colour vision. Ann Rev Psychol 1988; 39: 69–100.
Sample PA, Weinreb RN, Boynton RM . Acquired dyschromatopsia in glaucoma. Surv Ophthalmol 1986; 31: 54–64.
Airaksinen PJ, Lakowski R, Drance SM, Price M . Color vision and retinal nerve fibre layer in early glaucoma. Am J Ophthalmol 1986; 101: 208–13.
Breton ME and Krupin T . Age covariance between 100-hue colour scores and quantitative perimetry in primary open angle glaucoma. Arch Ophthalmol 1987; 105: 642–5.
Chisholm IA . Area of visual field and colour discrimination combined as a predictor of chronic open-angle glaucoma. Can J Ophthalmol 1988; 23: 8–10.
Heron G, Adams AJ, Husted R . Foveal and non-foveal measures of short wavelength sensitive pathways in glaucoma and ocular hypertension. Ophthal Physiol Opt 1987; 7: 403–4.
Adams AJ, Heron G, Husted R . Clinical measures of central vision function in glaucoma and ocular hypertension. Arch Ophthalmol 1987; 105: 782–7.
Heron G, Adams AJ, Husted R . Central visual fields for short wavelength sensitive pathways in glaucoma and ocular hypertension. Inv Ophthalmol Vis Sci 1988; 29: 64–72.
Eisner A, Fleming SA, Klein ML, Mauldin WM . Sensitivities in older eyes with good acuity: cross sectional norms. Inv Ophthalmol Vis Sci 1987; 28: 1824–31.
Applegate RA, Adams AJ, Cavender JC, Zisman F . Early colour vision changes in age-related maculopathy. Appl Optics 1987; 26: 1458–62.
Adams AJ, Zisman F, Ai E, Bresnick G . Macular edema reduces B cone sensitivity in diabetics. Appl Optics 1987; 26: 1455–7.
Pokorny J, Smith VC, Lutze M . Ageing of the human lens. Appl Optics 1987; 26: 1437–40.
Knoblauch K, Saunders F, Kusuda M, Hynes R, Podgor M, Higgins KE, de Monasterio FM . Age and illuminance effects in the Farnsworth-Munsell 100-hue test. Appl Optics 1987; 26: 1441–8.
Massof RW and Finkelstein D . Rod sensitivity relative to cone sensitivity in in retinitis pigmentosa. Invest Ophthalmol Vis Sci 1979; 18: 263–72.
Lyness AL, Ernst W, Quinlan MP, Clover GM, Arden GB, Carter RM, Bird AC, Parker JA . A clinical, psychophysical, and electroretino-graphic survey of patients with autosomal dominant retinitis pigmentosa. Br J Ophthalmol 1985; 69: 326–39.
Ernst W, Faulkner DJ, Hogg CR, Powell DJ, Arden GB, Vaegan. An automated static perimeter/adaptometer using light emitting diodes. Br J Ophthalmol 1983; 67: 431–42.
Apathy PP, Jacobson SG, Nghiem-phu L, Knighton RW, Parel J-M . Computer-aided analysis in automated dark-adapted static perimetry. In Greve EL and Heyl A, eds. Seventh Int Visual Field Symposium 1986; 277–284.
Mayer DL, Fulton AB, Cummings MF . Visual fields of infants assessed with a new perimetric technique. Invest Ophthalmol and Vis Sci 1988; 29: 452–9.
Ernst W, Kemp CM, Arden GB, Moore AT, Bryan S . Functional Heterogeneity in Retinitis Pigmentosa, in Retinal Signal Systems, Degenerations and Transplants, eds. E Agardh and B Ehinger, The Netherlands, Elsevier, 1986.
Bird AC . Clinical investigation of retinitis pigmentosa, In: Degenerative Retinal Disorders: Clinical and Laboratory Investigations Ed. JG Hollyfield, RE Anderson, and MM LaVail. Alan R Liss, New York, 1987 pp. 3–20.
Kemp CM . Fundus reflectometric investigation of retinitis pigmentosa. Adv Biosciences 1987; 62: 169–76.
Kemp CM, Jacobson SG, Faulkner DJ, Walt WW . Visual function and rhodopsin levels in humans with vitamin A deficiency. Exp Eye Res 1988; 46: 185–97.
Kemp CM, Jacobson SG, Faulkner DJ . Two types of visual dysfunction in autosomal dominant retinitis pigmentosa. Invest Ophlhalmol Vis Sci 1988; 29 (in press).
Fulton AB and Hansen RM . The relation of rhodopsin and scotopic retinal sensitivity in sector retinitis pigmentosa. Am J Ophlhalmol 1988; 105: 132–40.
Fulton AB and Hansen RM . The relation of rhodopsin and scotopic retinal sensitivity in choroi-deremia. Am J Ophthalmol 1987; 105: 524–31.
Kemp CM, Jacobson SG, Faulkner DJ, Walt RW . Visual function and rhodopsin levels in humans with vitamin A deficiency. Exp Eye Res 1988; 46: 185–97.
