Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Letter
  • Published:

Pressure Calibration of a Tetrahedral Anvil Device

Abstract

THE tetrahedral anvil high-pressure device was first described by Hall1 in 1958. The pressure calibration of this device was based on the resistivity measurements of Bridgman2. Because the calibration points based on these measurements have been revised downward3, the original linear plot of sample pressure versus applied force no longer has validity. In a preliminary determination of the shape of a calibration curve based on the newer values of the calibration points, curve A (Fig. 1) was obtained. These values were obtained with an apparatus containing 7-in. hydraulic rams and triangular tungsten-carbide anvils which were 0.781 in. in edge-length. The calibration wires were inserted in silver chloride cylinders 5/32 in. in diameter which in turn were inserted in the pyrophyllite tetrahedrons, which were about 25 per cent oversize (edge length). A thick coating of iron oxide mixed with water was applied to the assembled tetrahedron before it was pressed. The use of tetrahedrons which were 35 per cent oversize caused the samples to be more distorted by the flattening of the ends of the silver chloride cylinders, as described elsewhere4. Tetrahedrons which were only 15 per cent oversize transmitted the applied force to the calibration wire less effectively. In this case about 10 per cent more ram force was necessary to attain 25 kbars on the calibration wire.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

References

  1. Hall, H. T., Rev. Sci. Instr., 29, 267 (1958).

    Article  ADS  CAS  Google Scholar 

  2. Bridgman, P. W., Proc. Amer. Acad. Arts and Sci., 81, 165 (1952).

    Article  CAS  Google Scholar 

  3. Kennedy, G. C., and LaMori, P. N., Progress in Very High Pressure Research, 304 (John Wiley and Sons, Inc., New York, 1961).

    Google Scholar 

  4. Lloyd, E. C., Hutton, U. O., and Johnson, D. P., J. Res. Nat. Bur. Stand., 63, C, 59 (1959).

    Google Scholar 

  5. Hall, H. T. (personal communication).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

GRAF, R., DEATON, B. Pressure Calibration of a Tetrahedral Anvil Device. Nature 197, 678–679 (1963). https://doi.org/10.1038/197678a0

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/197678a0

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing