Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Special Focus on Particle Research
  • Published:

Comparison of PM2.5 and PM10 monitors

Abstract

An extensive PM monitoring study was conducted during the 1998 Baltimore PM Epidemiology-Exposure Study of the Elderly. One goal was to investigate the mass concentration comparability between various monitoring instrumentation located across residential indoor, residential outdoor, and ambient sites. Filter-based (24-h integrated) samplers included Federal Reference Method Monitors (PM2.5-FRMs), Personal Environmental Monitors (PEMs), Versatile Air Pollution Samplers (VAPS), and cyclone-based instruments. Tapered element oscillating microbalances (TEOMs) collected real-time data. Measurements were collected on a near-daily basis over a 28-day period during July–August, 1998. The selected monitors had individual sampling completeness percentages ranging from 64% to 100%. Quantitation limits varied from 0.2 to 5.0 µg/m3. Results from matched days indicated that mean individual PM10 and PM2.5 mass concentrations differed by less than 3 µg/m3 across the instrumentation and within each respective size fraction. PM10 and PM2.5 mass concentration regression coefficients of determination between the monitors often exceeded 0.90 with coarse (PM10–2.5) comparisons revealing coefficients typically well below 0.40. Only one of the outdoor collocated PM2.5 monitors (PEM) provided mass concentration data that were statistically different from that produced by a protoype PM2.5 FRM sampler. The PEM had a positive mass concentration bias ranging up to 18% relative to the FRM prototype.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to RON WILLIAMS.

Additional information

The U.S. Environmental Protection Agency through its Office of Research and Development funded and managed the research described here under EPA-NERL contract #68-D5-0040 to the Research Triangle Institute. It has been subjected to Agency review and approved for publication. Mention of trade names or commercial products does not constitute an endorsement or recommendation for use.

Rights and permissions

Reprints and permissions

About this article

Cite this article

WILLIAMS, R., SUGGS, J., RODES, C. et al. Comparison of PM2.5 and PM10 monitors. J Expo Sci Environ Epidemiol 10, 497–505 (2000). https://doi.org/10.1038/sj.jea.7500138

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.jea.7500138

Keywords

This article is cited by

Search

Quick links