Main

The quality of dental casts used in crown and bridgework N. Alhouri, F. McCord and P. Smith Br Dent J 2004; 197: 261–264

Comment

In this paper, the authors looked at the quality of casts used in crown and bridgework. They used a simple three point scoring system of Good (1), Fair (2), and Poor (3) based on direct observation of a number of randomly selected casts.

Both working casts and opposing casts were used in the study.

One hundred casts produced from impressions made by general dental practitioners were assessed at two commercial laboratories (50 from each), and 50 casts produced in a university dental hospital laboratory from impressions made by undergraduate dental students were also assessed, using the same criteria for all casts.

A number of interesting results were found in the study, which those involved with such work should be aware of:

The authors found no significant difference in quality between those casts prepared from impressions taken by students compared with those from practitioners. However, opposing casts demonstrated better quality where the impressions had been made by students compared with those made by practitioners. Further observations on the opposing casts from both groups were that incisal and occlusal surfaces were of better quality than buccal and lingual surfaces, and that the quality decreased from anterior to posterior regions with the exception of the anterior labial region which demonstrated the poorest quality. Overall, the quality of opposing casts was better than the working casts.

Operator consistency in use of the scoring system was verified by repeat assessments of 17 randomly selected casts one week apart. However, no mention is made of whether just one operator was involved, or whether magnification and standardised lighting and positioning were used.

In the discussion, mention is made of defects in the impressions, although the study was concerned with the resultant casts. Both should really be looked at in this type of investigation and whether this occurred here was not clear. Perhaps the most interesting result was the better quality of the opposing casts compared with the working casts. However, the authors suggest that this may be due to the fact that hydrophobic silicone materials were used for the majority of the latter whereas hydrophilic alginate was used for the former.