Capon MRC, Polkinghorne PJ, Fitzke FW, Bird AC . Sorsby's Pseudoinflammatory Macula Dystrophy — Sorsby's Fundus Dystrophies. Eye 1988; 2: 114–22.
Alexander KR and Fishman GA . Prolonged Rod Dark Adaptation in Retinitis Pigmentosa. Br J Ophthalmol 1984; 68: 561–9.
Ernst W and Moore AR . Heterogeneity, anomalous adaptation and incomplete penetrance in autosomal dominant retinitis pigmentosa. Adv Biosciences 1987; 62: 115–28.
Highman VN and Weale RA . Rhodopsin density and visual threshold in retinitis pigmentosa. Am J Ophthalmol 1973; 75: 822–32.
Sternberg P, Fitzke FW, Finkelstein D . Cyclic Macular Edema. Am J Ophthalmol 1982; 94: 664–9.
Sandberg MA, Baruzzi CM, Hanson AH, Berson EL . Rod ERG diurnal rhythm in some patients with dominant retinitis pigmentosa. Inv Ophthalmol and Vis Sci 1988; 29: 494–8.
Eisner A, Fleming SA, Klein ML, Mauldin WM . Sensitivities in older eyes with good acuity: eyes whose fellow eye has exudative AMD. Inv Ophthalmol and Vis Sci 1987; 28: 1832–7.
Sunness JS, Massof RW, Johnson MA, Finkelstein D, Fine S . Peripheral retinal function in age-related macular degeneration. Arch Ophthalmol 1985; 103: 811–6.
Working Group on Night Vision. Night Vision. Washington DC, National Academy Press 1987; 335.
Mayzner MS . The research potential of a computer-based cathode-ray tube display system. Behav Res Meth Instru 1968; 1: 41–3.
Sekuler R and Armstrong R . Luminance control of a small computer CRT display: A very cheap technique. Behav Res Meth Instru 1971; 3: 48–9.
Dyer FN and Schelderup JR . Adding the dimension of colour to computer-generated displays. Behav Res Meth Instru 1973; 5: 487–9.
Polit AC . Computer generation of textures. Beh Res Meth Instru 1976; 8: 367–8.
Shapley R and Rossetto M . An electronic visual stimulator. Beh Res Meth Instru 1976; 8: 15–20.
Milkman N, Shapley R, Schick G . A microcomputer-based visual stimulator. Beh Res Meth Instru 1978; 10: 539–45.
Reed AV . Microcomputer display timing: Problems and solutions. Beh Res Meth Instru 1979; 11: 572–6.
Cavanagh P and Anstis SM . Visual psychophysics on the APPLE II: Getting started. Behav Res Meth Instru 1980; 12: 614–26.
Kelly DH . Retinal inhomogeneity. I. Spatio-temporal contrast sensitivity. J Opt Soc Am 1984a; A 1: 107–113.
Kelly DH . Retinal inhomogeneity. II. Spatial summation. J Opt Soc Am 1984b; A 1: 114–119.
King-Smith PE, Chioran GM, Sellers KL, Alvarez SL . Normal and deficient colour discrimination analysed by colour television. In Colour Vision: Physiology and Psychophysics, ed. Mollon JD & Sharpe LT, London, Academic Press, 1983; 167–172.
Hamazaki S, Yokota T, Mieno H, Koike H, Koike S, Taga M, Hamazaki J, Kikuchi G, and Matsuo H . Semi-automatic campimeter with graphic display. Docum Ophthalmol Proc Ser 1978; 19: 311–17.
Fitzke FW . Visual Psychophysics with a Video Display Controlled by a Microcomputer. J Physiol 1984; 351: 6P–0.
Ernst W, and Fitzke FW . Mapping Fine Retinal Detail by Measuring Visual Thresholds, ARVO Suppl. Inv Ophthalmol and Vis Sci 1984; 25: 144–0.
Accornero N, Berardelli A, Cruccu G, Manfredi M . Computerized video screen perimetry. Arch Ophthalmol 1984; 102: 40–1.
Hart WM and Gordon MO . Colour perimetry of glaucomatous visual field defects. Ophthalmology 1984; 91: 338–46.
Hart WM and Burde RM . Colour contrast perimetry: The spatial distribution of colour defects in optic nerve and retinal diseases. Ophthalmology 1985; 92: 768–76.
Sperling G . The description and luminous calibration of cathode ray oscilloscope visual displays. Behav Res Meth Instru 1971; 3: 148–53.
Uttal WR . Variable manufacturing characteristics of the P-15 phosphor: A warning. Behav Res Meth Instru 1973; 5: 60–0.
virsu V and Lehtio PK . A microphotometer for measuring luminance distributions on a CRT. Beh Res Meth Instru 1975; 7: 29–33.
Di Lollo V . Luminous calibration of oscilloscopic displays. Behav Res Meth Instru 1979; 11: 419–21.
Cowan WB . Discreteness artifacts in raster display systems. In Colour Vision: Physiology and Psychophysics, ed. Mollon, JD & Sharpe LT, London, Academic Press, 1983; 145–153.
Rodieck RW . Raster-based colour stimulators. In Colour Vision: Physiology and Psychophysics, ed. Mollon JD & Sharpe LT, London, Academic Press, 1983; 131–144.
Arden GB, Gunduz K, Perry S . Colour vision testing with a computer graphics system. Clin Vision Sci 1988; 4: 303–20.
Fitzke FW PhD Thesis, University of London Spatial Properties of Scotopic Sensitivity 1986.
Fitzke FW, Chuang EL, Holden AL, Kemp CM, Ernst W, Moore AT, Sharp DM, Bird AC . Fine Matrix Perimetry. (ARVO Suppl). Invest Ophthalmol Vis Sci 1987; 28: 113–0.
Chuang EL, Sharp DM, Fitzke FW, Kemp CM, Holden AL, Bird AC . Retinal Dysfunction in Central Serous Retinopathy. Eye 1987; 1: 120–5.
Fitzke FW, Holden AL, Sheen FH . A Maxwellian-view Optometer Suitable for Electrophysiological and Psychophysical Research. Vis Res 1985; 25: 871–4.
Fitzke FW . A Representational Schematic Eye in, “Modelling the Eye with Gradient Index Optics”, ed. A Hughes, Cambridge University Press, (in press).
Holden AL, Hayes BP, Fitzke FW . Retinal Magnification Factor at the Ora Terminalis: a Structural Study of Human and Animal Eyes. Vision Res 1987; 27: 1229–35.
Holden AL, and Fitzke FW . Image Size in the Fundus: Structural Evidence for Wide-field Retinal Magnification Factor. Br J Ophthalmol 1988; 72: 228–30.
Turner GS, Kemp CM, Fitzke FW, Bird AC . Rhodopsin and scotopic sensitivity in choroideremia(ARVO Suppl). Invest Ophthalmol Vis Sci 1988; 29: 314–0.
Bourne WM . ‘No statistically significant difference’: So what? Arch Ophthalmol 1987; 105: 40–1.
Seigel D . Regression. Arch Ophthalmol 1987; 105: 185–6.
Gardner MJ and Altman DS . Confidence intervals rather than P values: estimation rather than hypothesis testing. Br Med J 1986; 292: 746–50.
Wild JM and Hussey MK . Statistical concepts in the analysis of vision and visual acuity. Ophthal Physiol Opt 1986; 6: 349–51.
Ray WA and O'Day DM . Statistical analysis of multi-eye data in ophthalmic research. Invest Ophthalmol Vis Sci 1985; 26: 1186–8.
Hitchings RA . Screening for glaucoma. Br Med J 1986; 292: 505–6.
Olander KW, Higuchi B, Zimmerman TJ . Update on screening for glaucoma. Ann Ophthalmol 1987; 19: 366–7.
Committee on Vision. Emergent techniques for assessment of visual performance. Washington DC, National Academy Press, 1985: 66.
Sunness JS, Johnson MA, Massof RW, Kays DL . Wilmer fundus camera stimulator. Appl Optics 1987; 26: 1487–91.
Elsner AE, Burns SA, Lobes LA . Foveal cone optical density in retinitis pigmentosa. Appl Optics 1987; 26: 1378–84.
Greenstein V, Hood DC, Carr RE . Foveal sensitivity changes in retinitis pigmentosa. Appl Optics 1987; 26: 1385–9.
Drum B . Hybrid perimetry: a blend of static and kinetic techniques. Appl Optics 1987; 26: 1415–20.
Enoch JM, Williams RA, Essock EA, Barricks M . Hyperacuity perimetry: Assessment of macular function through ocular opacities. Arch Ophthalmol 1984; 102: 1164–8.
Williams RA, Enoch JM, Essock EA . The resistance of selected hyperacuity configurations to retinal image degradation. Invest Ophthalmol Vis Sci 1984; 25: 389–99.
Enoch JM and Williams RA . Development of clinical tests of vision: Initial data on two hyperacuity paradigms. Perception and Psychophysics 1983; 33: 314–22.
Whitaker D and Buckingham T . Theory and evidence for a clinical hyperacuity test. Ophthal Physiol Opt 1987; 7: 431–5.
Quigley HA, Dunkelberger GR, Green WR . Chronic human glaucoma causing selectively greater loss of large optic nerve fibres. Ophthalmology 1988; 95: 357–63.
Livingstone M and Hubel D . Segregation of form, movement, and depth: anatomy, physiology, and perception. Science 1988; 240: 740–9.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fitzke, F. Clinical psychophysics. Eye 2 (Suppl 1), S233–S241 (1988). https://doi.org/10.1038/eye.1988.147
Issue Date:
DOI: https://doi.org/10.1038/eye.1988.147