Abstract
THE tetrahedral anvil high-pressure device was first described by Hall1 in 1958. The pressure calibration of this device was based on the resistivity measurements of Bridgman2. Because the calibration points based on these measurements have been revised downward3, the original linear plot of sample pressure versus applied force no longer has validity. In a preliminary determination of the shape of a calibration curve based on the newer values of the calibration points, curve A (Fig. 1) was obtained. These values were obtained with an apparatus containing 7-in. hydraulic rams and triangular tungsten-carbide anvils which were 0.781 in. in edge-length. The calibration wires were inserted in silver chloride cylinders 5/32 in. in diameter which in turn were inserted in the pyrophyllite tetrahedrons, which were about 25 per cent oversize (edge length). A thick coating of iron oxide mixed with water was applied to the assembled tetrahedron before it was pressed. The use of tetrahedrons which were 35 per cent oversize caused the samples to be more distorted by the flattening of the ends of the silver chloride cylinders, as described elsewhere4. Tetrahedrons which were only 15 per cent oversize transmitted the applied force to the calibration wire less effectively. In this case about 10 per cent more ram force was necessary to attain 25 kbars on the calibration wire.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 51 print issues and online access
$199.00 per year
only $3.90 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Hall, H. T., Rev. Sci. Instr., 29, 267 (1958).
Bridgman, P. W., Proc. Amer. Acad. Arts and Sci., 81, 165 (1952).
Kennedy, G. C., and LaMori, P. N., Progress in Very High Pressure Research, 304 (John Wiley and Sons, Inc., New York, 1961).
Lloyd, E. C., Hutton, U. O., and Johnson, D. P., J. Res. Nat. Bur. Stand., 63, C, 59 (1959).
Hall, H. T. (personal communication).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
GRAF, R., DEATON, B. Pressure Calibration of a Tetrahedral Anvil Device. Nature 197, 678–679 (1963). https://doi.org/10.1038/197678a0
Issue Date:
DOI: https://doi.org/10.1038/197678a0
This article is cited by
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.